Laserfiche WebLink
Gateway Park Center PERKINS+WILL <br /> 810495.000 <br /> 12/06/18 <br /> <br /> <br />DOOR HARDWARE <br />08 71 00 - 20 <br /> <br /> <br />Set: 3.0 <br />Doors: 136A, 136B <br />Description: Access Control Storage <br /> <br />6 Hinge TA2314 NRP 4-1/2" x 4-1/2" US10BE MK <br />2 Surface Bolt 988 Zinc SA <br />1 Fail Secure Lock RX 8271-24V LNMB US10BE SA <br />1 Cylinder Cylinder as Required US10BE SA <br />1 Surface Closer CPS8301 690 NO <br />2 Wall Stop 409 or 441CU US10BE RO <br />1 Threshold 2005DT PE <br />1 Gasketing 303DS x Perimeter W x H PE <br />2 Sweep 315DN PE <br />2 Astragal 303DS x H PE <br />1 Card Reader by Security Contractor OT <br />1 ElectroLynx Harness QC-C1500P MK <br />1 ElectroLynx Harness QC-CxxxP MK <br />1 Electric Power Transfer EL-CEPT 10B SU <br />1 Power Supply AQD Series as Required SU <br /> <br />Notes: All exterior doors on this project shall meet FBC standards for windstorm. The door <br />hardware specified is listed as a basis of design. If alternate hardware is proposed, please <br />provide third-party test results and compliance information to Architect. <br /> <br />Operation: <br /> <br />Doors are normally closed and locked. <br />When presented with valid credentials, card reader unlocks door. <br />During power failure, door stays locked (fail secure). <br />REX switch within lock allows egress at all times. <br />