Laserfiche WebLink
1EX. GWTO REMAINEX.EX.EX.2-1/2"DCWEX. GWTO REMAINEX. GWTO REMAINFCOFCO222433333333233333633336273335555328EX.GWH8EX.4" SANEX.4"FD7EX.4" SAN109911 KEY NOTES: EXISTING PLUMBING FIXTURE, COLD WATER, SANITARY, GAS, FLOOR DRAINS AND CONDENSATE PIPINGTO BE REMOVED.DEMOLITION LEGEND:1.THE EXISTING DOMESTIC COLD WATER SERVICE IS EXISTING TO REMAIN (VIF).2.THE EXISTING FIXTURE SHALL BE REMOVED. CUT AND CAP ALL ASSOCIATED PIPING WITHIN THE WALL ANDOR THE CEILING SPACE (VIF).3.THE EXISTING FLOOR DRAIN SHALL BE REMOVED, THE LINE SHALL BE CAPPED AND THE HOLE SHALL BEFILLED WITH CONCRETE (VIF). MAKE THE CONCRETE PATCH SMOOTH.4.THE EXISTING GAS PIPES SHALL BE CAPPED AND ABANDONED BELOW THE SIDEWALK AND CAP AT THEUTILITY GAS METER (VIF). PATCH THE SIDEWALK AS REQUIRED TO FILL OLD GAS PIPE PENETRATION. MAKETHE CONCRETE PATCH SMOOTH.5.THE CONTRACTOR SHALL DEMOLISH ALL THE EXISTING INTERIOR GAS PIPES AND DISCARD AS REQUIRED(VIF).6.THE GREASE WASTE PIPING IS EXISTING TO REMAIN FOR FUTURE CONNECTIONS (VIF).7.EXISTING FIXTURE TO BE REMOVED. REMOVE ALL THE UNDER-GROUND PLUMBING PIPES IN THE DEMOHATCH. THE EXISTING OVERHEAD WATER PIPING TO BE CAPPED ABOVE CEILING. VERIFY EXACT LOCATIONOF EXISTING PLUMBING LINES IN FIELD PRIOR TO CONSTRUCTION.8.DEMOLISH THE EXISTING GAS WATER HEATER & WATER SOFTNER. CUT AND CAP ALL ASSOCIATED WATERPIPING WITHIN THE WALL AND OR THE CEILING SPACE (VIF). REMOVE THE HEATER FLUE AND PATCH THEROOF PENETRATION AS REQUIRED WITH A WEATHERPROOF U/L LISTED MATERIAL.9.DEMOLISH EXISTING CONDENSATE PIPING AND SUPPORTS FROM THE ROOF (VIF).10.DEMOLISH ALL THE EXISTING GAS PIPING, GAS VENTS AND SUPPORTS FROM THE ROOF (VIF). PATCH THEGAS ROOF PENETRATION AS REQUIRED WITH A WEATHERPROOF U/L LISTED MATERIAL.11.THE CONTRACTOR SHALL FIELD VERIFY EACH VENT THAT SHALL REMAIN AND PROVIDE PERMANENT CAP ONEXISTING UN-USED VTR'S, PRIOR TO COMMENCING WORK.·THE PLUMBING CONTRACTOR SHALL VISIT THE SITE AND EXAMINE THE EXISTING CONDITIONS PRIOR TO COMMENCINGWORK AND SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER IF A CONDITION EXISTS WHICH PREVENTS THEM FROMACCOMPLISHING THE WORK INDICATED AND INTENDED BY THESE DRAWINGS.·THE PLUMBING CONTRACTOR SHALL EXERCISE EXTREME CAUTION DURING DEMOLITION WORK. EXISTING STORM ANDWATER RISER ARE SHOWN SCHEMATIC FOR REFERENCE PURPOSES ONLY. CONTRACTOR SHALL VERIFY IN FIELD THELOCATION OF ALL EXISTING TO REMAIN RISERS PRIOR TO DEMOLITION.·THE PLUMBING CONTRACTOR SHALL FIELD LOCATE THE EXISTING UNDER-SLAB PIPING TO BE REMOVED. COORDINATETHE AREAS OF CONCRETE TO BE DEMOLISHED (BY PLUMBER) WITH THE G.C. & STRUCTURAL CONTRACTOR PRIOR TOCOMMENCING WORK. THE STRUCTURAL CONTRACTOR SHALL PATCH THE CONCRETE AS REQUIRED TO COMPLETE THEPROJECT.GENERAL NOTEShttp://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t s <br />CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BUILDING DEPARTMENT RELOCATION <br />TO ANNEXNOVEMBER 25, 2024BID SETwww.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 33317THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY JOHN GRAY CUMPER ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF THIS <br />DOCUMENT ARE NOT CONSIDERED SIGNED AND <br />SEALED AND THE SIGNATURE MUST BE VERIFIED <br />ON ANY ELECTRONIC COPIES.ANNEX. BUILDING PLUMBING DEMOLITION FLOOR PLANSCALE: 3/32" = 1'-0"NANNEX. BUILDING PLUMBING DEMOLITION ROOF PLANSCALE: 3/32" = 1'-0"NPLUMBING DEMO PLANPD101