Laserfiche WebLink
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S <br />QUALIFICATIONS FOR THIS CONTRACT <br />(Present as many projects as requested by the agency, or 10 projects, if not specified. Complete one Section F for each project.) <br />20. EXAMPLE PROJECT KEY NUMBER <br />3 <br />21. TITLE AND LOCATION (City and State) <br />SR 94 - Kendall Drive Improvements, Kendall, FL <br />22. YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />6/03/15-8/03/15 <br />CONSTRUCTION (If applicable) <br /> <br />23. PROJECT OWNER'S INFORMATION <br />a. PROJECT OWNER <br />Lennar Southeast Florida Division <br />b. POINT OF CONTACT NAME <br />Jose Iglesias <br />c. POINT OF CONTACT TELEPHONE NUMBER <br />305-559-1951 <br />24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost) <br /> <br />The subject project is located along State Road 94 (S.R. 94/S.W. 88th Street/Kendall Drive) in Kendall, Florida. More specifically, the <br />project initiates at the intersection of S.R. 94 and S.W. 162nd Avenue and extends 0.78 miles west along S.R. 94. The project begin and <br />end stations are 121+00 and 160+00, respectively, corresponding to a distance of approximately 4,100 feet (0.78 miles). <br />Currently, plans are underway to improve S.R. 94 within the project limits. As part of the improvements, the roadway will be widened <br />to include one additional lane in both the eastbound and westbound directions, bringing the total lanes in each direction to three. The <br />eastbound and the westbound roadways will be separated by a grass and/or concrete median. Additionally, the project will include <br />milling and resurfacing, new stormwater management system consisting of exfiltration trench system(s) and lighting. The exfiltration <br />trenches are planned in the median outside the existing roadway. <br />The field scope of services for the project included site reconnaissance, marking the field exploration locations, clearing underground <br />utilities, obtaining permits from FDOT District VI, maintenance of traffic (MOT), performing pavement cores, obtaining bulk samples <br />for resilient modulus testing and conducting Standard Penetration Test (SPT) borings/sampling. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />PSI furnished the drilling and engineering scope to provide geotechnical engineering recommendations for roadway widening, light <br />poles and the proposed stormwater management system. Also coordinated Falling Weight Deflectometer Testing to be performed <br />along the 4,100 feet span of roadway and embankment moduli parameters to be provided at various spans of the project. <br />PSI fees: $45,000 <br />25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT <br />a. <br />(1) FIRM NAME <br />Professional Service Industries, Inc. <br /> <br />(2) FIRM LOCATION (City and State) <br />Miami, FL <br />(3) ROLE <br />Geotechnical Engineering <br />