Laserfiche WebLink
MINIMUM CITY LANDSCAPE REQUIREMENTS <br />§ 265 -68. Minimum landscape requirements for all zoning districts.permanent link to thiis piece of conteml <br />A.Tree specifications <br />(1)Required trees shall be of a species, which normally grow to a minimum height of 25) feet and have at <br />mature crown spread of not less than 20 feet with trunks, which can be maintained, witth over six feet of <br />clear wood. Emphasis is given to the use of native species. <br />(2)AII required treesshall have a minimum caliper or diameter at breast height (D.B.H) of three inches and <br />be a minimum of 12 feet In height at time of planting. A list of approved required trees is available from <br />the Director of the Zoning, Planning and Building Department. <br />(3)Required palms shall be a minimum of 14 feet in height and six feel: of gray wood. <br />(4)No more than 40% of all required gray wood trees shall be of a pain species, <br />(5)Three palm trees shall be clustered to equal one required tree. The three palm trees; in the cluster sh all <br />be of differing heights, with a minimum three -foot stagger between adjacent palms, buL, in no case <br />smaller than 14 feet in height. Roystonea sp. (Royal Palm) and Phoenix sp. (Date Palrn) may have <br />matching heights. <br />(6)It is prohibited to paint the trunks of trees or palms <br />B.Other plant material specifications. <br />(1)Shrubs and hedges: Shall be of a self- supporting, woody, evergreen species and sh all be a minimurin <br />of two feet in height at time of planting. Hedges shall be planted and maintained so as tto form a <br />continuous, solid visual screen, of not less than three feet in height, within one year of Iplanting. Spacing[ <br />of plants shall be no more than 24 inches on center. Double staggered rows may be required in some <br />areas. <br />(2)Ground covers: May be used in lieu of grass. Ground covers shall present a finishedl appearance andd <br />reasonably complete coverage at time of planting. <br />(3)Lawn grass: Shall be St. Augustine'Floratam' solic sod, or other lawn type, as approved by the <br />Director, reasonably free of insects and noxious weedls. <br />(4)Quality: Plant material shall compy with required inspections, grading standards andl plant regulations <br />as set forth by the Florida Department of Agriculture's "Grades and Standards of Nursery Plants, Part I", <br />latest revisions, end "Grades and Standards for Nursery Plants, Part II for Palms and Trees ", or with <br />superseding standards called for in tlese specifications. Plants shall conform to Florida[ No. 1 or better <br />regarding: <br />(a)Shape and form. <br />(b)Health and vitality. <br />(c)Condifion of foliage. <br />(d)Root system. <br />(e)Free from pest and mechanical damaged. <br />(OHeavily brancied and with dense foliage. <br />(5)Mulch: All exposed soil areas In planting beds, including hedgerows, shall be ke pt weed free, anctl <br />mulched to a minimum three -inch depth (excluding seasonal color beds). Mulch should[ be replenished, as <br />needed, to meet this requirement. The use of shredded and composted Melaleuca, grade B mulch Is <br />encouraged. <br />(6)Vines: Shall be not less than 24 inches in heiglt at time of planting and may be cased in conjunction <br />with fences or walls Where required, support vines with a trellis or other suitable support system that <br />allows the vines to crow to the top of the fences or walls. <br />C.Installation. <br />(1)Planting methods. All plant material shall be installed following accepted planting procedures as <br />defined by the American Association of Nurserymen and The Florida Nurserymen and Growers <br />Association. <br />(2)Curbing. Landscaped areas, walls, structures, and walks shall require protections from the <br />encroachment or overhang of vehicles. A continuous concrete curbing not less than six; inches in height:, <br />shall be installed to prevent such encroachment. <br />(3)Existing plant credit. In instances where healthy plant material exists on site (particularly native o,r <br />xeriscape species), the