Laserfiche WebLink
CLERK #2WATER HEATERROOMELECTRICALROOMLIBRARY / FILES(FLOOR TO CEILING HEIGHT)CAFEEGRESSPLANPREPDESKLIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT) <br />LIBRARY / FILES <br />(FLOOR TO PARTITION HEIGHT)EGRESSCLERK #1EGRESS037RESTROOMWOMENS038RESTROOMMALE039RESTROOMWOMENS042UNISEXRESTROOM040RESTROOMMALE041CLOSETJANITOR036CLOSETJANITOR035STORAGE034ADMINISTRATORBUSINESS CENTER028PLAN EXAMINERSR. BUILDING027INSPECTOR026INSPECTOR013INSPECTORBUILDING006ADMIN005ADMIN032SUPERVISORPERMITCALL CENTER011003BREAKROOM008INSPECTORCHIEF PLUMBING014ADMINISTRATORFLOOD PLAIN007INSPECTORCHIEF BUILDING018INSPECTORSR. MECHANICAL009INSPECTORCHIEF MECHANICAL021INSPECTORELECTRICAL016INSPECTORPLUMBING023INSPECTOR020INSPECTORSR. ELECTRICAL002MANAGERBUILDING DEPT.010INSPECTORCHIEF ELECTRICAL025PLAN EXAMINERSR. BUILDING024INSPECTOR004BUILDING OFFICIALASSISTANT017ROOMCONFERENCE019INSPECTORMECHANICAL015INSPECTORSR. PLUMBING001OR DIRECTORBUILDING OFFICIAL043WAITING AREA044LOBBY / ENTRANCE029IT ROOM033SUPERVISORBUSINESS CENTER022ROOMMEETING031COORDINATORPLAN030PLAN EXAMINERSTRUCTURE012INSPECTORSR. BUILDINGK-6710WHITBYC_SINKSCAST IRON <br />K-6710WHITBYC_SINKSCAST IRONA-37,39WAPWAPWAPWAPWAPWAPWAPB-1FAAPCMCMMDPATS-SB1E10075cd75cd15cd75cd15cdEWH-1B-27 15cd15cd15cd75cd75cd15cd75cd75cd75cdPNL APNL B15cd15cdGENANNUN.HWH-1 <br />15cd15cd15cdWPWPWPWPFACP <br />PNL C15cdTV,56"B-3B-3B-5B-5B-4B-4B-21B-748"15cd15cdB-31B-31C-1B-1B-1TV,56"CM15cdB-23,25 <br />48"48"48"48"48"75cdA-41RECIRC <br />PUMP <br />48"554TV,56"TV,56"TV,56"B-6B-6B-7B-348"15cdTV,56"TV,56"TV,56"TV,56"TV,56"TV,56"TV,56"B-2WPWPWPWPWPWPWPB-8B-9B-10B-11B-12B-13B-17B-15B-16B-19B-19B-19B-19B-19B-19B-33B-31B-3148"WP48"WP48"WPC-2C-2C-2TV,56"TV,56"B-26B-28TV,56"A-2,4,6,8A-10,12,14,16A-18,20,22,24A-26,28,30,3248"B-33B-29B-35B-30B-1944444444444444111122228333A-34,363PCV <br />PCVPCVPCVPCV <br />FSDFSDPCV24"x16" WALL PENETRATIONW/FSD CAPPED FOR FUTURE S/ADUCT FROM RTU-3.26"x16" WALL PENETRATIONW/FSD CAPPED FOR FUTURE R/ADUCT TO RTU-3.DAHU-1A-19,21B-45B-49B-51B-39B-41B-37B-38INV. PNLB-449S <br />DD <br />S <br />DD <br />B-46B-710112211ELECTRICALROOMNEW FIRE ALARM CONTROL PANELMDPATS-SBABDAHU-2NEW 720W MEDIUM-CAPACITY MINIINVERTER SERIES97Electrical Floor PlanE100ELECTRICAL FLOOR PLANSCALE: 3/16" = 1'-0"NKEYED NOTES:PROVIDE FLOOR BOX FURNITURE INFEED WITH 34" LFMC TOSYSTEM FURNITURE ELECTRICAL CONNECTION AND (2) 1" LFMCTO SYSTEM FURNITURE COMMUNICATIONS RACEWAY FOR DATACABLING. BASIS OF DESIGN: WIREMOLD MULTIPLEX MP8 DUALSERVICE PRODUCT FAMILY.INFLOOR FLUSH DUCT SYSTEM WITH (2) SEPARATE DUCTS FORPOWER AND COMMUNICATIONS CABLNG. BASIS OF DESIGN:WIREMOLD FLUSH DUCT222F-0. ELECTRICAL CONTRACTORSHALL COORDINATED WITH VENDOR TO PROVIDE ALL ADAPTORPLATES, FACEPLATES, FITTINGS, PLUGS AND/OR ANY OTHERCOMPONENTS NECESSARY FOR COMPLETE ISNTALLATION.PROVIDE 