My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2005-825
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2005
>
Reso 2005-825
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 10:15:50 AM
Creation date
1/25/2006 1:57:58 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2005-825
Date (mm/dd/yyyy)
09/08/2005
Description
– Ratify Agmt w/Siltek Group Inc., Construction of 181st Drive Active Park.
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />r\ <br /> <br />-~ <br /> <br />n <br /> <br />u <br /> <br />11 <br /> <br />u <br /> <br />n <br /> <br />u <br /> <br />n <br /> <br />LJ <br /> <br />('Sl <br /> <br />u <br /> <br />n <br />u <br /> <br />n <br /> <br />LJ <br /> <br />(l <br /> <br />LJ <br /> <br />n <br />u <br /> <br />r') <br />u <br /> <br />n <br /> <br />u <br /> <br />n <br /> <br />L.J <br /> <br />(I <br /> <br />u <br /> <br />n <br /> <br />Augercast Pile Analysis <br /> <br />The results of our analysis indicate that structural pile capacities on the order of 40 tons may be <br />supported on 14-inch diameter augercast piles installed to tip depths ranging from 33 to 35 feet <br />respectively below the existing ground surface. The actual depths should be expected to vary <br />depending on the drilling conditions encountered during installation of these piles. Due to the <br />soil conditions encountered at this site, we anticipate large grout takes in order to construct the <br />cast-in-place piles. The floor slab and other site improvements should also be structurally <br />supported on the pile foundation system. If capacities other than 40 tons are needed, we should <br />be notified so that we may provide the capacity analysis based on revised loading information. <br /> <br />The Florida Building Code (FBC) requires that any piles designed for greater than 40 tons should <br />be load tested in order to verify the pile capacity. Therefore, a pile load test will not be required <br />for this project as described in the FBC. <br /> <br />AUGERCAST PILE CAPACITY TABLE <br /> <br />Pile Depth Below All. Compr. All. Tension Minimum <br />Diameter Exist. Ground Capacity Capacity Grout Strength <br />(Inches) (Ft) (Tons) (Tons) (psi) <br /> (0.25 f ' c) <br />14 33-35 40 15 4000 <br /> <br />Pile Observations <br /> <br />We recommend that at least four production piles within the proposed residence be instaJled in <br />the presence of the Nutting project geotechnical engineer. Final pile installation criteria will be <br />provided at this time. It is important that the instaIJation of all piles be under the full time <br />observation of a representative of Nutting Engineers. <br /> <br />Pile Reinforcement <br /> <br />We recommend that at a minimum, one full length #6 reinforcing steel bar utilizing centralizers <br />be installed in each pile. Additional reinforcing may be required depending on the structural <br />engineer's requirements. <br /> <br />LJ We recommend that a structural engineer be retained to determine the spacing and locations of <br />the piles, and discussions should be initiated between the owners, structural engineer, contractor, <br />(\ and Nutting Engineers to provide detailed specifications for the foundation installation work. <br />u <br /> <br />n <br /> <br />LJ <br /> <br />(I <br /> <br />~NUTTING <br />,~ ENGI~~:~A~NC. <br /> <br />ESTASUSHED 1987 <br /> <br />5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.