My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2015-2402
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2015
>
Reso 2015-2402
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2015 3:07:43 PM
Creation date
6/2/2015 3:07:31 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2015-2402
Date (mm/dd/yyyy)
04/16/2015
Description
3rd Amd to Agmt w/Keith & Schnars FPL Overhead to Underground Conversion Proj
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
54
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> • <br /> used with test hole reports in verifying location of existing utilities. Services assume 25 test holes <br /> within the limits described. <br /> NOTE: Additional easements, if required by LV utilities, are not included in the above estimated <br /> services. <br /> Engineering Services: <br /> Subtask E.19—Input Existing Utilities: <br /> The intent of this task is to locate existing features with a reasonable degree of accuracy so that <br /> proposed improvements can be designed to avoid conflict. Using test-hole information, in <br /> combination with plans, as-builts, and mark-ups from the individual utility providers, CONSULTANT <br /> shall input horizontal and vertical information into base-file for use in design plans. Once complete <br /> (existing information compiled and input) the base-file will be re-circulated to utility providers to <br /> ensure existing utilities are properly represented. Minor corrections and details are expected. <br /> Subtask E.20—Utility Test-Holes <br /> To ensure the accuracy of existing conditions, specific utilities will be physically located and <br /> identified with exact vertical and horizontal location designated. Test-hole locations shall correlate <br /> with critical crossings as determined by CONSULTANT. Because the nature of determining <br /> locations is dependent upon proposed design, the number of test-holes required is unknown. For <br /> purposes of establishing a unit price per test-hole, CONSULTANT assumes up to 25 test-holes <br /> may be required. The test holes are priced at$275 each. <br /> Subtask E.21 — Prepare Underground Plans (Off-Collins 185th to 191st): <br /> Utilizing completed base-file, CONSULTANT shall prepare plans for the components necessary for <br /> undergrounding of utilities. Requirements of each utility will be identified and incorporated into <br /> proposed design. CONSULTANT shall coordinate underground conduit needs, locations, structure <br /> sizes, and above-ground equipment. In addition, CONSULTANT shall identify proposed <br /> easements required to accommodate additional above-grade conditions. CONSULTANT assumes <br /> all underground features to be located within the existing right-of-way. <br /> Subtask E.22—Coordinate FPL Plan Revisions(Off-Collins 175th to 178th) <br /> Using the updated plans to be provided by FPL, CONSULTANT shall modify their plans to reflect <br /> the FPL revisions. CONSULTANT modifications shall include relocation and/or addition of modified <br /> easements, equipment, conduits (size, location, & routing) and impacts to ductbank. Where <br /> necessary, CONSULTANT shall perform field reconnaissance for the purpose of siting easements <br /> within private parcels. CONSULTANT shall coordinate request for information and clarifications <br /> Professional Services Agreement <br /> Project Name: Utility Undergrounding Consulting—Phase III <br /> Project Location:Sunny Isles Beach,FL <br /> K&S Project 18073—Amendment No.4 <br /> January 27,2015 Revised March 31.2015 Page 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.