Gateway Park Center PERKINS+WILL <br /> 810495.000 <br /> 12/06/18 <br /> <br /> <br />AUTOMATIC VERTICALLY RETRACTABLE GLASS WALL <br />08 33 36 - 4 <br /> <br /> <br />primary limit switch fail to act. This over torque sensor shall be mechanical, <br />using the motor’s torque arm in it’s over torque detection. <br />4. The lifting equipment shall use the latest in industry standards in thermal <br />protection, overload protection, quick acting fuses, etc., in order to ensure the <br />safety and reliability of the system. <br />5. The operable wall shall be equipped with an optical sensor, which shall cut <br />power to the lifting equipment if an object or person passes between the <br />emitter(s) and receiver(s). The operable wall will then automatically reverse <br />direction for approximately 3 seconds to clear the object. Regular operation of <br />the operable wall shall resume once the key switch has been released and the <br />obstruction removed. <br />2.3 PANEL CONSTRUCTION <br />A. Panels shall be architecturally flat with no bowing, oil canning, warping, waviness or <br />any other surface deformation and discontinuity. <br />B. The operable wall shall be visibly flat and rigid in the down (closed) position. <br />C. There shall be no exposed hinges, brackets and screws visible when the operable wall <br />is in the down (closed) position. All of the panel edges shall be right angled, with a <br />minimum radius not more than 1/16” (1.6mm). All of the panels shall be rectangular, <br />nominally of the same size, unless requested otherwise by the architect. Horizontal <br />joints between panels shall be no more than approximately ½” (12.7mm) wide. <br />D. The operable wall with single laminated glass panels shall not weigh more than 7.5 lbs <br />per square foot (36.6 Kg per square meters), not including the lifting equipment. <br />E. A completely functioning operable wall, tested in full accordance and compliance with <br />ASTM E90 (ISO 140-3), shall achieve, from an independent laboratory, a Sound <br />Transmission Class (STC) rating (Rw value) of not less than System STC 33 (Rw 33). <br />2.4 FOLDING MECHANISM <br />A. The hanging, folding and extension mechanism shall be, as much as possible, made <br />from structural grade aluminum extrusions and structural shapes, in order to <br />minimize the weight of the system. All wear surfaces, such as bushings, spacers, pins, <br />discs, bearings, sleeves shall be designed to function quietly and with minimum wear, <br />over the 10,000 cycle design life of the operable wall. The hangers, which fasten the <br />lifting mechanism to the support steel, shall be fabricated from steel and shall be <br />welded or bolted to the support steel supplied by others. <br />2.5 LIFTING EQUIPMENT <br />A. The lifting equipment shall be sized properly so that it can open and close the wall <br />effectively over the 10,000 cycle design life of the wall, at the minimum design speed <br />of approximately 5 to 10 vertical feet per minute (1.5 to 3 meters per minute).