Laserfiche WebLink
E <br />3.07 PLACING AND COMPACTING <br />A. Unless otherwise permitted, the work begun on any day shall be completed in <br />daylight of the same day. <br />B. Concrete is not to be placed until reinforcing steel, pipes, conduits, sleeves, <br />hangers, anchors and other work required to be built into concrete have been <br />inspected and approved by the Engineer. Remove water and foreign matter from <br />forms and excavation. All soil bottom for slabs and footings shall be approved by <br />the Engineer before placing concrete. <br />C. Transport concrete from mixer to place of final deposit as rapidly as practicable by <br />methods which prevent separation of ingredients and displacement of <br />reinforcement, and which avoid re- handling. Partially hardened concrete is not to <br />be used. <br />I. Concrete during and immediately after depositing shall be thoroughly compacted <br />by means of suitable tools. Internal type mechanical vibrators shall be employed to <br />produce required quality of finish. Vibration shall be done by experienced <br />operators under close supervision and shall be carried on long enough to produce <br />homogeneity and optimum consolidation without permitting segregation of the solid <br />1 06/07 03300 -9 <br />03 -4197 <br />D. "Cold joints" are to be avoided, but if they occur, are to be treated as bonded <br />construction joints. <br />E. At construction joints the surfaces of the concrete already placed, including vertical <br />and inclined surfaces, shall be thoroughly cleaned of foreign materials and <br />laitance, and weak concrete and roughened with suitable tools to expose a fresh <br />face. At least two hours before and again shortly before the new concrete is <br />deposited, the joints shall be saturated with water. After glistening water <br />disappears, the joints shall be given a thorough coating of neat cement slurry <br />mixed to the consistency of very heavy paste. The surfaces shall receive a coating <br />at least 1/8 -inch thick, well scrubbed -in by means of stiff bristle brushes whenever <br />possible. New concrete shall be deposited before the neat cement dries. <br />F. Deposit concrete to maintain, until the completion of the unit, a horizontal plastic <br />Vertical <br />surface. lifts shall not exceed 24- inches and preferably 18- inches. <br />G. Chutes for conveying concrete shall be of U- shaped designed and sized to insure <br />a continuous flow of concrete. Flat (coal) chutes shall not be employed. Chutes <br />shall be metal or metal -lined and each section shall have approximately the same <br />slope. The slope shall not be less than 25 nor more than 45 degrees from the <br />horizontal and shall be such as to prevent the segregation of the ingredients. The <br />discharge end of the chute shall be provided with a baffle plate or spout to prevent <br />segregation. If the discharge end of the chute is more than 5 feet above the <br />surface of the concrete in the forms, a spout shall be used, and the lower end <br />maintained as near the surface of deposit as practicable. When the operation is <br />intermittent, the chute shall discharge into a hopper. Chutes shall be thoroughly <br />cleaned before and after each run, and the debris and any water shall be <br />discharged outside the forms. Concrete shall not be allowed to flow horizontally <br />over distances exceeding 5 feet. <br />H. In thin sections of considerable height, concrete shall be placed using suitable <br />hoppers, spouts with restricted outlets, or otherwise, as required or approved. <br />I. Concrete during and immediately after depositing shall be thoroughly compacted <br />by means of suitable tools. Internal type mechanical vibrators shall be employed to <br />produce required quality of finish. Vibration shall be done by experienced <br />operators under close supervision and shall be carried on long enough to produce <br />homogeneity and optimum consolidation without permitting segregation of the solid <br />1 06/07 03300 -9 <br />03 -4197 <br />