My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2025-3808
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2025
>
Reso 2025-3808
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2025 10:11:48 AM
Creation date
4/9/2025 4:14:27 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2025-3808
Date (mm/dd/yyyy)
03/20/2025
Description
City Mgr. to negotiate an Agreement w/ Garland/DBS, Inc. to replace Roof at Government Center.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Sunny Isles <br />P2, Lower East Roof Sections <br />O. National Roofing Contractors Association (NRCA): Roofing and Waterproofing Manual. <br />P. Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA) - <br />Architectural Sheet Metal Manual. <br />Q. Underwriters Laboratories, Inc. (UL): Fire Hazard Classifications. <br />R. Intertek/Warnock Hersey (WH): Fire Hazard Classifications. <br />S. ANSI-SPRI ES -1 Wind Design Standard for Edge Systems used with Low Slope Roofing <br />Systems. <br />T. ASCE 7-22, Minimum Design Loads for Buildings and Other Structures <br />U. UL - Fire Resistance Directory. <br />V. FM Approvals - Roof Coverings and/or RoofNav assembly database. <br />W. FBC - Florida Building Code. <br />X. Miami -Dade Building Code Compliance - N.O.A. (Notice of Acceptance). <br />1.3 DESIGN / PERFORMANCE REQUIREMENTS <br />A. Perform work in accordance with all federal, state and local codes. <br />B. Exterior Fire Test Exposure: Roof system shall achieve a UL, FM or WH Class rating for roof <br />slopes indicated on the Drawings as follows: <br />1. Factory Mutual Class A Rating. <br />2. Underwriters Laboratory Class A Rating. <br />3. Intertek/Warnock Hersey Class A Rating. <br />C. Design Requirements: <br />1. Uniform Wind Uplift Load Capacity <br />a. Installed roof system shall withstand negative (uplift) design wind loading <br />pressures complying with the following criteria. <br />1) Design Code: ASCE 7-22, Method 2 for Components and Cladding. <br />2) Refer to wind calculations (attached) <br />2. Live Load: Not to exceed original building design. <br />3. Dead Load: <br />a. Installation of new roofing materials shall not exceed the dead load capacity of <br />the existing roof structure. <br />D. Roof system shall have been tested in compliance with the following codes and test <br />requirements: <br />Miami -Dade County: NOA No. 24-1114.04 page 32 <br />1.4 SUBMITTALS <br />A. Submit under provisions herein <br />B. Product Data: Manufacturer's data sheets on each product to be used, including: <br />1. Preparation instructions and recommendations. <br />2. Storage and handling requirements and recommendations. <br />3. Installation instructions. <br />C. Shop Drawings: Submit shop drawings including installation details of roofing, flashing, <br />07 52 00 -3 <br />
The URL can be used to link to this page