Laserfiche WebLink
°ZC <br />SOLID PLATE <br />TOP OF BAFFI <br />POLLUTION RETARDANT <br />CATCH BASIN OR MANHOLE <br />FINISHED GRADE FINISHED GRADE NOTE: <br />SEE GRADING PLANS SEE GRADING PLANS i. FRENCH DRAIN TO BE IN ACCORDANCE WITH <br />DADE COUNTY STANDARD DETAILS SD -i.1 <br />LATEST REVISION MARCH 12, 1992. <br />• i0 -i" X i° SELECT BACKFILL o z o z SELECT BACKFILL 2. WOVEN PLASTIC FILTER FABRIC (AT EACH SIDE, <br />SELECT FILL GALV., STEEL OR _ <br />LEVELING COURSE ALUM. WIRE MESH. 30+ ROOFING FELT ` '" z ={ z TOP AND BOTTOM) SHALL BE USED IN SANDY OR <br />[OVER PIPE END] 30+ ROOFING FELT FILLED AREAS. <br />5'X VARIES �- is i OR STEEPER <br />(Ape ` 3. WASH DOWN THE BALLAST ROCK WITH CLEAN WATER <br />AIR PEA ROCK ? �' Z PEA ROCK � AFTER ROCK HAS BEEN PLACED TO THE PROPER <br />ELEVATION TO ALLOW FOR INITIAL SETTLEMENT THAT <br />BAFFLE WATER TABLE MAY OCCUR. ADD ADDITIONAL BALLAST ROCK TO RESTORE <br />EL - 2. 00 NGVD <br />NO SLOTS OR i' -0° [OCTOBER HIGH) i' -O° ROCK TO THE PROPER ELEVATION IN ACCORDANCE WITH <br />PERFORATIONS IN. COV I ��„Q MIN. THE DETAILS. <br />''�b CLEAR <br />cc z • • • • • • • • • • • • • • . .. . • .... ... .. ... .... ; ; + i0 -i" X i" 4. FOR PERFORATED CMP PIPE JOINT ARE TO BE BANDED, <br />% " . :.. :..:.........:. ...... ...:cx �bi.''.:.. .. .... .. ':...... ii:.:'. :.: ::.. �:..' a . GALV. STEEL R <br />.......... .... .. ..... <br />z ............... ....... ........ ...... i ....1. Z . .... . " ':.':::.. o 'o ... .. O BUT NOT GASKETED. <br />ERFORATED i 5 HOPE (• , • •z• • • •'• • ALUM. WIRE MESH. <br />.. ' ... ..... .:..:.. :: J0 i.IV'C: C ..'.. .. .. ... ...:...... ..... . ...... . N..:......; .:.• I NV EL 6. 0 N 11C .... <br />[OVER PIPE END <br />':.: . ' ' .........::.:..... :''. .... '. :::: ; ..... ........... ... 5 NGVD ::11f '':.'..... '� ] <br />. ......... .......... ........... ...... .......... ......... <br />... .... . _........ .:° .. .. ... ..... .... ...... [SEE NOTE 27 <br />MIN. •' L'=• .� -•' •s i:i OR PERFORATED i5° HDPE ...... 5. FOR BAFFLE DETAILS SEE THIS SHEET <br />• • • PERFORATED i5° HOPE STEEPER 1 NV EL - 6.50 NGVD <br />00� I NV EL - 6. 50 NGVD k% <br />[SEE NOTE 27 <br />NON- SHRINK GROUT (SEE NOTE 2) " -� FILTER FABRIC cve FILTER FABRIC <br />CL <br />% BALLAST ROCK ,a�� ( " -'b <br />N ALL AROUND [TYP7 WODEN PLASTIC WODEN PLASTIC °o�� <br />o° FILTER FABRIC FILTER FABRIC BALLAST ROCK <br />BALLAST ROC <br />BOTTOM EL = [ -7 5.00 NGVD <br />1% cgk ooc� BOTTOM EL t -] 5.00 NGVD <br />3'-0" 3' -0" <br />FILTER °X" OR APPROVED EQUAL. <br />EXTENDED FILTER FABRIC <br />21-60 FRENCH DRAIN LENGTH 1' -p■ TO BOTTOM OF TRENCH. w <br />(SEE PLANS) rr <br />Q <br />ALTER CROSS-SECTION <br />NATE DETAIL TRANSVERSE SECTION DETAIL Z o� <br />LONGITUDINAL SECTION FOR SANDY SOIL CONDITION N.T.S. W 0 <br />N. T. S. > LJJ <br />FRENCH DRAIN DETAIL ZD <br />DIAMETER <br />- <br />z <br />OF PIPE <br />SEE BAFFLE DETAIL <br />TO FRENCH RAI <br />O <br />°- Z z U) <br />0) <br />�- <br />CY) Cll <br />� <br />Q <br />� <br />`i <br />m <br />C LO <br />PERMFOOT NO 241 <br />¢ <br />m <br />SEE NOTE i <br />a� <br />O <br />a <br />- _ <br />No. 4155 FOR CATCH BASINS <br />U) <br />BAFFLE DETAIL BY CONTRACTOR <br />MAX. TWO COURSES <br />* 4 BARS @ 6" <br />a <br />CD <br />W <br />X <br />� <br />H <br />o N <br />f v <br />L <br />C. <br />U- Ln <br />° ° <br />U O <br />O <br />0 <br />V <br />C W <br />W <br />> <br />Q <br />- <br />LO <br />no <br />Q <br />W <br />U <br />Q In 6 <br />TO FRENCH DRAIN <br />_ V <br />J <br />0 <br />- <br />U_ <br />- ^ O <br />X In U <br />BRACKET DETAIL