Director or designee may adjust the requirements of this article! to allow credit fo)r <br />such plant material if, in his opinion, such an adjustment is in keeping with and will preserve the intent otf <br />this article. <br />(4)Permit requirements. A landscape pemit will be required prior to installation. <br />D.Irrigation. All newly landscaped areas shall be provided with a fully automatic underground irrigation system <br />that provides 100 percent coverage to all landscaped areas, except on single- family dwelling aind duplexes. Theo <br />irrigation system should be designed to provide only the required water to sustain viable plant material. The use of <br />a porous, pipe subsurface irrigation system that requires lowwater volume and pressure is encouraged when <br />adjacent to vehicular roadway areas. <br />(1)The operation of an irrigation system during periods of heavy rainfall is prohibited and sthall conform to <br />standards and regulations as established by the South Florida Water Management District. Irrigation controllers <br />shall be switched to manual operation during periods of increased rainfall. Use of min gauge sensors is required. <br />(2)For purposes of water conservation and good horticultural practice, sprinkler heads irrig ating lawns or of her <br />high water demand landscape areas shall be circuited so that they are on a separate zone and] schedules from <br />those irrigating trees, shrubbery or other reduced water requirement areas. <br />(3)Landscape irrigation systems shall be designed so that, to the greatest extent practical, water being app lied <br />to nonpervious areas is eliminated. <br />(4)Use of nonpotable water for use in the irrigation of lawn and plant material is required when determined tto be <br />available. <br />(5)Existing developed properties, which receive three or more code violations in a 12- montth period for <br />landscaping which in the opinion of the City are attributable, wholly or partially, to lack of proper watering shall be <br />required to Install an irrigation system. <br />(Ord. No. 2011 -361, § 1, 3 -17 -2011) <br />GROUNDCOVER <br />SEE PLANTING PLAN <br />3" MULCH BED SEE SPECS <br />12' DIAMETER ROOF DRAIN <br />SEE PLAN FOR EDGE CONDITION <br />SOIL SEPARATOR DRAINAGE <br />MATERIAL 3/4' THICK <br />LIGHTWEIGHT SPECIFIED SOIL MIX <br />4" RIGID PVC DRAIN PIPE <br />REDUCER <br />4" PERFORATED DRAIN PIPE <br />WITH FILTER SOCK <br />12' DIAMETER ROOF DRAIN <br />LOW SILHOUETTE DOME (TYP.) <br />STRUCTURAL SLAB <br />SEE STRUCTURAL & ARCH. <br />DRAWINGS. <br />DRAIN PENETRATION IN <br />STRUCTURAL SLAB SEE PLANS <br />FOR LOCATION <br />WATER PROOF BARRIER SEE <br />ARCH. DRAWINGS <br />o..m <br />/ L PARKING GARAGE BELOW <br />PLANTER ON STRUCTURE <br />SECTION NTS <br />N PIPE SEE <br />N PLAN FOR <br />CONDITION FOR DETAIL <br />LOPE \ <br />Estates at Acqualina <br />Sunny Isles, Florida <br />Owner: <br />GSF Acquisition, LLC. <br />A Delaware Limited Liability Company <br />D— bitntent Office <br />17780 Collins Avenue Sunny Isles, FL <br />33160 Telephone 305 -933 -8301 <br />Consultants: <br />Architect: <br />■architects <br />Cohen Freedman Encinitas & Associates <br />8085 NW 155 Street, Miami Lakes, FL <br />33016 305.826.3999 <br />Planners and Landscape Architect: <br />® eus ernxun . ssoi ,m <br />roart.ucenuennraassv,t 0 <br />j w 0 . twroaue . umnxossion , awa,ecoanon <br />Civil Engineer: <br />THOMAS CHECCA, P. E. <br />Environmental Consultant <br />11568 NW 73rd Manor, Parkland, FL 33076 <br />Once: 954- 344 -6664 <br />Rev: <br />Date: <br />Description: <br />By: <br />1 <br />2014,08.27 <br />Response to City Comments <br />MG <br />2 <br />2014.08.2E <br />Response to Final City Comments <br />MG <br />3 <br />016.03. <br />Site Plan Revisl.. <br />MG <br />4 <br />015.03. <br />Response to Initial Comments for <br />Site Plan Resubmiltal <br />1,16 <br />Sheet Title: <br />LANDSCAPE NOTES <br />AND PLANT LIST <br />Date: 2014,08.14 Project #: 113158 <br />Drawn By: MGG Scale: AS SHOWN <br />Approved By: <br />c EOSA,Ix <br />Sheet Number: <br />L -3.04 <br />