Gateway Park Center PERKINS+WILL <br /> 810495.000 <br /> 12/06/18 <br /> <br /> <br />CERAMIC TILING <br /> 09 30 13 - 8 <br /> <br /> <br />L. Install crack isolation membrane to comply with ANSI A108.17 and manufacturer's <br />written instructions to produce membrane of uniform thickness that is bonded <br />securely to substrate. <br />3.4 INTERIOR CERAMIC TILE INSTALLATION SCHEDULE <br />A. Interior Floor Installations, Concrete Subfloor: <br />1. Ceramic Tile Installation: TCNA F125-Partial; thinset mortar on crack isolation <br />membrane. <br />a. Ceramic Tile Type: PT-1, PT-2, PP-1. <br />b. Thinset Mortar: Modified dry-set mortar. <br />c. Grout: Water-cleanable epoxy grout. <br />B. Interior Wall Installations, Masonry: <br />1. Ceramic Tile Installation: TCNA W202; thinset mortar. <br />a. Ceramic Tile Type: PT-5. <br />b. Thinset Mortar: Modified dry-set mortar. <br />c. Grout: Water-cleanable epoxy grout. <br />C. Interior Wall Installations, Metal Studs: <br />1. Ceramic Tile Installation: TCNA W244C or TCNA W244F; thinset mortar on <br />cementitious backer units over vapor-retarder membrane. <br />a. Ceramic Tile Type: PT-3, PT-4. <br />b. Thinset Mortar: Modified dry-set mortar. <br />c. Grout: Water-cleanable epoxy. <br />END OF SECTION