<br />15080 - 5/10 <br />D. Drilling Fluid Recycling System: The drilling fluid recycling system shall separate <br />sand, dirt and other solids from the drilling fluid to render the drilling fluid re-usable. <br />Spoils separated from the drilling fluid shall be stockpiled for later use or disposal. <br />2.06 OTHER EQUIPMENT <br />A. Pipe Rollers: Pipe rollers shall be of sufficient size to fully support the weight of the <br />pipe while being hydro-tested and during pull-back operations. Sufficient number of <br />rollers shall used to prevent excess sagging of pipe. <br />B. Pipe Rammers: Hydraulic or pneumatic pipe rammers may only be used if <br />necessary and with the authorization of Engineer. <br />C. Restrictions: Other devices or utility placement systems for providing horizontal <br />thrust other than those previously defined in the preceding sections shall not be <br />used unless approved by the Engineer prior to commencement of the work. <br />Consideration for approval will be made on an individual basis for each specified <br />location. The proposed device or system will be evaluated prior to approval or <br />rejection on its potential ability to complete the utility placement satisfactorily without <br />undue stoppage and to maintain line and grade within the tolerances prescribed by <br />the particular conditions of the project. <br />2.07 PIPE AND FITTINGS - HIGH DENSITY POLYETHYLENE (HDPE) <br />A. High density polyethylene (HDPE) pipe used in directional drilling shall be as <br />specified herein. <br />B. Smooth wall high density polyethylene (HDPE) liner pipe shall be a Type III, Class <br />C, Category 5, Grade P 34; PE 3408; as defined in ASTM D1248. Minimum cell <br />classification, as given by ASTM 3350, shall be PE 335434C. Pipe shall meet the <br />standards of ASTM F714, as modified herein, including the "Governmental/Military <br />Procurement" sections. Minimum hydrostatic design basis shall be 1600 psi. In all <br />cases, hydrostatic design basis and pressure rating shall be as determined using <br />the methods of ASTM F714. Pipe of this type shall be butt-fusion welded at joints. <br />All welding of joints shall be in strict conformity with the recommendations of the <br />pipe manufacturer and performed by a firm or individual recommended in writing by <br />the manufacturer. <br />C. As a part of the shop drawing submittals, the Contractor shall furnish, signed by a <br />Florida Registered Engineer, all calculations to determine, the pipe thickness, SDR <br />rating, allowable stresses, in accordance with ASME B31.8, Table A842.22 and <br />recommended coating, as required by the manufacturer. <br />D. CONTRACTOR shall submit two spare transition couplings to the City as necessary <br />to allow two complete transitions from the directionally drilled HDPE to PVC pipe. <br />PART 3 - EXECUTION <br />3.01 GENERAL <br />A. The installation shall be coordinated with Miami-Dade County and any other agency <br />having jurisdiction over the area of work. The Contractor shall not begin work until <br />he has received permission from the City and the governing authority to do so. In <br />the event railroad companies, FDOT or governing agency require payment for any
The URL can be used to link to this page
Your browser does not support the video tag.