Laserfiche WebLink
<br />Request for Proposal- "Aquatic Entertainment Complex" <br />City of Sunny Isles Beach, Florida <br />November 8,2010 <br /> <br />e <br /> <br />received a preliminary response to this answers. However, the response does not provide sufficient <br />information to fully address some of the pertinent zoning requirements and we thereby reserve the <br />right to address these points with the City upon further negotiations. Thus, the zoning requirements <br />noted here, and potential variances, are not final but are assumed until further determination by the <br />City of the correct requirements. A copy of Addendum $ to the RFP that includes our questions to <br />the City and their initial response is attached as Exhibit "A." <br />2 I The calculations noted are based on the assumption that the developer will be able to calculate, <br />for zoning purposes, based on the entire site area. If necessary, the developer will agree to a <br />Declaration in Lieu of a Unity of Title in order to do so and the City will agree to such a calculation. <br /> <br />Refer to Drawing A-105 for Diagrams of Zoning Regulations vs. Proposed Building <br />Massing. <br /> <br />Justification for Variances: At this early stage of Schematic Design we have made <br />efforts to minimize variances but due to challenging aspect of the site and project <br />specific requirements there are several elements and/or areas in this Project that <br />require variances from the zoning regulations as established for the Town Center <br />District. Variances related to height, setbacks, floor area and certain architectural <br />design minimum standards will be required for this particular proposal. <br /> <br />The variances are required and justified for the following reasons: <br /> <br />e <br /> <br />1) A height variance will be required based on: i) The interior clearances typically <br />required for Aquarium type buildings to accommodate systems and <br />infrastructure; ii) Achieving a higher elevation in order to capture wonderful views <br />of the city, beach and Intracoastal waterway and minimize the visual impact of <br />the Collins Avenue overpass; and iii) Having the ability to incorporate a possible <br />future skywalk (towards the beach) in which case the structure will need to cross <br />the Collins Avenue overpass and meet FDOT height clearances. <br /> <br />2) A pedestal, tower and/or pedestal setback variance will be required on both sides <br />of SIB to accommodate the maximum amount of parking (at ground level) and <br />achieve the standard depth for the required commercial retail space. This will be <br />crucial for successfully leasing the retail spaces located within the parking <br />structure. In our design strategy we have pushed the building towards the SIB- <br />WB edge which is not likely to have any pedestrian activity (therefore not <br />requiring a colonnade frontage) and provided for a Plaza at SIB-EB that offers a <br />55' -0" setback. <br /> <br />3) A loading zone, parallel to SIB Westbound road, is required for delivery of large <br />equipment. This area has little to no pedestrian activity and is visually buffered by <br />the Collins overpass, thus making it the most desirable area for back-of-house <br />services and/or activities. <br /> <br />t <br /> <br />4) As of the Schematic Design concept we have successfully accommodated 308 <br />parking spaces, which is possible with variances as noted. <br /> <br />9 of 32 <br />