My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Addendum # 1 City of Sunny Isles Response-RFI Sheet
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
INVITATION TO BID 25-01-01 CITY ANNEX BUILDING CONSTRUCTION RENOVATIONS
>
Addendum # 1 City of Sunny Isles Response-RFI Sheet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 9:09:22 AM
Creation date
2/20/2025 9:06:04 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
City Annex Building Construction Renovations
Bid No. (xx-xx-xx)
25-01-01
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br />Project No. 21-1011 November 2024 088000 Glazing- <br />6 <br /> <br />F. Provide spacers inside and out, of correct size and spacing to preserve required face <br />clearances, for glass sizes larger than 50 united inches (length plus height), except where <br />gaskets or glazing tapes with continuous spacer rods are used for glazing. Provide 1/8 in. <br />minimum bite of spacers on glass and use thickness equal to sealant width, except with <br />sealant tape use thickness slightly less than final compressed thickness of tape. <br /> <br />G. Provide edge blocking to comply with requirements of referenced glazing standard, except <br />where otherwise required by glass unit manufacturer. <br /> <br />H. Provide compressible filler rods or equivalent back-up material, as recommended by <br />sealant and glass manufacturers, to prevent sealant from extruding into glass channel <br />weep systems and from adhering to joints back surface as well as to control depth of <br />sealant for optimum performance, unless otherwise indicated. <br /> <br />I. Force sealants into glazing channels to eliminate voids and to ensure complete wetting or <br />bond of sealant to glass and channel surfaces. <br /> <br />J. Tool exposed surfaces of sealants to provide a substantial wash away from glass. Install <br />pressurized tapes and gaskets to protrude slightly out of channel, so as to eliminate dirt <br />and moisture pockets. <br /> <br />K. Where wedge-shaped gaskets are driven into one side of channel to pressurize sealant or <br />gasket on opposite side, provide adequate anchorage to ensure that gasket will not walk <br />out when installation is subjected to movement. <br /> <br />1. Miter cut wedge-shaped gaskets at corners and install gaskets in manner <br />recommended by gasket manufacturer to prevent pull away at corners. <br /> <br />2. Seal corner joints and butt joints with sealant recommended by gasket <br />manufacturer. <br /> <br />L. Remove and replace glass that is broken, chipped, cracked, or damaged in any way. <br /> <br />M. Make all edge cuts “clean”. Do not nip, seam, swipe, stone, or strike edges. Do not knock- <br />off flares. Do not bump, drag, or brush the edges of lites against sash or another hard <br />object. Avoid scratching, particularly near an edge. <br /> <br />N. Manufacturer's label showing compliance with fire code requirements, strength, grade, <br />thickness, type and quality of glass shall remain on each piece of glass until it has been <br />set and inspected. <br /> <br />O. Install all glass by skilled glaziers, under the supervision of a qualified foreman. <br /> <br /> <br />P. Unacceptable defects: <br /> <br />1. Impact chips, spalls, nipped edges. <br /> <br />2. Flake chips, or shark teeth deeper than 1/8 of glass thickness. <br /> <br />3. Serration hackle deeper than 1/8 of glass thickness. <br />
The URL can be used to link to this page
Your browser does not support the video tag.