<br />City of Sunny Isles Beach |Request for Proposal No. 22-04-01 35 <br /> <br />The cable shall exhibit no flow (drip or leak) for 24 hours at 80°C. The weight of any compound that drips <br />from the sample shall be less than 0.05 grams (0.002 ounce). A representative sample of cable shall be <br />tested in accordance with TIA/EIA-455-81B (FOTP-81), "Compound Flow [Drip] Test for Filled Fiber Optic <br />Cable". The test sample shall be prepared in accordance with method A. <br />Crush resistance of the finished fiber-optic cables shall be 220 N/cm applied uniformly over the length of <br />the cable without showing evidence of cracking or splitting when tested in accordance with TIA/EIA-455- <br />41 (FOTP-41), "Compressive Loading Resistance of Fiber Optic Cables." The 220 N/cm (125 lbf/in) load <br />shall be applied at a rate of 2.5 mm (0.1 in) per minute. The load shall be maintained for a period of 1 <br />minute. The load shall then be decreased to 110 N/cm (63 lbf/in). Alternatively, it is acceptable to remove <br />the 220 N/cm (125 lbf/in) load entirely and apply the 110 N/cm (63 lbf/in) load within five minutes at a <br />rate of 2.5 mm (0.1 in) per minute. The 110 N/cm (63 lbf/in) load shall be maintained for a period of 10 <br />minutes. Attenuation measurements shall be performed before release of the 110 N/cm (63 lbf/in) load. <br />The change in attenuation shall not exceed 0.4 dB during loading at 1550 nm for single-mode fibers and <br />1.0 dB during loading at 1300 nm for multimode fiber. The repeatability of the measurement system is <br />typically 0.05 dB or less. No fibers shall exhibit a measurable change in attenuation after load removal. <br />The cable shall withstand 25 cycles of mechanical flexing at a rate of 30 ±1 cycles/minute with a sheave <br />diameter not greater than 20 times the cable diameter. The cable shall be tested in accordance with Test <br />Conditions I and III of TIA/EIA-455-104A (FOTP-104), “Fiber Optic Cable Cyclic Flexing Test.” The <br />magnitude of the attenuation change will be within the repeatability of the measurement system for 90% <br />of the test fibers. The remaining 10% of the fibers will not experience an attenuation change greater than <br />0.1 dB at 1550 nm. The repeatability of the measurement system is typically ± 0.05 dB or less. The cable <br />jacket will exhibit no cracking or splitting when observed under 5X magnification. <br />Impact testing shall be conducted in accordance with TIA/EIA-455-25B (FOTP-25) "Repeated Impact <br />Testing of Fiber Optic Cables and Cable Assemblies." The cable shall withstand 20 impact cycles. The <br />magnitude of the attenuation change will be within the repeatability of the measurement system for 90% <br />of the test fibers. The remaining 10% of the fibers will not experience an attenuation change greater than <br />0.1 dB at 1550 nm. The repeatability of the measurement system is typically ± 0.05 dB or less. The cable <br />jacket will not exhibit evidence of cracking or splitting at the completion of the test. <br />Using a maximum mandrel and sheave diameter of 560 mm, the finished cable shall withstand a <br />longitudinal tensile load of 2700 N (608 lbs.) applied for one hour (using "Test Condition II" of the test <br />plan). The test shall be conducted in accordance with TIA/EIA-455-33 (FOTP-33), "Fiber Optic Cable Tensile <br />Loading and Bending Test." The measured fiber tensile strain shall be < 60% of the fiber proof strain. The
The URL can be used to link to this page
Your browser does not support the video tag.