6ENEIRAL NOTES:
<br />SYMBOL LEGEND:
<br />INDEX OF DRAWINGS:
<br />1. IN THE EVENT THAT DISCREPANCIES OR AMBIGUITIES AND/OR OMISSIONS FROM THE SPECIFICATIONS OR DRAWINGS ARE FOUND, OR SHOULD
<br />THERE BE DOUBT A5 TO THEIR MEANING, THE ARCHITECT SHALL BE NOTIFIED IN ORDER TO PROVIDE A WRITTEN GLARIFIGATION.o'
<br />2. ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COMMON USE. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION.
<br />A 3.0 INDICATE5 EX15T. DATUM POINT
<br />L-swNUMBER
<br />INDICATES NEW DATUM POINT INDICATES NORTH ARRON
<br />DL`iGIPUNELM
<br />DING. #
<br />DMAPT
<br />A `
<br />q N
<br />o
<br />* o
<br />COVER ��
<br />•
<br />•
<br />3. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
<br />A-0.1
<br />INDEX OF DRAININ65, 5COPE OF WORK, LEGENDS, CODE5, ADA REVIEA, GENERAL NOTE5
<br />•
<br />•
<br />EQUIPMENT TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUCTION
<br />CONTRACT, AND A5 REQUIRED BY CONRACTOR, PROJECT SPECIFICATIONS, FBG AND OSHA.
<br />4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER TRADES AND THEIR WORK TO ENSURE
<br />COMPLIANCE WITH THE DRAWING5 AND SPECIFICATIONS.
<br />O INDICATES NEN DOOR MARK
<br />A AA
<br />XO INDICATES NEN NINOONMARK
<br />-
<br />CIVIL ENGINEERING
<br />NOT APPLICABLE
<br />5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD BEFORE COMMENCING ANY PORTION OF THE WORK AND
<br />SHALL NOTIFY THE ARCHITECT IN WRITING IMMEDIATELY IF THERE ARE ANY DISCREPANCIES AND/OR DEVIATIONS FROM THE DRAWINGS OR AS
<br />REQUIRED IN ORDR TO ACCOMODATE EXISTING CONDITIONS. COMMENCEMENT OF WORK SHALL CONSTITUTE FULL ACCEPTANCE OF SITE
<br />INDICATES AREA OF ENLARGED PLAN
<br />- INDICATES NEW LOUVER MARK i DETAIL AND SHEET LOCATION
<br />XX INDICATES PARTITION TYPE MARK J
<br />LANDSCAPE AGHITEGTURE
<br />CONDITIONS.
<br />COLUMN SYMBOL AND camRLME5
<br />NOT APPLICABLE
<br />6. THE CONTRACTOR SHALL VERIFY 5IZES AND LOCATIONS OF ALL OPENING5 FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH
<br />5UB-CONTRACTOR5, A5 WELL A5 5HOP DRAWING5 A5 APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
<br />PROPERTY LINE
<br />-i. ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE
<br />ORDINANCES AS TO APPLICATION AND USE.
<br />INDICATES REV15ION CLOUD,
<br />n MARK AND NUMBER FLOOR PLAN SYMB01.5:
<br />� X
<br />AGHITECTURE
<br />A-2.00
<br />EXISTING CONDITIONS /DEMOLITION /STAGING PLAN AND ELFI(A110N5
<br />•
<br />•
<br />8. PROVIDE DIELECTRIC INSULATION BETWEEN ALL DISSIMILAR METALS
<br />q. M.E.P. SUB-CONTRACTOR(S) ARE RESPONSIBLE FOR REVIEWING ALL DRAWINGS RANGS INCLUDING ARCHITECTURAL EQUIPMENT/AGGE55ORY FLOOR
<br />PLANS AND SCHEDULES BEFORE 5UBMITTING FINAL BID. GENERAL CONTRACTOR 15 RESPONSIBLE FOR ALL EQUIPMENT AND M.E.P.
<br />REQUIREMENTS REQUESTED ONTHE DRAWWI
<br />DRAWINGS TO BE INSTALLED. M.E.P. SUB -CONTRACTORS BID SHALL BE BASED ON ALL DRANG5.