FOR ELEVAT I oN <br />U W <br />_ - <br />>. <br />0 <br />z <br />LL <br />a <br />O <br />m <br />C C 1° - <br />Q <br />C <br />�? t-/ C <br />W U <br />J <br />H <br />X C <br />SEE NOTE i <br />OUTLETS PER FOOT INDEX NO 241 , ° °o <br />00 0 004 <br />Q (n <br />UJ_U_a <br />1/2" GALVANIZED LAG BOLT IN LEAD SHIELD [TYP.) <br />37 <br />WELD OR 2 -1/2" THRU BOLTS [ S. S. ]. <br />47 <br />GRATING SHALL BE OFFSET IF STRUCTURE IS USED <br />cn <br />IIIEnCU> <br />MINIMUM SIZE OF CATCH BASIN PER SO 2.6 OR LARGER <br />ONE BAFFLE [ 42" X42° 7, TWO BAFFLES [ 54" X54' ] SQUARE <br />POLLUTION RETARDANT CATCH BASING DETAIL <br />- <br />- <br />c~n In <br />Ln <br />W � � <br />J O0 <br />CD M <br />Q V <br />J <br />/ <br />U_J <br />III <br />3 H <br />M <br />00 <br />21-60 FRENCH DRAIN LENGTH 1' -p■ TO BOTTOM OF TRENCH. w <br />(SEE PLANS) rr <br />Q <br />ALTER CROSS-SECTION <br />NATE DETAIL TRANSVERSE SECTION DETAIL Z o� <br />LONGITUDINAL SECTION FOR SANDY SOIL CONDITION N.T.S. W 0 <br />N. T. S. > LJJ <br />FRENCH DRAIN DETAIL ZD <br />N. T. S. <br />NOTE: <br />FRENCH DRAIN SHOWN TO BE USED FOR <br />GARAGE AREAS ONLY <br />FRENCH DRAIN WITHOUT 2' SAND BE <br />TO BE USED FOR OTHER CONDITIONS <br />DRAINAGE NOTES: <br />i. These plans have been prepared with the best information available <br />to the Engineer. Contractor must verify all existing <br />underground utilities prior to beginning of construction. If any <br />discrepancies are encountered to the extent that a ■field revi- <br />sion° is required, Engineer must be notified immediately. <br />2. It is the responsibility of the Contractor to protect all existing <br />Improvements during construction. if any damage occurs as a result <br />of the construction activities, Contractor shall restore such <br />improvements to identical line, grade, estheticaI and structural <br />conditions as they were prior to beginning of construction. <br />3. A l l elevations refer to National Geodetic Vertical Datum [ N. G. V. D. ] , <br />1929. <br />4. Dade County Flood Cr i ter i a for this project Is 5.00 [ N. G. V. D. ) <br />5. October High Water Elevation 1 s 2.00 [ N. G. V. D. ). <br />6. All proposed elevations are to edge of pavement or driveway center <br />line. <br />7. All French Drain perforated pipe shall be i5" diameter and shall have a <br />minimum invert elevation of 2. 00 [ N. G. V. D. ) . (Unless otherwise noted). <br />8. French Drain bottom elevation shall be E-3 5.00 [ N. G. V. D. ] . <br />9. The following items shall be constructed in accordance with <br />the referenced details from the Dade County Public Works <br />Manual: <br />a. French Drain ....................... S. D. J. i <br />b. Catch Basin.. S. D. 2. 6 <br />c. Catch Bas i n Frame and Grate........ S. D. 2. 3 <br />d. 2' Valley Gutter ................... R. 14. 6 <br />e. P -6 Inlet .......................SD 3.4 <br />f. Swale Inlet ........................SO 3.1 <br />i0. Contractor must observe extreme care to prevent debris, silts <br />and fines from entering French Drain. Inlet Grates shall <br />remain covered with filter fabric during construction until <br />the system is ready to enter in operation. <br />Ii. Contractor to verify soil conditions at site. If muck is <br />encountered, contractor shall demuck area and fill to grade <br />with minimum 98% density. <br />12. All areas not paved must be sodded. <br />13. All work to be done in accordance with Miami -Dade County Public Works <br />Standard Details and Specifications. <br />14. All topographic and survey information is based on Sketches of Survey <br />prepared by Fortin, Leavy, Skyles Land Surveyors. <br />0. Pipe requirements: <br />French drain pipes shall be ADS Corrugated Polyethylene (Perforated]. <br />All other pipes shall be ADS N -12 Polyethylene Non - Perforated. [or <br />approved equal). <br />16. Contractor shall provide a Paving and Drainage "AS -BUILT PLAN" <br />certified by a Professional Registered Land Surveyor in the State <br />of Florida reflecting all the features of the Stormwater System <br />and should include, existin pavement and swale area grades, catch basin <br />rim and invert elevations, french drain length and bottom elevation, etc. <br />17. a. Drainage Trenches to be ZURN Z -882 6" or 12" Perma- Trench as per ZURN <br />FLO -DRAIN COMPANY [8137 754 -7148 or approved equal. <br />b. Trench Drains shall be capable of conveying a minimum flow of 1,709 gpm <br />at the last down stream section. <br />c. Contractor shall submit Shop Drawings and documentation for review and <br />approval prior to ordering and shall strictly follow manufacture's <br />Specifications and Installation Instructions. <br />d. Contractor to install Class E Grates Type Z- 882 -HDP, heel proof. capable <br />of supporting H -20 loading. <br />DIAMETER <br />- <br />OF PIPE <br />SEE BAFFLE DETAIL <br />TO FRENCH RAI <br />TO FRENCH DRAIN <br />°- Z z U) <br />V <br />o _ _w <br />CORRUGATED <br />BAINDEX <br />PERMFOOT NO 241 <br />PLAN <br />SEE NOTE i <br />L0 z <br />W U rnz <br />U.S. FOUNDRY FRAME 6 GRATE <br />BRICK TO GRADE <br />No. 4155 FOR CATCH BASINS <br />BAFFLE DETAIL BY CONTRACTOR <br />MAX. TWO COURSES <br />* 4 BARS @ 6" <br />SEE NOTE 2 0. C. E. W. [MIN 1 MUM) o ° °o <br />a °o <br />SEE NOTE 3 ' ° <br />° ° <br />Z C-) <br />8" PRECAST <br />CONC. STRUCTURE <br />PLATE TO BE WELDED <br />+ 4 BARS @ 12" <br />0. C. E. W. [MINI MUM) <br />no <br />ON TOP OF BAFFLE <br />revision /issue <br />TO FRENCH DRAIN <br />TO FRENCH DRAIN <br />m <br />BRACKET DETAIL FOR ELEVAT I oN <br />SEE PLANS a <br />BAFFLES FOR <br />POLLUTION <br />NOTES FOR P. R. CATCH BASIN D ° o <br />01 00 RETARDANT <br />00 <br />BASIN [ P. R. B. ) <br />11 <br />FI <br />SEE NOTE i <br />OUTLETS PER FOOT INDEX NO 241 , ° °o <br />00 0 004 <br />27 <br />1/2" GALVANIZED LAG BOLT IN LEAD SHIELD [TYP.) <br />37 <br />WELD OR 2 -1/2" THRU BOLTS [ S. S. ]. <br />47 <br />GRATING SHALL BE OFFSET IF STRUCTURE IS USED <br />AS OVERFLOW. <br />57 <br />MINIMUM SIZE OF CATCH BASIN PER SO 2.6 OR LARGER <br />ONE BAFFLE [ 42" X42° 7, TWO BAFFLES [ 54" X54' ] SQUARE <br />POLLUTION RETARDANT CATCH BASING DETAIL <br />N. T. S. <br />NOTE: <br />FRENCH DRAIN SHOWN TO BE USED FOR <br />GARAGE AREAS ONLY <br />FRENCH DRAIN WITHOUT 2' SAND BE <br />TO BE USED FOR OTHER CONDITIONS <br />DRAINAGE NOTES: <br />i. These plans have been prepared with the best information available <br />to the Engineer. Contractor must verify all existing <br />underground utilities prior to beginning of construction. If any <br />discrepancies are encountered to the extent that a ■field revi- <br />sion° is required, Engineer must be notified immediately. <br />2. It is the responsibility of the Contractor to protect all existing <br />Improvements during construction. if any damage occurs as a result <br />of the construction activities, Contractor shall restore such <br />improvements to identical line, grade, estheticaI and structural <br />conditions as they were prior to beginning of construction. <br />3. A l l elevations refer to National Geodetic Vertical Datum [ N. G. V. D. ] , <br />1929. <br />4. Dade County Flood Cr i ter i a for this project Is 5.00 [ N. G. V. D. ) <br />5. October High Water Elevation 1 s 2.00 [ N. G. V. D. ). <br />6. All proposed elevations are to edge of pavement or driveway center <br />line. <br />7. All French Drain perforated pipe shall be i5" diameter and shall have a <br />minimum invert elevation of 2. 