My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2016-2619
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2016
>
Reso 2016-2619
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/14/2016 11:45:08 AM
Creation date
11/14/2016 11:45:02 AM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2016-2619
Date (mm/dd/yyyy)
10/20/2016
Description
5th Amd to Agmt w/Keith & Schnars, FPL Overhead to Underground Conv
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II. SCOPE OF SERVICES <br /> Task 1 Engineering <br /> Engineering Services: <br /> Subtask E.43—Input Existing Utilities <br /> The intent of this task is to locate existing features with a reasonable degree of accuracy so that <br /> proposed improvements can be designed to avoid conflict. Using test-hole information, in <br /> combination with plans, as-builts, and mark-ups from the individual utility providers,CONSULTANT <br /> shall input horizontal and vertical information into base-file for use in design plans. Once <br /> complete, (existing information compiled and input) the base-file will be re-circulated to utility <br /> providers to ensure existing utilities are properly represented. Minor corrections and details are <br /> expected. <br /> Subtask E.44—Utility Test-holes&Utility Targeting <br /> To ensure the accuracy of existing conditions, specific utilities will be physically located and <br /> identified with exact vertical and horizontal location designated. <br /> Subtask E.45—Prepare Plans for Construction <br /> Utilizing completed base-file, CONSULTANT shall prepare plans for the components necessary for <br /> undergrounding of utilities. Requirements of each utility will be identified and incorporated into <br /> proposed design. CONSULTANT shall coordinate underground conduit needs, locations,structure <br /> sizes, and above-ground equipment. In addition, CONSULTANT shall identify proposed <br /> easements required to accommodate additional above-grade conditions. CONSULTANT assumes <br /> all underground features to be located within the existing right-of-way. <br /> Using the updated plans to be provided by FPL, CONSULTANT shall modify their plans to reflect <br /> the FPL revisions. CONSULTANT modifications shall include relocation and/or addition of <br /> modified easements, equipment, conduits (size, location, & routing) and impacts to ductbank. <br /> Where necessary, CONSULTANT shall perform field reconnaissance for the purpose of siting <br /> easements within private parcels. CONSULTANT shall coordinate request for information and <br /> clarifications directly with FPL. CONSULTANT services include attendance of meetings related to <br /> coordination with FPL. <br /> Upon incorporating, proposed design features of proposed improvements will be distributed for <br /> final coordination and approval from each of the utilities and FDOT. In addition, CONSULTANT <br /> shall identify private improvements to be addressed within the project. CONSULTANT shall <br /> support the City's efforts to obtain approvals for improvements on private property. <br /> Professional Services Agreement Utility Undergrounding Consulting <br /> Project Location:Sunny Isles Beach,FL <br /> K&S Project 18073—Amendment No.9 <br /> September 21,2016-Page 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.