64E-11.008 Other Facilities and Operations. <br />(1) Floors – The floor surfaces in kitchens and all the rooms and areas in which food is stored or prepared, utensils are washed <br />or stored, walk-in refrigerators, garbage and rubbish storage areas or rooms and toilet, dressing and locker rooms shall be of <br />smooth, nonabsorbent material and so constructed as to be easily cleanable. The use of anti-slip floor covering materials is <br />permitted in areas where necessary for safety reasons. Floor drains shall be provided in accordance with provisions of the <br />applicable plumbing authority in all rooms where floors are subjected to flush or flood type cleaning or where normal operations <br />release or discharge water or other liquid waste onto the floor. Such floors shall be graded to effectively drain. Mats or duckboards, <br />if used, shall be so constructed as to facilitate being easily cleaned and shall be kept clean. The floor surfaces in all interior and <br />exterior areas where food is served shall be of such construction and finish as to be easily cleanable. Carpeting, if used on floors of <br />interior dining rooms, shall be kept in good repair and shall be cleaned by dustless methods. All floors shall be kept clean and in <br />good repair. Sawdust, wood shavings, peanut hulls and similar materials shall not be permitted on the floors of a food service <br />establishment. In all new or extensively remodeled establishments utilizing concrete, terrazzo, ceramic tile or similar flooring <br />materials, the junctures between walls and floors shall be coved and sealed. Installation of exposed horizontal utility lines and <br />pipes on the floor is prohibited. <br />(2) Walls and ceilings – All walls and ceilings including doors, windows, skylights, screens and similar closures shall be kept <br />clean and in good repair. The walls of all food preparation, utensil washing and handwashing rooms or areas shall have smooth, <br />easily cleanable surfaces and shall be washable up to the highest level reached by splash or spray. Concrete or pumice blocks used <br />for interior wall construction shall be finished and sealed to provide an easily cleanable surface. Studs, joists and rafters shall not <br />be left exposed in walk-in refrigerating units, in food preparation or washing areas or toilet rooms. If exposed in other rooms or <br />areas, they shall be suitably finished and all surfaces shall be kept clean and in good repair. Sheet metal, plastic or other covering <br />materials, if used, shall be closed at all joints and shall be sealed to the wall or ceiling. Acoustical materials may be used on <br />ceilings, provided ventilation is adequate to minimize grease and moisture absorption. Light fixtures, fans, hoods and other <br />equipment and materials attached to walls or ceilings shall be kept clean. Exposed utility service lines and pipes shall be installed <br />in a way that does not obstruct or prevent cleaning of the walls and ceiling. Utility service lines and pipes shall not be <br />unnecessarily exposed on walls or ceilings in walk-in refrigerating units, food preparation areas, equipment washing and utensil <br />washing areas, toilet rooms and vestibules. <br />(3) Lighting – All areas in which food is stored or prepared, utensils washed or stored, toilet, dressing and locker rooms, <br />handwashing areas and garbage and rubbish storage areas shall be well lighted. At least 20 foot candles of light shall be provided <br />on all working surfaces and at least 10 foot candles shall be provided on all other surfaces and equipment in food storage, food <br />preparation, utensil washing and handwashing areas and in toilet rooms. At least 10 foot candles of light at a distance of 30 inches <br />from the floor shall be required in dining rooms and all other areas during cleaning operations. Effective shields, sleeves, coatings, <br />or covers shall be provided for all artificial lighting fixtures and infrared heat lamps located over, by, or within food storage, <br />preparation and display facilities where food is opened or exposed. <br />(4) Ventilation – All rooms in which food is stored, prepared or served, utensils are washed, toilet, dressing and locker rooms <br />and garbage storage areas shall be well ventilated. Obnoxious odors, fumes and vapors shall be effectively vented to the outside <br />air. Ventilation hoods and devices shall be designed to prevent grease and condensate from dripping into food or onto food-contact <br />surfaces. Filters, where used, shall be readily removable for cleaning unless designed to be cleaned in place. Ventilation systems <br />shall comply with applicable fire prevention requirements and shall discharge in such a manner as not to create a nuisance. Intake <br />and exhaust air ducts shall be maintained to prevent the entrance of dust, dirt and other contaminating materials. <br />(5) Dressing rooms and lockers – Adequate facilities shall be provided for the orderly storage of employees’ clothing and <br />personal belongings. Where employees routinely change clothes within the establishment, one or more dressing rooms or <br />designated areas shall be provided for this purpose. Such rooms or areas shall be located outside the food storage, preparation and <br />serving areas and utensil washing and storage areas. Lockers or other suitable storage facilities shall be provided. Dressing areas <br />and lockers shall be kept clean and orderly. <br />(6) Housekeeping – All parts of the establishment and its premises shall be kept neat, clean and free of litter and rubbish. <br />Cleaning operations shall be conducted in such a manner as to minimize contamination of food and food-contact surfaces. Vacuum <br />cleaning, wet cleaning or other dustless methods shall be used for cleaning floors, walls and ceilings; provided, that dust-arresting <br />sweeping compounds and push brooms may be employed for floors. All such cleaning, except emergency floor cleaning, shall be <br />done during periods when the least amount of food is exposed, such as after closing and between meals. At least one utility sink or <br />curbed cleaning facility with a floor drain shall be provided and used for the cleaning of mops or similar wet floor cleaning tools <br />and for the disposal of mop water or similar liquid wastes. The use of lavatories, utensil washing or equipment washing, or food <br />preparation sinks for this purpose is prohibited. Each utility sink or curbed cleaning facility shall be supplied with hot and cold <br />water under pressure. Maintenance and cleaning tools such as brooms, mops, vacuum cleaners and similar equipment shall be <br />maintained and stored in a way that does not contaminate food, utensils, equipment or linens and shall be stored in an orderly <br />manner. Soiled cloths, linens, aprons, coats and other uniform apparel shall be kept in suitable containers until removed for