00 [ N. G. V. D. ) . (Unless otherwise noted). <br />8. French Drain bottom elevation shall be E-3 5.00 [ N. G. V. D. ] . <br />9. The following items shall be constructed in accordance with <br />the referenced details from the Dade County Public Works <br />Manual: <br />a. French Drain ....................... S. D. J. i <br />b. Catch Basin.. S. D. 2. 6 <br />c. Catch Bas i n Frame and Grate........ S. D. 2. 3 <br />d. 2' Valley Gutter ................... R. 14. 6 <br />e. P -6 Inlet .......................SD 3.4 <br />f. Swale Inlet ........................SO 3.1 <br />i0. Contractor must observe extreme care to prevent debris, silts <br />and fines from entering French Drain. Inlet Grates shall <br />remain covered with filter fabric during construction until <br />the system is ready to enter in operation. <br />Ii. Contractor to verify soil conditions at site. If muck is <br />encountered, contractor shall demuck area and fill to grade <br />with minimum 98% density. <br />12. All areas not paved must be sodded. <br />13. All work to be done in accordance with Miami -Dade County Public Works <br />Standard Details and Specifications. <br />14. All topographic and survey information is based on Sketches of Survey <br />prepared by Fortin, Leavy, Skyles Land Surveyors. <br />0. Pipe requirements: <br />French drain pipes shall be ADS Corrugated Polyethylene (Perforated]. <br />All other pipes shall be ADS N -12 Polyethylene Non - Perforated. [or <br />approved equal). <br />16. Contractor shall provide a Paving and Drainage "AS -BUILT PLAN" <br />certified by a Professional Registered Land Surveyor in the State <br />of Florida reflecting all the features of the Stormwater System <br />and should include, existin pavement and swale area grades, catch basin <br />rim and invert elevations, french drain length and bottom elevation, etc. <br />17. a. Drainage Trenches to be ZURN Z -882 6" or 12" Perma- Trench as per ZURN <br />FLO -DRAIN COMPANY [8137 754 -7148 or approved equal. <br />b. Trench Drains shall be capable of conveying a minimum flow of 1,709 gpm <br />at the last down stream section. <br />c. Contractor shall submit Shop Drawings and documentation for review and <br />approval prior to ordering and shall strictly follow manufacture's <br />Specifications and Installation Instructions. <br />d. Contractor to install Class E Grates Type Z- 882 -HDP, heel proof. capable <br />of supporting H -20 loading. <br />STORM DRAINAGE <br />AAW'T <br />I L S <br />designed L. SERRATE <br />drawn N. SERRATE <br />checked L. SERRATE <br />approved R. VARGAS <br />prod no 14018 -01 <br />scale AS SHOWN <br />date AUG 13, 2014 <br />cad ref 14018 -15 <br />RODOLFO J. VARGAS <br />PE * 35648 <br />drawing <br />C-4 <br />Z = <br />am <br />°- Z z U) <br />o _ _w <br />rr J J <br />0 .1 Cn <br />b 0 - <br />z C-) <br />CI) 0 <br />L0 z <br />W U rnz <br />J � 0 <br />Ise U) <br />0 <br />Z ~ <br />Z C-) <br />U) r�n <br />no <br />date <br />revision /issue <br />STORM DRAINAGE <br />AAW'T <br />I L S <br />designed L. SERRATE <br />drawn N. SERRATE <br />checked L. SERRATE <br />approved R. VARGAS <br />prod no 14018 -01 <br />scale AS SHOWN <br />date AUG 13, 2014 <br />cad ref 14018 -15 <br />RODOLFO J. VARGAS <br />PE * 35648 <br />drawing <br />C-4 <br />