<br />10. GENERAL CONTRACTOR 15 RESPONSIBLE FOR THE TOTAL SCOPE OF THE WORK INCLUDING COORDINATION OF ALL TRADES. IT 15 THE
<br />INDICATE5 NEN 5" MA50NRY WALL, REFER
<br />BREW, LINE INDICATES EXTERIORANTERIORELEVATION TO FLOOR PLANS
<br />A5.0 - OR- �p MARK AND DIRECTION
<br />'� INOIGATE5NEN INTERIOR 5TUOPARTITION,
<br />`+' INDICATES EX15T. VERTICAL ELEVATION MARK REFER TO FLOOR PLAN5
<br />EL. +X'-XDESIGNATION
<br />A-2.01
<br />RENOVATION FLOOR PLANS, REFLECTED CEILING PLAN, ROOF PLAN AND PROPOSED EXTERIOR ELEVATIONS
<br />•
<br />•
<br />A-4.00
<br />BUILDING AND YVALJ. SECTIONS
<br />•
<br />A-500
<br />PROPOSED INTERIOR ELEVATIONS
<br />•
<br />A400
<br />DOOR 5CHEDULE, FIN15H SCHEDULE, DOOR DETAIL5
<br />•
<br />RESPONSIBILITY OF THE CONTRACTOR THAT ALL M.E.P. SUB-CONTRAGTORS REVIEW ALL DRAWING5 BEFORE BIDDING THE WORK IN -LIEU OF
<br />ONLY REVIEWING THE DRWING5 OF THEIR RESPECTIVE TRADE.
<br />T INOICATE5 NEW INTERIOR 5TUD PARTITION
<br />2nd' FLOOR INDICATES NEN VERTICAL ELEVATION MARK A6.0 INDICATES BUILDING SECTION TAG W
<br />50UND ATTENUATION BLANKET5,
<br />11. SINGE THE WORK TO BE DONE INVOLVES EXISTING SITE CONDITIONS, GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT, IN WRITING,
<br />EL. + X' -X
<br />SHEET NUMBER REFS TO FLOOR PLAN5
<br />OF ANY AND ALL CONFLICTS BETWEEN EXISTING SITE CONDITIONS AND GONTRAGT DOCUMENTS.
<br />DW
<br />12. ALL SECTIONS AN/OR DETAILS NOTED A5 "TYPICAL" ON PLANS MAY NOT BE NOTED AT EACH APPLICABLE CONDITION, HOWEVER, THEY
<br />MAY BE USED MORE THAN ONCE.
<br />GRADE
<br />EL + X -X" INDICATES EXIST. SPOT E.EVAl10N MARK SECTION DESIGNATION INDICATE5 POURED CONCRETE COLUMN,
<br />REFER TO FLOOR PLAN5 AND 5TRUCTURAL
<br />EL. + X-X"INOIGATE5 MALL 5EGTION TAG ONG5.
<br />INDICATES NDN SPOT ELEVATION MARK �•0
<br />13. THESE DRAWI1465 ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME.
<br />SHEET NUMBER INDICATE5 EX15T. MA50NRY HALL TO BE
<br />�
<br />- - - - - REMOVED, REFER TO DEMO PLANS
<br />14. CONTRACTOR MUST FOLLOW PROJECT SPECS. FOR ALL MATERIALS B INSTALLATION ON THI5 PROJECT UNLE55 OTHERN15E NOTED IN
<br />THESE DRAWINGS. IN THE ABSENCE OF A WRITTEN SPECIFICATIONS MANUAL THE INFORMATION CONTAINED WITHIN THESE DRAWINGS SHALL
<br />BE CONSIDERED THOSE SPECFIGATIONS.
<br />jy INDICATE ROOM NAME (TYP. FLR.)
<br />/ INDICATES DETAIL MARK
<br />/)0( INDICATE ROOM NUMBER (TYP. FLR.) \ AND SHEET LOCATION INDICATE5 EX15T. INTERIOR STUD PARTITION
<br />, - - - - - TO BE REMOVED, REFER TO DEMO PLANS
<br />15. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR THE SAFETY AND SECURITY OF ALL AREAS AFFECTED BY CONSTRUCTION, THIS RESPONSIBILITY
<br />EXTENDS FROM THE BEGINNING OF CONSTRUCTION (BUILDING PERMIT) THROUGH TO COMPLETION OF CONSTRUCTION (FINAL PAYMENT TO
<br />CONTRACTOR), 4 HOURS A DAY -7 DAYS A WEEK.
