Laserfiche WebLink
THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br />Project No. 21-1011 November 2024 092216-3 <br /> <br /> <br />Condition of Use Metal Thickness <br />Total wall height of 14 ft. and less with wall <br />finish both sides <br />20 gauge <br />Total wall height of 14 ft. and less with wall <br />finish one side only <br />20 gauge <br /> <br />Total wall height of 14 ft.-20 ft.-11 in. 18 gauge <br />Total wall height of 21 ft. and higher 16 gauge <br />Walls greater than 24 ft. Consult A/E <br /> <br />1. Provide punched “C”-shaped studs of sizes indicated on Drawings for all <br />conditions. If stud sizes are not indicated on Drawings, provide 4-inch size. <br />Provide unpunched channel-shape top and bottom stud runner tracks of width <br />necessary to accommodate studs. <br /> <br />2. Where track extends to structure above use Superior No. 53 Flex Track as <br />manufactured by Porter Electrical Division, H.K. porter Co., Inc. Provide same <br />gauge and finish as studs. <br /> <br />B. Bracing angles: 3/4" x 1-1/4", 22 gage galvanized. <br /> <br />C. Screw Fasteners: Type S, 3/8", 1", and 1-5/8" long. <br /> <br />D. Channels: 16 gauge galvanized cold-rolled steel, 0.0598-inch minimum thickness and 7/16- <br />inch min. wide flanges. <br /> <br />1. Carrying Channels: 1-1/2 inch deep, 475 lbs per 1000 ft. <br /> <br />2. Furring Channels: 3/4 inch deep, 300 lbs per 1000 ft. <br /> <br />E. Furring channels (hat section): ASTM C645, hat shaped, 7/8-inch depth, roll-formed from <br />25 gage electro-galvanized steel. Provide manufacturer’s clips for attachment to runner <br />channel. <br /> <br />F. Furring Accessories: <br /> <br />1. USG DWC-25 hat channels or Gold Bond Screw Furring Channel <br /> <br />2. USG Z-Furring Channels: Manufacturer’s standard zee-shaped furring members <br />with slotted or non-slotted web, 1-1/2-inch depth, fabricated from 25 gage hot- <br />dip galvanized steel sheet complying with ASTM A525, Coating Designation G60. <br /> <br />3. Resilient Channels: USG RC-1, 25 gage, 1/2" x 2 1/2" or as sized on Drawings <br /> <br />4. Patented systems, such as W.R. Grace Construction Products Thermo-Stud <br />Exterior Wall System, will also be acceptable. <br />