My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2004-680
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2004
>
Reso 2004-680
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 3:42:11 PM
Creation date
1/25/2006 1:57:38 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2004-680
Date (mm/dd/yyyy)
06/03/2004
Description
Approving Agmt. Awarding Bid No. 04-04-01 to Jade Communications Inc.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Category 6 Cabling System <br />Request for Proposal <br /> <br />City of Sunny Isles Beach <br />Confidential and Proprietary <br /> <br />11 TESTING <br /> <br />Testing of all newly installed cable channels shall be performed prior to system cutover. <br /> <br />11.1 COPPER TESTING <br />· All category 6 field testing shall be performed with an approved level II! balanced twisted-pair <br />field test device. <br />· All installed category 6 channels shall perform equal to or better than the minimum <br />requirements as specified by the table below: <br /> <br />Parameter 100MHz 200M Hz 250MHz 300MHz <br />(dB) (dB) (dB) (dB) <br />Insertion Loss 19.0 dB 27.4 dB 30.9 dB 34.1 dB <br />NEXT Loss 43.9 dB 39.3 dB 37.8 dB 36.6 dB <br />PS NEXT Loss 41.9dB 37.3 dB 35.8 dB 34.6 dB <br />ACR 24.9 dB 11.9 dB 6,9 dB 2.5 dB <br />PS ACR 22,9 dB 9.9 dB 4,9 dB 0.5 dB <br />ELFEXT 26,3 dB 20,3 dB 18.3 dB 16.8 dB <br />PS ELFEXT 23.4 dB 17,3 dB 15.4 dB 13.8 dB <br />Return Loss 14,7 dB 11,7 dB 10.7 dB 9.9dB <br />Propaaation Delav 528 ns 527 ns 526 ns 526 ns <br />Delav Skew 40 ns 40 ns 40 ns 40 ns <br /> <br />· Category 6 balanced twisted-pair horizontal and backbone cables, whose length does not <br />exceed 90 m (295 ft) for the basic link, and 100 m (328 ft) for the channel shall be 100 <br />percent tested according to ANSIITIA/EIA-568-B.1. Test parameters include wire map plus <br />ScTP shield continuity (when present), length, NEXT loss (pair-to-pair), NEXT loss (power <br />sum), ELFEXT loss (pair-to-pair), ELFEXT loss (power sum), return loss, insertion loss, <br />propagation delay, and delay skew. <br /> <br />TEST EQUIPMENT CRITERIA <br /> <br />· All balanced twisted-pair field testers shall be factory calibrated each calendar year by the <br />field test equipment manufacturer as stipulated by the manuals provided with the field test <br />unit. The calibration certificate shall be provided for review prior to the start of testing. <br />· Auto test settings provided in the field tester for testing the installed cabling shall be set to the <br />default parameters <br />· Test settings selected from options provided in the field testers shall be compatible with the <br />installed cable under test. <br /> <br />11.2 FIBER OPTIC TESTING <br /> <br />HORIZONTAL FIBER TESTING <br /> <br />· Fiber horizontal cables shall be 100% tested for insertion loss and length. <br /> <br />· Insertion loss shall be tested at 850 nm or 1300 nm for 50/125f,.lm and 62.5/125f,.lm multimode <br />cabling in at least one direction using the Method B (1-jumper) test procedure as specified in <br />ANSIITIA/EIA-526-14A. <br /> <br />· Length shall be tested using an OTDR, optical length test measurement device or sequential <br />cable measurement markings. <br /> <br />BACKBONE FIBER TESTING <br />· Fiber horizontal cables shall be 100% tested for insertion lo~s and length. <br />· Insertion loss shall be tested at 850 nm and 1300 nm for 50/1251lm and 62,5/125f,.lm <br />multimode cabling in at least one direction using the Method B (1-jumper) test procedure as <br />specified in ANSIITIA/EIA-526-14A. <br /> <br />SIB <br />
The URL can be used to link to this page
Your browser does not support the video tag.