Laserfiche WebLink
THE GARLAND COMPANY, INC. Fascia <br />HIGH-PERFORMANCE BUILDING ENVELOPE SOLUTIONS <br />f96 3800 EAST 91ST. STREET • CLEVELAND, OHIO 44105-2197 Date 1/24/2025 <br />p. (216) 641-7500 • f. (216) 641-0633 • 800-321-9336 • w w.garlandco.com Sales Rep Wrk Humbaugh <br />Project Name City of Sunny Isles Beach !city Sunny Isles beach <br />Roof Sections .Lower East State FL <br />ANSVSPRI ES -1 FASCIA PRELIMINARY DESIGN <br />Project Data <br />Design Wind Speed: <br />186 <br />mph <br />Roof Eave Height: <br />25.00 <br />feet <br />Tallest Parapet: <br />0.00 <br />feet <br />Metal Edge Eave Height: <br />n <br />25.00 <br />feet <br />Exposure Category: <br />D <br />Importance Classification: <br />III <br />Design Wind Pressure ASCE 7-22 ASD <br />Basic Velocity Pressure: 51.09 psf <br />Horizontal Design Pressure: 92.48 psf <br />ES -1 Fascia Load <br />Vertical Face Dimension: 7.25 inches <br />Fascia Design Load: 154.44 psf <br />ES -1 Tested Fascia System <br />Product Designation: MEA-RMF-Fascia725-Z24 <br />System Description: R -Mer Force Fascia 7.25" x 24 GA w/ RMEBF-700 Base Frame <br />Maximum Tested Load: 320 psf <br />Max. Vertical Face Dim.: 7.25 inches <br />