My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment A - 2015-3-13_Samson Park Technical Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(15-05-01) Samson Oceanfront Park Improvements
>
Attachment A - 2015-3-13_Samson Park Technical Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2015 10:00:19 AM
Creation date
11/12/2015 9:46:40 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAMSON OCEANFRONT PARK <br />CITY OF SUNNY ISLES <br />TECHNICAL SPECIFICATIONS <br />UNIT MASONRY 040500-13 <br />C. Split faced concrete masonry unit lintels shall be formed with a "Form Block" lintel block, filled <br />with 5,000 psi concrete and reinforced as shown on Structural Drawings. For 8" thickness walls, <br />spans up to 8 '-0" may be supported with a 16" deep lintel consisting of a lintel block with a form <br />block above, reinforced with one #7 bar top and bottom and full height 5,000 psi concrete fill. <br /> <br />3.11 <br /> <br />FLASHING/WEEP HOLES: <br />A. General: Install embedded flashing and weep holes in masonry at finish floor, shelf angles, lintels, <br />ledges, other obstructions to the downward flow of water in the wall, and where indicated on <br />Drawings. <br /> <br />B. Prepare masonry surfaces so that they are smooth and free from projections that could puncture <br />flashing. Place through-wall flashing on sloping bed of mortar and cover with mortar .Seal <br />penetrations in flashing with adhesive/sealant/tape as recommended by flashing manufacturer . <br />Tumed -up and sealed end dams shall be provided at all flashing terminations. All laps and <br />terminations must be fully sealed, minimum lap of 2 inches. <br /> <br />C. Install flashings as follows: <br />1. At lintels and shelf angles, extend flashing a minimum of 4 inches upward into masonry at <br /> each end to forma dam. Extend flashing from exterior face of outer wythe of masonry, <br />through the outer wythe, turned up in the cavity a minimum of 8 inches, and then through the <br />inner wythe to within 1/2 inches of the interior face of the exposed masonry wall. Where <br />interior surface of inner wythe is concealed by furring, carry flashing completely through the <br />inner wythe and turn up approximately 2 inches, unless otherwise indicated. <br />2. At heads and sills, extend flashing as specified above unless otherwise indicated, but turn up <br /> ends not less than 2 inches to form a pan. <br />3. Interlock end joints of ribbed sheet metal flashings by overlapping ribs not less than 1- ½ <br /> inches or as recommended by flashing manufacturer and seal lap with elastomeric sealant. <br /> <br />D. Install weep holes in the sill and head joints in exterior wythes of the first course of masonry <br />immediately be]ow and above embedded flashings. Space weep holes per Drawings or 16 inches <br />o.c. unless shown otherwise. <br /> <br />E. Install reglets and nailers for flashing and other related construction where shown to be built into <br />masonry. <br /> <br />F. Do not cross bed mortar at flashing areas. <br /> <br />3. 12 FILLING CELLS: <br /> <br /> <br />A. Where indicated at reinforced cells, fill cavities full height with concrete or grout. Install grout in <br />lifts not to exceed 48 inches. Ensure complete filling of cells and proper clearances of <br />reinforcement is maintained. Confirm that all cells are filled from top to bottom. <br /> <br />B. Where required for fire rating of concrete masonry units, install fire-resistant material to <br />completely fill open cells full height of wall, or to a minimum height of 36" above the adjacent <br />roof height. Provide verification openings at bottom of cells to ensure material fills cells <br />completely from top to bottom. Plug cells upon confirmation of material filling using a material <br />compatible with the fire rating of the wall. <br /> <br />C. Where concrete masonry units are used as backup for exterior wall, fill all open cells with foamed- <br />in- place block insulation. App]y in lifts not to exceed 12 ft., providing confirmation that all <br />cavities are filled from top to bottom. <br /> <br /> <br />3.13 REPAIRING, POINTING, AND CLEANING:
The URL can be used to link to this page
Your browser does not support the video tag.