3/13/2020 Task Disapproval Details • EPS <br />(Remarks :FIRE,- M2Q2000,6246 <br />Cod(,? Dssirlptlon <br />REMARK ENTERED 03/02/2020 E30680 <br />1) SPECIFY THAT THIS WILL BEA CENTRAL STATION SERVICE FIRE <br />ALARM SYSTEM IN <br />2) PROVIDE A SEQUENCE OF OPERATION IN ACCORDANCE WITH <br />NFPA 72:7.2,1(4). <br />3) PROVIDE EQUIPMENT TECHNICAL DATA SHEETS IN <br />ACCORDANCE WITH NFPA <br />72 .M,1(S).302 ET -*135, SIGA•C1C1S, SIGA-TRK, PAM -1, 439•D- <br />6AW(R) <br />4);COORDINATE THE FLOOR PLAN WITH THE FIRE ALARM RISER <br />DIAGRAM IN ACCORDANCE <br />WITH NFPA 72:7.4,6 THAT INCLUDES ALL EQUIPMENT AND <br />DEVICES AND THAT SHOWS THE <br />CONNECTIONS TO ANY OTHER SYSTEM SUCH AS A BUILDING FIRE <br />ALARMSYS�E <br />Q <br />M SE� <br />If1GLE0gCESAND;NOTES; <br />5) ARRANGETHE RISER DIAGRAM TO Riftlt T THE ORDER THE <br />DEVICES.WILL ACTUALLY <br />OCCUR ON THE CIRCUITS REQUIRED BY NFPA 72:7.4;G(tt <br />6) PROVIDE ID NUMBERS FOR EACH FIRE ALARM DEVICE IN <br />ACCORDANCE WITH FAC' <br />69A48.007(1). NOTE' BATTERY CALCULATIONS AND VOLTAGE <br />DROP CALCULATIONS <br />CANNOTBEVALIDATED UNTIL EACH DEVICE IS PROPER <br />NUMBERED. <br />7) SPECIFY ON THE FLOOR PLANS THE LOCATION OF THE, <br />PRIMARY POWER DISCONNECT <br />MEANS IN ACCORDANCE WITH-NFPA 72;7:4.5(6): <br />B) SPECIFY ON THE FLOOR PLANS THE LOCATION OF ALL FIRE <br />ALARM RISERS IN <br />ACCORDANCE WITH N0PA72:7.4.5(1Q). <br />9) STATE THE. PERFORMANCE OBJECTIVE OF THE SMOKE <br />DETECTION. SYSTEM IN <br />ACCORbANCE WITH NFPA 72 17.7_.1.1, PROVIDE EITHER TOTAL <br />DETECTION SPACED IN <br />ACCORDANCEWITH 17.7.3 OR THE STATED OBJECTIVE AND <br />:17.54.,2. <br />16) PROVIDE OCCUPANT NOTIFICATION IN ACCORDANCE WITH <br />NFPA 72.18;5.5.4,'SEE . <br />SHADED A.REA$.ON FLOOR PLANS. REVISE BATTERY AND VOLTAGE <br />PROP CALCULATIONS.; <br />Iif),SPECIPY.COMMUNICATIONS EQUIPMENT AND METHODS IN <br />ACCORDANCE W- , NFPA: <br />72:26,6,6.'1F A DACT ls'USED, THEN SPECIFY THE TRANSMISSION <br />CHANNELS FOR T.HE <br />Croatad <br />MICHAEL MARCHI <br />03/02/2020 <br />F1odlNod Ralaas;ad <br />DACT IN ACCOROANCt ;WITH NFPA 72,26,6,3,2.1.4. ONLY;ONE' <br />PHONELINEIS ii <br />PERMITTEDTA SECONOGHANNLLlUTaBE�AbF�E�WJ� A eW(¢;ellitlelrR�d1 Will <br />o���h ^g r p t� t n.vp k.S `F0 a <br />.�� <br />��T px�+�9R��A±+bEo�iih�di)re�til�ee�n , <br />s <br />L x. ESQ ##a. L ._ �• , _,��:�;, <br />12) AtitdDDEREFERERCES LISTED IN COMMENT$ ARE FROM THE'. <br />FLORIDA FIRE, <br />PREVENTION CODE, 6TH EOITION AND THE INCORPORATED NFPA. <br />CODESAND STANDARDS; <br />THE FLORIDAADMINISTRATIVE CODE; AND MIAMI•DAbE COUNTY` <br />CODECHAPTER 14, FIRE <br />PREVENTION. <br />13) P ROVIDE A WRITTE N RESPONSE ADDRESSING EACH <br />COMMENT AND SPECIFYING THE <br />SHEET WHERE CHANGES.WERE MADE. PROVIDE NEW SHEETS <br />FOR ALL CORRECTIONS AND <br />CHANGES. ALL CORRECTIONS AND CHANGES MUST BE CLOUDED <br />DISAPPROVED <br />hllps:IIWY v,m1on11dado.govlAppORSRII' PSC'ollellplanrevldWldlsapprovollprocos9IM20200002461trado/X119708 1/2 <br />