Laserfiche WebLink
BID TITLE: BID 19 -17 -12 -HR BID NUMBER: ROOFING MAINTENANCE & REPAIRS <br />SECTION 07920 — SEALANTS AND CAULKINGS <br />(Continued) <br />PART 3 — EXECUTION (Continued) <br />3.04 CLEANING <br />A. As work progresses, immediately remove sealant that may <br />accidentally flow onto adjacent surfaces, using solvent and <br />cleaners recommended by sealant manufacturer. <br />B. At completion, carefully check and repair damaged joints. <br />3.05 SCHEDULE <br />A. EXTERIOR AND INTERIOR SEALANTS: <br />1. Significant movement (+25% or -25% joint <br />movement capability): Vertical or inclined joint <br />such as panel, coping, control and expansion <br />joints, precast planks, prestressed concrete <br />joints: Sealant Reference #1, 3. <br />2. Minimal movement (+25% or -50% joint <br />movement capability): Vertical or inclined <br />joints such as perimeters of doors, windows, <br />wall penetrations: Sealant Reference #1, 2, 3. <br />3. Paving (requiring fuel resistant sealants): Sealant Reference #5. <br />B. GLAZING SEALANTS: <br />1. Structural: <br />Sealant Reference #4. <br />2. Nonstructural: <br />Sealant Reference #2, 3, 4. <br />C. INTERIOR: <br />1. General interior, under door and window bucks: Sealant <br />Reference <br />#7. <br />2. Special: <br />a. Toilet rooms: <br />b. Exposed acoustical: Sealant Reference #7 <br />C. Nonexposed acoustical: Sealant Reference #8 <br />END OF SECTION 07920 <br />Revised 6/27/18 Page 29 <br />