<br />16. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR THE COMPLETE SET OF CONSTRUCTION DOCUMENTS. DIVISION OF DISCIPLINES 15 INTENDED
<br />FOR THE DESIGNER'5 BENEFIT WHILE PREPARING THE PLANS AND NOT FOR EITHER PRIGING OR WORK PERFORMANCE. CONTRACTOR 15
<br />RESPONSIBLE FOR PRVIDING SERVICES REQUIRED TO OPERATE ALL TEMPORARY EQUIPMENT. IF 6AP5 EXIST, THE GENERAL CONTRACTOR 15
<br />RESPONSIBLE FOR REQUESTING THE INFORMATION DURING THE PRICING PHASE. AT THEIR OWN EXPENSE AND FOR THE PROTECTION OF THIS
<br />CONCEPT, THE ARCHITECT RECOMMEND THAT THE GENERAL CONTRACTOR MAKE COMPLETE SETS AVAILABLE TO SUB-GONTRACTORS FOR
<br />PRICING/BIDDING PURPOSES.
<br />1-I. THESE DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT OF SYSTEMS AND WORK INCLUDED IN CONTRACT.
<br />5UB-CONTRACTOR SHALL FOLLOW DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK
<br />WILL BE INSTALLED, AND MAINTAINMAXIMUM HEADROOM AND SPACE CONDITIONS AT AREAS WHERE HEADROOM OR SPACE CONDITIONS
<br />APPEAR INADEQUATE, THE ARCHITECT SHALL BE NOTIFIED BEFORE PROCEEDING WITH FABRICATION AND INSTALLATION. IF DIRECTED BY THE
<br />ARCHITECT, THE SUB-GONTRAGTOR SHALL, WITHOUT EXTRAGHARGE, MAKE REASONABLE MODIFICATIONS IN LAYOUT A5 NEEDED TO PREVENT
<br />CONFLICT WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK WHERE VARIENCE5 OCCUR BETWEEN DRAWIN65 AND
<br />SPECIFICATIONS, OR WITHIN EITHER DOCUMENT ITSELF, THE ITEM OR ARRANGEMNT OF BETTER QUALITY, GREATER QUANTITY OR HIGHER COST
<br />SHALL BE INCLUDED IN PRICE. THE ARCHITECT SHALL DECIDE ON ITEM AND MANNER IN WHIGH THE WORK SHALL BE INSTALLED.
<br />i
<br />.
<br />,
<br />G
<br />15. THE CONTRACTOR SHALL PROVIDE ANY LIFE SAFETY ITEMS THAT SHALL BE REQUIRED BY APPLICABLE CODES AS A RESULT OF THE
<br />RENOVATION AT NO ADDITIONAL COST TO THE OWNER.
<br />1G. CONTRACTOR SHALL MAINTAIN ALL LIFE SAFETY SYSTEMS AND PATH OF EGRESS TRAVEL THROUGHOUT THE DURATION OF PROJECT
<br />CONSTRUCTION. IF PATH OF EGRE55 I5 REDUCED OR BLOCKED AT ANY TIME, CONTRACTOR SHALL SUBMIT FOR APPROVAL TO A/E AN
<br />ALTERNATE SOLUTION PRIOR TO IPLEMENTATION.
<br />r
<br />20. IF FIRE ALARM SYSTEM 15 OFFLINE MORE THAN 4 HRS. WHEN FACILITY 15 IN USE, CONTRACTOR SHALL PROVIDE FIRE WATCH.
<br />21. CONTRACTOR SHALL NOTIFY THE OYNNER'5 REPRESENTATIVE AND A/E OF ANY EXI5TING ALARM SUPERVISION, OR TROUBLE CONDITION IN
<br />THE FIRE ALARM PANEL PRIOR TO COMMENCING WORK ON THE FIRE ALARM SYSTEM. ALARM PANEL SHALL BE CLEARED OF ALL TROUBLES
<br />PRIOR TO COMMENCINGWORK.
