My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Addendum # 1 City of Sunny Isles Response-RFI Sheet
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
Addendum # 1 City of Sunny Isles Response-RFI Sheet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2025 12:55:54 PM
Creation date
3/10/2025 12:51:21 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LED LIGHT <br />CONTINUOUS LINEAR <br />LED WALL WASH LIGHT <br />FIXTURE <br />1 <br />7'-3"14'-6"4'-10"3'-10"15'-8"29'-3" <br />132'-5" <br />5'-7"28'-3"9'-7"4'-8"13'-3"9'-6"2'-10"9'-2"7'-5"1'-9"8'-1"7'-9"8'-9"8'-0"96'-3"2 3 4 5 6 7 8 9 <br />A <br />B <br />C <br />D <br />E <br />F <br />H <br />I <br />J <br />K <br />L <br />N <br />0.90.8 <br />12'-3"11'-0" <br />G <br />5'-6"M http://www.beai.comPHONE: (305) 461-2053LICENSE No. AA26001612Miami, Florida 3316811575 Northwest 7 AvenueFAX: (305) 634-0599 E-mail: info@beai.comBEA architects Inc.© a r c h i t e c t sNOVEMBER 2024 ADRIAN PRICE FL. LICENSE #AR97981CITY OF SUNNY ISLES BEACH18050 COLLINS AVENUE, SUNNY ISLES BEACH, FLORIDA 3316021-1011 <br />BID SET BUILDING DEPARTMENT RELOCATIONTO ANNEXROOF PLAN <br />P.L.A.P. <br />3/16" = 1'-0" <br />ROOF PLAN <br />A-104 <br />N <br />3/16"=1'-0"1 <br />EL +15'-0" <br />T.O. ROOF <br />EL +18'-4" <br />T.O. ROOF <br />AREA A <br />AREA D <br />EL +16'-0" <br />T.O. PARAPET <br />EL +16'-0" <br />T.O. PARAPET <br />EL +13'-0" <br />T.O. PARAPET <br />EXISTING TO REMAIN <br />NEW CANOPY <br />NEW ROOFING SYSTEM <br />EL +8'-8" <br />B.O. CANOPY <br />NEW HVAC RTU <br />SEE MECHANICAL <br />FOR DETAILS <br />NEW HVAC RTU <br />SEE MECHANICAL <br />FOR DETAILS <br />NEW HVAC RTU <br />SEE MECHANICAL <br />FOR DETAILS <br />3 <br />A-407 <br />CONTINUOUS LINEAR LED <br />WALL WASH LIGHT FIXTURE <br />SHADING LEGEND <br />A-508 <br />1 <br />A-508 <br />2 <br />A-508 <br />6 <br />EL +8'-8" <br />B.O. CANOPY <br />EL +8'-8" <br />B.O. CANOPY <br />EL +8'-8" <br />B.O. CANOPY <br />EL +8'-8" <br />B.O. CANOPY <br />A-508 <br />6 <br />A-508 <br />5 <br />A-508 <br />3 <br />A-508 <br />4 <br />EL +8'-8" <br />B.O. CANOPY <br />EL +23'-3" <br />T.O. STRUCTURE <br />EL +13'-0" <br />T.O. ROOF <br />AREA B <br />EL +15'-0" <br />T.O. ROOF <br />AREA C <br />EL +19'-4" <br />T.O. PARAPET <br />EL +27'-0" <br />T.O. PARAPET <br />A-407 <br />4 <br />A-508 <br />8 <br />SHADING LEGEND <br />NEW TPO ROOF <br />NOA: 19-1023.05 <br />NEW TPO ROOF <br />NOA: 19-1023.05 <br />NEW TPO ROOF <br />NOA: 19-1023.05 <br />NEW TPO ROOF <br />NOA: 19-1023.05 <br />A-508 <br />7 <br />A-508 <br />7 <br />A-508 <br />7 <br />GENERAL NOTES: <br />EL +16'-0" <br />T.O. PARAPET <br />A-502 <br />3 <br />EXISTING ROOF DRAINS TO REMAIN <br />EXISTING ROOF DRAINS TO REMAIN <br />NEW RWL <br />NEW RWL <br />NEW RWL <br />NEW RWL <br />1.SEE SHEET A-508 DETAIL 9 FOR <br />ROOFING PATCHING DETAILS. <br />2.G.C. TO SUBMIT ROOFING CORE <br />SAMPLES FOR EXISTING ROOFING <br />ASSEMBLY. <br />3.G.C. SHALL FIELD VERIFY ALL EXISTING <br />STRUCTURE INCLUDING DIMENSIONS, <br />LOCATION, & MATERIAL COMPOSITION <br />4.G.C. SHALL IDENTIFY AND FIELD <br />VERIFY EXISTING ROOF DOWN PIPE <br />ROUTES FROM ROOF TO EXISTING <br />FLOOR SLAB AND REPORT ANY <br />DEVIATIONS FROM PLANS. <br />5.PROVIDE CONCRETE SPLASH BLOCK <br />AT DISCHARGE END OF RAIN WATER <br />LEADER. COLOR TO MATCH RAIN <br />WATER LEADER. <br />6.FIELD VERIFY ALL DIMENSIONS AND <br />ELEVATION OF ROOF STRUCTURE <br />PRIOR TO PREPARATION OF ROOF <br />SHOP DRAWINGS. <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />2 <br />2 2 <br />2 <br />3 <br />3 <br />33 <br />3 <br />3 <br />1' <br />3 <br />333 <br />ROOF UPLIFTING PLAN <br />N.T.S.2 <br />ROOFING UPLIFTS <br />THE ROOFING UPLIFTS LOADS PROVIDED ARE <br />BASED ON ASCE 7-16. THE LOADS ARE <br />SERVICE/ASD PRESSURES. <br />ZONE 2 <br />ZONE 3 <br />ZONE 1' <br />ZONE 1 <br />141 PSF <br />103.0 PSF <br />78.3 PSF <br />45.0 PSF <br />ROOF AREA <br />4.5(IN/HR) <br />ROOF GUTTER CALCULATIONS <br />322.70 SF <br />RAINFALL INTENSITY <br /> PER HOUR <br />37.22 GPM <br />TOTAL FLOW <br />RATE <br />(DETERMINED IN ACCORDANCE WITH TABLE 1106.6 OF THE INTERNATIONAL PLUMBING CODE) <br />2 -1/2" x 2 -1/2" <br />VERTICAL LEADER <br />SIZING (INCHES) <br />1 <br />619.14 SF 71.41 GPM2 <br />310.40 SF 35.80 GPM3 <br />131.77 SF 15.20 GPM4 <br />2" x 4"4.5(IN/HR) <br />4.5(IN/HR) <br />4.5(IN/HR) <br />2 -1/2" x 2 -1/2" <br />2" x 4" <br />AREA 1 <br />AREA <br />AREA 2 <br />AREA 3 AREA 4 <br />NEW RWL <br />ADDENDUM 11 <br />1 <br />1 <br />1 <br />02-14-25 <br />1 <br />1 <br />TPO ROOFING SPECIFICATIONS <br />BRAND AND MODEL THICKNESS COLOR WARRANTY <br />COVERAGE INSULATION TYPE ATTACHMENT METHOD REMARK <br />GAF EVERGAURD FREEDOM <br />TPO HW SINGLE PLY ROOFING <br />SYSTEM OVER STEEL DECKS <br />80 MIL WHITE 20 YEARS POLYISO RIGID <br />INSULATION SELF ADHERED OR SIMILAR APPROVED <br />1
The URL can be used to link to this page
Your browser does not support the video tag.