Laserfiche WebLink
THE GARLAND COMPANY, INC. Fascia <br />HIGH-PERFORMANCE BUILDING ENVELOPE SOLUTIONS <br />eBfi 3800 EAST 91ST. STREET - CLEVELAND, OHIO 44105-2197 Date 11/11/2024 <br />p. (216) 641-7500 • f. (216) 641-0633 • 800-321-9336 • w w.garlandco.com Sales Rep Mark Humbaugh <br />roject Name Sunny Isles Gov't Center Upper Roof City Sunny Isles Beach <br />oofSections ;UpperState AFL <br />ANSVSPRI ES -1 FASCIA PRELIMINARY DESIGN <br />Project Data <br />Design Wind Speed: <br />195 <br />mph <br />Roof Eave Height: <br />65.00 <br />feet <br />Tallest Parapet: <br />3.17 <br />u <br />feet <br />Metal Edge Eave Height: <br />68.17 <br />feet <br />Exposure Category: <br />C <br />Importance Classification: <br />IV <br />Design Wind Pressure ASCE 7-22 ASD <br />Basic Velocity Pressure: 57.52 psf <br />Horizontal Design Pressure: 135.18 psf <br />ES -1 Fascia Load <br />Vertical Face Dimension: 7.25 inches <br />Fascia Design Load: 225.75 psf <br />ES -1 Tested Fascia System <br />Product Designation: MEA-RMF-Fascia725-A40 <br />System Description: R -Mer Force Fascia 7.25" x 0.040" Aluminum w/ RMEBF-700 Base Frame <br />Maximum Tested Load: 470 psf <br />Max. Vertical Face Dim.: 7.25 inches <br />