<br />MZJMT )IMANITY MAP
<br />ELECTRICAL ENGINEERING
<br />ABBR&LAMONS LEGEND:
<br />E-1.00
<br />ELECTRICAL PLANS, GENERAL NOTE5, LEGENDS, 1.I6HTIN6 5GHEDULE
<br />•
<br />THE FOLLOWING 15 A L15T OF ABBREVIATIONS THAT MAY APPEAR WITHIN THI5 5ET OF GON5TRUCTION
<br />DRANING5:
<br />R PROPERTY LINE
<br />CL CENTER LINE
<br />+/ PLUS OR MINUS
<br />8 AND
<br />ACT AEOU5TIGAL CEILING TILE
<br />ADAAG ADA AGCE55IBILITY 6UIDELINE5
<br />ADH ADHESIVE
<br />ADJ ADJU5TIBLE
<br />ADMIN. ADMINISTRATION
<br />ADA AMERIGAN5 WITH DISABILME5 ACT
<br />AFF ABOVE FINISHED FLOOR
<br />ALT ALTERNATE, ALTERNATIVE
<br />ALUM ALUMINUM
<br />ANOD. ANODIZED
<br />APPROX. APPROXIMATELY
<br />ARCH ('L) ARCHITECT, (ARCHITECTURAL)
<br />A5 IND. A5 INDICATED
<br />BITUM BITUMINOUS
<br />BLDG BUILDING
<br />BRZ BRONZE
<br />FBG FLORIDA BUILDING CODE
<br />F.F.E. FIN15H FLOOR ELEVATION
<br />FO FLOOR DRAIN
<br />FE FIRE EXTINGUI5HER
<br />FEG FIRE EXTINGUISHER CABINET
<br />FHG FIRE HOSE CABINET
<br />FIN FINISH
<br />FLR. FLOOR (INC)
<br />GA GAUGE
<br />GALV GALVANIZED
<br />GBOX &UTTERBOX
<br />GG GENERAL CONTRACTOR
<br />GWB GYPSUM NALLBOARD
<br />HG HANDICAPPED
<br />HON HARDNARE
<br />HOW HARDWOODSECT
<br />HUN. MTL. HOLLOW METAL
<br />HORIZ. HORIZONTAL
<br />HVAC HEAT'GNENTILATION/AIR CONO.
<br />P LAM PLA5TIE LAMINATE
<br />PNL PANEL
<br />PWD PLYWOOD
<br />QT QUARRY TILE
<br />RD ROOF DRAIN
<br />RE RAIL EXTEN51ON
<br />REF REFRIGERATOR
<br />REINF REINFORCEMENT
<br />READ REQUIRED
<br />RM ROOM
<br />RO ROUGH OPENING
<br />R.O.W. RIGHT OF NAY
<br />SGHED SCHEDULE
<br />SECT 5EGTION
<br />5F 5QUARE FOOT
<br />5HT SHEET
<br />5HNR 5HONER
<br />51M 51MILAR
<br />T
<br />; , �
<br />rti
<br />'+ r•�
<br />� _ �
<br />.' f
<br />r t nt�
<br />��
<br />i Z
<br />..•, Q e ' 4 I
<br />O' .
<br />�'
<br />- ;a3�
<br />MZJMTSMIFIC ENLAR6ED MAP
<br />PLUMBING ENGINEERING
<br />P-0.00
<br />PLUMBING GENERAL NOTES, LEGEND, SCHEDULES AND DETAILS
<br />•
<br />P-1.00
<br />PLUMBING DEMO PLAN AND NEW PLANS
<br />•
<br />STRUCTURAL ENGINEERING
<br />5-2.01
<br />RE5TROOM FACILITY FOUNDATION AND GROUND FLOOR ROOF PLANS
<br />•
<br />5-3.01
<br />STRUCTURAL GENERAL NOTES, SCHEDULES AND DETAILS
<br />•
<br />5-3.02
<br />5TRUGTURAL GENERAL NOTES, SCHEDULES AND DETAILS•
<br />5-4,01
<br />RESTROOM PAUCITY SECTIONS
<br />•
<br />GAB CABINET
<br />GG CORNER GUARD
<br />GJ CONTROL JOINT
<br />IN INGHE5
<br />IN5UL INSULATION
<br />INT INTERIOR
<br />5FE65 5PEGIFICATION5
<br />5PBK 5PLA5HBLOCK
<br />55 STAINLESS STEEL
<br />5TG SOUND TRAN5MI5510N GOEFFIGEINT
<br />APLIverkw&E Com:
<br />Of FKALITY /SCOPE OF WORK:CP
<br />CONTROL POINT
<br />JB JUNCTION BOX
<br />5TO 5TANDARD
<br />ELG CEILING
<br />GLR CLEAR
<br />JT JOINT
<br />5TOR STORAGE
<br />5TL STEEL
<br />1. FLORIDA BUILDING CODE, 7th. EDITION (2020) (INGLUDING ALL ACLE55ORY AND TRADE CODES).
