Gateway Park Center PERKINS+WILL <br /> 810495.00 <br />12/06/18 <br />033000-6 Cast-In-Place Concrete <br />Joint locations for concrete slabs to receive a terrazzo or similar finish <br />subject to reflective cracking must be coordinated with layout of finish <br />drawings. <br />7.Comprehensive Layout Drawings: Submit for action comprehensive <br />layout drawings (a single drawing per area/element): <br />a)Drawings shall show openings in structural members, including <br />floor slab, shear walls, columns and beams. <br />b)Drawings shall consolidate the work of all trades and shall be <br />coordinated by the Contractor. <br />c)Drawings shall show concrete accessories and embedded items, <br />including fabrication details of items to be placed (exclusive of <br />reinforcement). <br />d)Submit with or prior to reinforcement and formwork submittals for <br />same element/area. <br />8.Preconstruction Survey: Submit for record. Where interface with existing <br />construction occurs, before related shop drawings are prepared survey <br />the existing construction and submit the survey prepared by a <br />professional surveyor employed by the Contractor to the Design <br />Professionals. <br />9.Survey of Flat Plate or Flat Slab Concrete Floors during construction: <br />Submit for record. Survey requirements are described on Drawings. <br />Based on survey results, SER may propose adjustments to formwork and <br />camber. <br />10.FF/FL Testing: Submit for record. Owner’s Testing Agency to test and <br />report flatness (FF), levelness (FL) prior to shoring removal. For slabs that <br />include camber, do not test for levelness (FL). Perform FF/FL testing in <br />accordance with ASTM E 1155 requirements. <br />11.Structural Repairs: Submit for action procedures, intended locations, and <br />product information. Alterations to design shall be sealed and signed by a <br />Professional/Structural Engineer licensed in the state where the project is <br />located. <br />12.Patching Defective Concrete Finishes: Submit for action procedures, <br />intended locations, and product information. <br />13.Conduit and Pipes Embedded in Concrete: Submit for action layout of <br />embedded conduit and pipes. <br />14.Hazardous Materials Notification: Submit for record. In the event no <br />product or material is available that does not contain hazardous materials <br />as determined by the Owner, a "Material Safety Data Sheet" (MSDS) <br />equivalent to OSHA Form 20 shall be submitted for that proposed product <br />or material prior to installation. <br />B.Submittal Process <br />1.Submittal of shop drawings and other submittals by the Contractor shall <br />constitute Contractor's representation that the Contractor has verified all <br />quantities, dimensions, specified performance criteria, installation <br />requirements, materials, catalog numbers and similar data with respect <br />thereto and reviewed or coordinated each drawing with other Drawings