3-GANG SLAB-ON-GRADE CAST IRON FLOOR BOX WITH(1) 34" CONDUIT FOR POWER AND (2) 1" CONDUIT FOR DATA ANDA/V. CONDUIT TO BE ROUTED TO NEAREST WALL AND THENSTUBBED UP INTO ACCESSIBLE CEILING SPACE.SYSTEM FURNITURE MANUFACTURER IS RESPONSIBLE FORFURNISHING ALL DEVICES FOR POWER AND LOW VOLTAGEWITHIN EACH CUBICLE WORK STATION. ELECTRICALCONTRACTOR SHALL TERMINATE POWER AT THE DESIGNATEDSINGLE POINT ELECTRICAL CONNECTION. LOW VOLTAGECABLING AND TERMINATIONS BY OTHERS.PROVIDE (2) 3/4" CONDUIT FOR POWER AND CONTROL FROMOUTDOOR CONDENSING UNIT.EXHAUST FANS ARE TO BE CONNECTED TO LIGHTING CIRCUIT INTHE RESPECTIVE AREA.EXISTING TELECOMMUNICATIONS SERVICE ENTRANCE TO BEREUSED. PROVIDE NEW CONDUITS SLEEVES TO ADJACENTROOM AS SHOWN ON LOW VOLTAGE RISER, SHEET E-602.FLUSH DUCT SYSTEM 90 DEGREE ELBOWS WITH CONDUITADAPTERS FOR IN WALL TRANSITION AND EXTENSION CABLINGSERVING PANEL AND I.T. CLOSET.NEW 250WATT MEDIUM-CAPACITY MINI INVERTER SERIES MODEL#: EMIU-250-4-LDC-120 OR EQUAL.PROVIDE (2) SEPARATE JUNCTION BOXES FOR POWER ANDCOMMUNICATIONS INFEED TO SYSTEM FURNITURE. PROVIDE1-1/4" CONDUIT STUB-UP FOR COMMUNICATIONS CABLING.PROVIDE FIRE ALARM RELAY TO INTERRUPT POWER TO ACCESSCONTROL DOOR MAG LOCK.123GENERAL NOTES:1. SYSTEM FURNITURE MANUFACTURER IS RESPONSIBLE FORFURNISHING ALL DEVICES FOR POWER AND LOW VOLTAGEWITHIN EACH CUBICLE WORK STATION. ELECTRICALCONTRACTOR SHALL TERMINATE POWER AT THEDESIGNATED SINGLE POINT ELECTRICAL CONNECTION. LOWVOLTAGE CABLING AND TERMINATIONS BY OTHERS.2. EACH EXHAUST FAN INDICATED ON THIS DRAWING SHALL BECIRCUITED TO THE ASSOCIATED SPACE LIGHTING CIRCUITAND CONTROL. PROVIDE TOGGLE SWITCH DISCONNECT ASNEEDED FOR NEC CODE COMPLIANCE.4ELECTRICAL DEMO PLANSCALE: 1/2" = 1'-0"N1E100NOTE: MAIN SWITCHGEARLOCATED IN THE ELECTRICALROOM IS TO BE COMPLETELYDEMOLISHED.56ELECTRICAL ROOM PLANSCALE: 1/2" = 1'-0"N1E100778B-#GENERAL NOTES:TAG REPRESENTS PANEL CIRCUIT NUMBER FOR ALLRECEPTACLES IN THE ASSOCIATED SPACE. THE LETTERDESIGNATES THE ELECTRICAL PANEL THE CIRCUITS AREFED FROM AND THE NUMBER, DESIGNATES THE CIRCUITSPACE IN THE ELECTRICAL PANEL.9http://www.beai.com <br />PHONE: (305) 461-2053 <br />LICENSE No. AA26001612 <br />Miami, Florida 33168 <br />11575 Northwest 7 Avenue <br />FAX: (305) 634-0599 <br />E-mail: info@beai.com <br />BEA architects Inc. <br />© a r c h i t e c t sNOVEMBER 25, 2024CITY OF SUNNY ISLES BEACH <br />18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011BUILDING DEPARTMENT RELOCATION <br />TO ANNEX <br />THIS ITEM HAS BEEN DIGITALLY SIGNED AND <br />SEALED BY ALEX ROBINSON ON THE DATE <br />ADJACENT TO THE SEAL. PRINTED COPIES OF <br />THIS DOCUMENT ARE NOT CONSIDERED SIGNED <br />AND SEALED AND THE SIGNATURE MUST BE <br />VERIFIED ON ANY ELECTRONIC COPIES.www.hammondengineers.com499 N.W. 70thAvenue,Suite 215Plantation, Florida 333171011