<br />THE 5ITE 15 AN EXI5TIN6 CITY OF SUNNY I5LE5 BEACH ACCESS PUBLIC RESTROOM FACILITY. THE SCOPE OF WORK FOR THI5 PROJECT INCLUDES:
<br />GMU CONCRETE MASONRY UNIT
<br />COL COLUMN
<br />GONG CONCRETE
<br />LAM LAMINATED
<br />LAV LAVATORY
<br />LF LINEAR FEET
<br />5TRUGT 5TRUGTURAL
<br />5U5P 5U5PENDED
<br />2. FLORIDA FIRE PREVENTION CODE, 7th. EDITION (2020)
<br />3. THE AMERICANS WITH DISABILITIES ACT 2010
<br />• PARTIAL DEMOLITION OF EXISTING STRUCTURE.
<br />• RENOVATION OF EXI5TIN6 SINGLE U5ER RESTROOM FACILITIES, INCLUDING ADA ACCESSIBILITY, FIXTURE REPLACEMENT (RESET IN CURRENT L.00ATIONS), NEIN INTERIOR FINISHES
<br />CANT GONTINUOU5
<br />T$G TONGUE S GROOVE
<br />AND TOILET ROOM ACCESSORIES.
<br />GPT CARPET
<br />MA5 MA50NRY
<br />TEL TELEPHONE
<br />4. FLORIDA BUILDING CODE - ACCESSIBILITY -7th, EDITION (2020)
<br />GT CERAMIC TILE
<br />MAIL MATERIAL
<br />THK 7HIGKNE55
<br />• EXTERIOR / INTERIOR STRUCTURAL REPAIRS TO BRING STRUCTURE UP TO 2020 FLORIDA BUILDING CODE, NEN ROOF TRUSSES, NEN ROOFING AND VENTILATION.
<br />MEGH MECHANICAL
<br />TYP TYPICAL
<br />DEMO DEMOLI5H, DEMOLITION
<br />DET DETAIL
<br />OF DRINKING FOUNTAIN
<br />DIA DIAMETER
<br />MO MA50NRY OPENING
<br />MNTD MOUNTED
<br />MTL METAL
<br />UG UNDERCUT
<br />UL UNDERWRITER'S LABORATORY
<br />UR URINAL
<br />• A550GIATED MECHANICAL, ELECTRICAL AND PLUMBING 5Y5TEM5 NECE55ARY FOR SCOPE ABOVE
<br />DIM DIMEN51ON
<br />ON DONN
<br />05+56 DOWN SPOUT d 5PLA5HBLOGK
<br />DTL DETAIL
<br />DWG DRANING
<br />N/A NON - APPLICABLE
<br />NIG NOT IN CONTRACT
<br />NOM NOMINAL
<br />NT5 NOT TO SCALE
<br />VET VINYL COMPOSITION TILE
<br />VERT VERTICAL
<br />VE5T VE5TIBULE
<br />VIF VERIFY IN FIELD
<br />STATEMENT Of COMPLIANCE:
<br />EA EACH
<br />OA OVERALL
<br />OG ON CENTER
<br />VNG VINYL HALL COVERING
<br />TO THE BEST OF OUR KNOB EDGE, THESE PRAIVIN65 ARE COMPLETE AND COMPLY WITH THE FLORIDA BUILDING CODE, 7th. EDITION
<br />(2020) AND FLORIDA FIRE PREVENTION CODE, 7TH. EDITION (2020).
<br />EL ELEVATION
<br />OD OUT5IDE DIAMETER
<br />WG NATER CL05ET
<br />ELEG ELECTRIC (AL)
<br />ELEV ELEVATOR
<br />EQ EQUAL
<br />OPNG OPENING
<br />OPP OPP0517E
<br />ND WOOD
<br />NGT WEIGHT
<br />ACGE55IBILITY STATEMENT: THESE CON5TRXTION DOCUMENTS ARE COMPLIANT WITH THE REOL11REdENT5 OF THE ADA,
<br />AND FLORIDA BUILDING GORE - ACCESSIBILITY, WHERE APPLICABLE.
<br />EQUIP EQUIPMENT
<br />RN31DRIGUEZ
<br />ARCHITECTS
<br />INCORPORATED
<br />2121 PONCE DE LEON BLVD, STE.1010
<br />CORAL GABLES, FL. 33134
<br />TEL: (305) 448-3373
<br />FAX: (305) 448-3374
<br />A R -- 10099
<br />J
<br />J
<br />REVIBION5:
<br />GHEGKED BY:
<br />100% ISSUE DATE:
<br />MAR
<br />04/29/2022
<br />DRAWN BY:
<br />PROJECT NO.
<br />DM5
<br />2124
<br />SHEET.
<br />A-0.1
<br />OF 5HEET5
<br />
|