Outdoor lighting standards. <br />Lighting shall be designed and placed to Illuminate the ground, a vehicular use area, <br />a building, a street, or a sign. All lighting shall be concentrated on the ground, <br />building, street, or sign it Is Intended to illuminate. Lighting which is designed to <br />Illuminate the building roof area, except for safety reasons, shall be prohibited. <br />Minimum illumination. All multifamily, shopping centers and office buildings shall <br />Illuminate parking lots and pedestrian areas to a minimum maintained average of <br />1.0 footcandle and a maximum to minimum ratio of 12 to 1, with no area below the <br />Illumination of 0.5 footcendle. <br />Maximum illumination. All lighting for parking areas, buildings and signs shall be <br />located, screened, or shielded so that adjacent property, structures, and <br />rights -of -way are not directly Illuminated. All lighting for parking areas, buildings and <br />signs shall either be shaded or screened in a manner that will limit spillover of <br />lighting onto adjacent property and public rights -of -way. Spillover shall not exceed <br />0.5 footcandles measured vertically along the property line at the perimeter of the <br />property. <br />Lighting height standards. All private outdoor lighting shall be designed, located and <br />mounted at heights no greater than: <br />(1) <br />Twelve feet above grade for non -cutoff type luminaries, and <br />(2) <br />Thirty feet above grade for cutoff type luminaries. <br />i COLLINS AVENUE \,,V GARAGE PLAN <br />0 15' 30' 60' <br />Estates at Acqualina <br />Sunny Isles Beach, Florida <br />Owner: <br />GSF Acquisition, LLC. <br />A Delaware Limited Liability Company <br />Development Office: <br />17780 Collins Avenue Sunny Isles, FL <br />33160 Telephone 305933 -6301 <br />Architect: <br />Cohen Freedman Endnosa & Associates <br />8085 NW 155 Street, Miami Lakes, FL <br />33016 305.826.3999 <br />I Consultants: <br />Planners and Landscape Architect: <br />® sueesurmaaanrwtenatw <br />� wmusoecuenas>\mnm uv, <br />o»�sw <br />. <br />—A—n.7 . mawoexx . mvroo®x <br />Civil Engineer: <br />THOMAS CHECCA, P. E. <br />Environmental Consultant <br />11568 NW 73rd Manor, Parkland, FL 33076 <br />Once: 954 - 344-6664 <br />Rev: <br />Date: <br />Description: <br />By: <br />1 <br />014.08.2 <br />Response to City Comments <br />SP,LF,P <br />2 <br />014.08.2 <br />Response to City Comment. <br />SP,LF,P <br />3 <br />015.03. <br />Owner Changes <br />is <br />4 <br />015.03.2 <br />Response to City Comments <br />is <br />5 <br />0%.04.0 <br />Responeeto City Comment. <br />JS <br />Sheet Title: <br />Date: 2014.08.14 Project #:113158 <br />Drawn By: ,Jb Scale: AS SHOWN <br />Approved By: <br />Sheet Number. <br />A2.0 <br />