My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CES Consultants, Inc. Bid Document (23)
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
RFQ
>
(26-07-01) Continuing Professional Architectural & Engineering Consulting Services (CCNA)
>
PROPOSALS
>
CES Consultants, Inc
>
CES Consultants, Inc. Bid Document (23)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2026 12:40:45 PM
Creation date
8/31/2026 12:37:45 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
251
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RFQ # 26-07-01 | CITY OF SUNNY ISLES BEACH | CONTINUING PROFESSIONAL ARCHITECTURAL AND ENGINEERING CONSULTING SERVICES (CCNA)132 <br />CES CONSULTANTS, INC. <br />•City of Fort Lauderdale Design Criteria Packages for Fire Stations 13 and 88; Fort Lauderdale, FL:Responsible for the development of two design criteria packages for Fire Station 13 and Fire Station 88projects, which are intended to be completed under design-build contracts. <br />•Town of Davie Police Department Emergency Generator; Davie, FL: Project Manager for the installation of a new exterior emergency generator at the Town’s Police Headquarters. Due to failure of thegenerator during Hurricane Irma, the existing 750kw interior generator will be replaced by a new 750kwexterior generator. The existing generator is fueled by an existing 8,000-gallon underground storagetank and day tank. It will provide full back-up power for the Police Headquarters building and adjacentFire Department Station 65 building. <br />•Inc. Village of Westhampton Beach Main Street Improvements Design; Westhampton Beach, NY: LeadElectrical Engineer for the removal of overhead utility wires and design of lighting replacement for thereconstruction of approximately 2,700 feet of roadway. Coordinated closely with PSEG Long Island onthe location of approximately 7,200 feet of electrical conduit and 37 pull boxes and transformer concrete pads for primary service within Main Street. Lighting replacements includes decorate street lightingproviding appropriate pedestrian and roadway illumination. Project received a 2020 ACEC PlatinumEngineering Award. <br />•Town of Hempstead New Office Building; Merrick, NY: Lead Electrical Engineer for a needs assessmentstudy for the development of a new office building for the Town’s Department of Sanitation. Developedthree new office building designs for Town consideration, along with site scenarios. <br />•Hudson River Park Trust (HRPT) Sports Field Lighting Upgrades; New York, NY: As part of an on-call contract with the HRPT, providing design and construction administration support services forreplacement of the sports field lighting at Hudson River Park Trust’s Pier 40. H2M’s design solutionincludes the removal of select light poles while others will remain in place. A cluster of new fixtures wasdesigned for the poles that are remaining. Although the total number of fixtures per pole was increased,the overall weight of the new cluster was verified and will not exceed the allowable gravity load of theexisting light poles. At the locations where light poles will be removed, the exposed holes will be patched per the structural engineer’s design details. <br />•New York State Office for People With Developmental Disabilities (OPWDD) Mt Ivy Standby GeneratorDesign; Pomona, NY: Supervised the development of design drawings to replace an existing dieselgenerator with a propane-fueled generator. The design included a new above ground propane tank, new automatic transfer switch and generator disconnect. <br />•New York State OPWDD Stoneham Standby Generator Design; New City, NY: Supervised thedevelopment of design drawings to replace an existing diesel generator with a propane-fueled generator. The design included a new above ground propane tank, new automatic transfer switch and generatordisconnect. <br />•United States Postal Services (USPS) Fire Alarm Investigation; Montvale, NJ: QA/QC Reviewer for areport issued to the USPS based on a site survey of the existing fire alarm system at the main post officein Montvale, NJ. The team evaluated the fire alarm control panel (FACP), fire alarm system devices,system wiring methods, power supplies, remote reporting capabilities, and any possible obstructions.The report included review of inspection reports, developed a scope of work for upgrades and repairs,and provided a preliminary cost estimate for the proposed work. <br />Education <br />B.S., Electrical Engineering; <br />Polytechnic University <br />Licenses/ <br />Certifications <br />Professional Engineer: NY, NJ, CT, FL, VA <br />Project Management Training Program, H2M <br />H2M Mentoring Program Graduate, Mentee <br />Mr. Kim is an electrical engineer with more than 15 years of experience. His responsibilities include the <br />design of power distribution, new electrical services and service upgrades, emergency generators and <br />systems, electric vehicle (EV) charging systems, interior and exterior lighting, fire alarm systems, CCTV <br />and access control systems, and security alarm systems. He is also involved in shop drawing review and <br />construction phase services. Mr. Kim is proficient in Revit MEP and has developed the electrical portion <br />of the building information models (BIM) for key projects. <br />Selected project experience <br />Vice President, Department Manager - Electrical Engineering <br />Anthony W. Kim P.E.
The URL can be used to link to this page
Your browser does not support the video tag.