<br /> <br />THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br />Project No. 21-1011 November 2024 031000 -11 <br />F. The CONTRACTOR shall supply sufficient number of forms of each kind to permit the <br />required rate of progress to be maintained. <br />G. The design and inspection of concrete forms, falsework, and shoring shall comply with <br />applicable local, state, and Federal regulations. <br />3.2 WATERSTOPS: <br />A. Waterstop shall be embedded in the concrete across joints as indicated. Waterstop shall <br />be fully continuous for the extent of the joint. Splices necessary to provide such continuity <br />shall be accomplished in conformance to printed instructions of manufacturer of the <br />Waterstop. The CONTRACTOR shall take suitable precautions and means to support and <br />protect the Waterstop during the progress of the work and shall repair or replace at its <br />own expense any Waterstop damaged during the progress of the work. Waterstop shall <br />be stored so as to permit free circulation of air around the Waterstop material. <br />B. When any Waterstop is installed in the concrete on one side of a joint, while the other half <br />or portion of the Waterstop remains exposed to the atmosphere for more than 2 days, <br />suitable precautions shall be taken to shade and protect the exposed Waterstop from direct <br />rays of the sun during the entire exposure and until the exposed portion of the Waterstop <br />is embedded in concrete. <br />3.3 SPLICES IN PVC WATERSTOPS: <br />A. Splices in PVC Waterstop shall be performed by heat sealing the adjacent Waterstop <br />sections in accordance with the manufacturer's printed recommendations. It is essential <br />that: <br />1. The material not be damaged by heat sealing. <br />2. The splices have a tensile strength of not less than 80 percent of the unspliced <br />material tensile strength. <br />3. The continuity of the Waterstop ribs and of its tubular center axis be maintained. <br />No edge welding is allowed. <br />B. Butt joints of the ends of 2 identical Waterstop sections may be made while the material <br />is in the forms. <br />C. All joints with Waterstop involving more than 2 ends to be jointed together, and all joints <br />which involve an angle cut, alignment change, or the joining of 2 dissimilar Waterstop <br />sections shall be prefabricated (shop made fitting) prior to placement in the forms, allowing <br />not less than 24-inch-long strips of Waterstop material beyond the joint. Upon being <br />inspected and approved, such prefabricated (shop made fitting) Waterstop joint assemblies <br />shall be installed in the forms and the ends of the 24-inch strips shall be butt welded to <br />the straight run portions of Waterstop in place in the forms. <br />D. Where a center bulb Waterstop intersects and is jointed with a non-center bulb Waterstop, <br />care shall be taken to seal the end of the center bulb, using additional PVC material if <br />needed. <br />3.4 FORM DESIGN: <br />A. Forms shall be true in every respect to the required shape and size, shall conform to the <br />established alignment and grade, and shall be of sufficient strength and rigidity to maintain