LU /5 if5r <br /> •a„ ar.�_ " " P.O. Box 451262 907 <br /> ' 5#= m x Contractor ID: <br /> �' `' Sunrise Fl. 33345-1262 <br /> �r 'y1 _- _,,,- . Work Order 15442 <br /> ` ' — Phone: (954)553-3675 Date 01/30!2015 <br /> r � -- ,11*` <r o (954)572-0806 <br /> Fax: <br /> PETROLEUM TESTING o SERVICES <br /> A.T.G. Monitoring Certification Report <br /> Contractor Information Site Information <br /> CITY OF SUNNY ISLES. GOV. CITY OF SUNNY ISLES. <br /> 18070 COLLINS AVE 18070 COLLINS AVE <br /> Sunny Isles Fl 33160 SUNNY ISLES BEAC FL 33160 <br /> ID 907 Name Compliance Site Contact Victor M. <br /> Phone (786) 351-5661 Fax (305)742-1676 Phone 786 35. 661 Fax <br /> n <br /> 1-5 <br /> (305)792-1676 <br /> FAC 62-751 LEAK DETECTION SYSTEM TEST <br /> A.T.G-System's monitoring Make,Model, Serial# IVeeder Root TLS 300-C SER#E09167299505001 <br /> Electronic in tank gauging: YES TYPe MAG TANK PROBES f 1 <br /> Electronic Annular Sensor. YES Type: BELL/STRAIGHT'/STEEL <br /> S.T.P.Sump Sensor NIA Type: IA.S"T: Quantity NIA <br /> Mechanical tine Leak Detectors? N/A Testing? ISUCTION <br /> Electronic In Line Leak Detection? NIA Testing? IN/A System type?IAS.T. <br /> Dispenser Pan Sensors: NIA Type: IN/A Other Sensors 'TRANS SUMPS. <br /> Alarm History: C addrt sensors lout. TRANS.SUMPS AND DAY TANK. <br /> In Tank set-up overfill limit set at 95% YES In Tank set-up High Product set at 98%: 90% <br /> NFPA 30 Annual Impact Valve Test <br /> Are all despenser impacts valves fully opeartional IYES <br /> Are the impact valves mounted properly? [YES <br /> Leakage present? (NONE <br /> T-1 S:T:DIESEL TANK PROBE 117 DAY TANK OVERFILL ALARM <br /> L-1 !EAST PIPING SUMP �" FT DAY TANK/SENSOR ALARMS <br /> L•2 (CENTER PIPING SUMP R-3 REMOTE ANNUNCIATOR. • <br /> L=3 ITANK INTERSTITIAL SENSOR f I FILL PIPING CABINET BOX/1068444 4 <br /> L,4 IWEST PIPING SUMP fl I <br /> L DAY TANK CONTAINMENT SENSOR r"" I <br /> Testing &Servicing Results: <br /> is the audible alann functioning? YES Are all visual alarm lighting fully operational YES - <br /> Were all sensors visually inpsected,funtionally tested,and confirmed operational YES <br /> Were any of the monitoring system or accessories replaced to complete certification NO <br /> COMMENTS - - ._ —-- . <br /> System monitors Diesel AST gauging,Annular space,piping sumps, and generator system.System equipped with <br /> a remote Veeder Roor Annunciator. System is fully functional and operating properly. <br /> Florida RQ #0066477 EQ-452 Certification#727830 <br /> Certified Technician: Marty Sweet Signature: -1, <br />