Laserfiche WebLink
T <br />SCOPE OF SERVICES FOR GEOTECHNICAL SERVICES <br />We are hereby requesting a proposal for percolation tests. The bore holes should be drill <br />as close to required location as possible. Tests should conform to the requirements of the <br />South Florida Water Management District "usual Open -Hole Test" and should be: <br />1- Fifteen (15) feet deep as measured from existing ground. Enclosed is a map with the <br />appropriate locations. <br />2- Drainage test must be witnessed by a Dade County DERM representative. <br />3- Testing consultant must identify and secure all the permits required prior to <br />conducting the proposed subsurface exploration within public right-of-way including <br />providing the required maintenance of traffic during testing. <br />4- Provide three drainage test reports outlining the test results and the hydraulic <br />conductivity (k- value) for each test and type of soils encountered during testing. <br />5- All reports must be signed and sealed by a Professional Engineer registered in the <br />State of Florida. Please submit a proposal at your earliest convenience. Note proposal <br />must be in agreement with Dade County Resolution R-275-92, and must include time <br />frame. <br />7 <br />