Laserfiche WebLink
AUTHORIZED FOR LOCAL REPRODUCTION STANDARD FORM 330 (6/2004) PAGE 6 <br />MANDATORY USE DATE OF FORM 6/2004 <br />E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT <br />(Complete one Section E for each key person.) <br />12. NAME <br />Armando Ramirez, P.E. <br />13. ROLE IN THIS CONTRACT <br />Electrical Engineer <br />14. YEARS EXPERIENCE <br />a. TOTAL <br />40 <br />b. WITH CURRENT <br />FIRM: 10 <br />15. FIRM NAME AND LOCATION (City and State) <br />F.R. Aleman & Associates, Inc. (Miami, Florida) <br />16. EDUCATION (DEGREE AND SPECIALIZATION) <br />B.S.E.E., University of Miami, Miami, Florida (1966) <br />17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE) <br />Professional Engineer, Florida No. 15746 (1972) <br />18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.) <br />Prof. Engineering. Laws and Regulations. <br />Lighting Seminars. Cooper Lighting. <br />Lighting Seminars. General Electric. <br />Lighting Seminar. Power and Lighting Sys. <br />Overhead Distribution FPL. <br />Transient Voltage Surge Suppressors. <br />Surge Protection services <br />19. RELEVANT PROJECTS <br />a. <br />(1) TITLE AND LOCATION (City and State) <br />I-75 (SR-93) at SR-222 (39 Ave), FDOT 2, Clay & Duval counties, FL <br />(2) YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />02/2013 -Present <br />CONSTRUCTION (If applicable) <br /> <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm <br />FRA served as the Engineer of Record/Designer for this Lighting Design. Lighting Design Plans were prepared for the mainline <br />including temporary lighting. The existing lighting is to be removed as a result of the widening of a portion of I-75 Northbound and Exit <br />Ramp to SR-222 and new lighting will be designed and installed within the project boundary to comply with FDOT lighting criteria. The <br />new lighting will be designed using conventional lighting Cobra Head fixtures. Mr. Ramirez is the Engineer of Record for this project <br />which consisted in re-designing a one mile segment of Street Lighting on I-75 south of SR 222 for the department of Transportation. <br />Voltage Drop Calculations were performed to maintain Voltage Drops below recommended values by FDOT. Computer Program was <br />used to determine required Luminaire Spacing, Mounting Height to achieve Lighting requirements. He has assisted Prime Consultant <br />and Electrical Contractor during Temporary Lighting facilities construction. Mr. Ramirez also revised all shop drawings related to the <br />lighting materials used on the project such as poles, luminaries, conductors, transformers etc. Contact: Kevin Tasillo P.E. (407) 426- <br />7390 <br />b. <br />(1) TITLE AND LOCATION (City and State) <br />SR-23 New Toll Road from SR 21 (Blanding Blvd.) to North of Argyle <br />Forest Blvd. Design-Build, FDOT 2, Clay & Duval counties, FL <br />(2) YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />08/2014- Present <br />CONSTRUCTION (If applicable) <br /> <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm <br />SR-23 is a 7.8 mile new toll facility being constructed in Clay and Duval Counties (Jacksonville Metro Area). FRA provided Lighting, <br />Signalization and ITS plans. Mr. Ramirez served as EOR for Lighting Design and provided power to all ITS devices which included 8 <br />CCTVs, 18 MVDSs, 5 TTSs, 5 DMSs, 21 Local Hubs and 1 Master Hub. FRA served as the Engineer of Record/Designer for this ITS <br />Design-Build project. We provided a Fiber Optic Cable (FOC) communication distribution facility (Trunk, Drop, and Lateral Cables), full <br />CCTV coverage of the project area, fiber optic communication to CCTVs, DMSs and TTSs, as well as Electrical Power Service to all <br />the proposed field equipment. FRA also provided lighting and signalization plans for this project. Mr. Ramirez is the Engineer of <br />Record for this project presently under construction. A total of 538 street lights and aluminum poles were called for in this project. 400 <br />watts High Pressure Sodium Vapor Mongoose type luminaries were proposed along the Main Trunk while 250 watts were proposed on <br />access ramps. Wall Mounted luminaries were also specified under five bridges. Voltage Drop Calculations were performed to maintain <br />Voltage Drops below recommended values by FDOT. Computer Program was used to determine required Luminaire Spacing, <br />Mounting Height to achieve Lighting requirements. Service Points were coordinated with corresponding electric utility to minimize <br />conductor sizes and conductor runs to make job more economical. Mr. Ramirez also revised all shop drawings related to the lighting <br />materials used on the project such as poles, luminaries, conductors, transformers etc. Contact: Jennifer Lewis, P.E. (407) 563-7101 <br />c. <br />(1) TITLE AND LOCATION (City and State) <br />SR-5/US-1 Reconstruction St. Lucie/Indian River Counties from North of <br />SR-713/Kings Highway (MP 20.928) to South of Oslo Road/CR 606(MP <br />1.856), FDOT 4; Indian River County, FL <br />(2) YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />2013 - Present <br />CONSTRUCTION (If applicable) <br /> <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm <br />Mr. Ramirez was involved in the preparation of lighting plans and the lighting design and analysis report for the addition of new lighting <br />from the US-1 Bridge at Old Dixie highway to South of Oslo Road in Indian River County. This project involved providing roadway and <br />sign lighting per FDOT and Indian River County requirements. Mr. Ramirez also coordinated with FPL for the addition of electric <br />service points and to resolve conflicts with existing overhead electric utility and other existing utilities. Contact: Mr. Ariel Milan, P.E. <br />(305) 670-2351 <br />d. <br />(1) TITLE AND LOCATION (City and State) <br />Final Plans Review (subs to multiple firms on consecutive contracts), <br />FDOT 4; Broward, Palm Beach, Martin, St. Lucie, and Indian River <br />(2) YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />2005 – Present <br />CONSTRUCTION (If applicable) <br />