My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications Vol. II
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(09-09-01) Streetscape Improvements 175th Ter & 183rd St
>
Specifications Vol. II
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2011 11:13:16 AM
Creation date
5/12/2011 11:12:16 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Median Closure
Bid No. (xx-xx-xx)
09-09-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />.., <br /> <br />. <br /> <br />,.., <br /> <br />. Produce and supply concrete for the leveling pad meeting the requirements <br />of Section 347. Assume responsibility for performance of all testing required by <br />,., Section 346. Use Department approved mix designs. <br />. 548-2.2 Reinforcing Steel: Meet the requirements of Section 931 utilizing Grade 60 <br />[420] (Black) steel. <br />,., 548-2.3 Soil Reinforcement: For walls utilizing soil reinforcement, use reinforcement <br />. consisting of steel wire mesh, metal strips or structural geosynthetics as required for the <br />wall system chosen. <br />P'1 Use steel wire mesh and embedded loops shop fabricated from cold drawn <br />. steel wire meeting the minimum requirements of ASTM A 82, and weld into the finished <br />mesh fabric in accordance with ASTM A 185. Use steel strips hot rolled from bars to the <br />,., required shape and dimensions with physical and mechanical properties meeting <br />. ASTM A 572 [ASTM A 572M] Grade 65 [450] or as shown in the Contract Documents. <br />Use shop-fabricated hot rolled steel tie straps meeting the minimum requirements of <br />.., ASTM A 570 [ASTM A 570M], Grade 50 [345], or as shown in the Contract Documents. <br />. Ensure that steel reinforcing strips, tie strips, reinforcing mesh and <br />connectors used in permanent walls are galvanized in accordance with ASTM A 123 <br />..., [ASTM A 123M] or ASTM A 153 [ASTM A 153M], as applicable. <br />. Use structural geosynthetics made of polypropylene, select high density <br />polyethylene or high-tenacity polyester fibers having cross-sections sufficient to permit <br />r"'\ significant mechanical interlock with the soil/backfill. Use geosynthetics having a high <br />. tensile modulus in relation to the soil/backfill. Use geosynthetics having high resistance to <br />deformation under sustained long term design load while in service and resistant to <br />II ultraviolet degradation, to damage under normal construction practices and to all forms of <br />. biological or chemical degradation normally encountered in the material being reinforced. <br />Store the geosynthetics in conditions above 200F [- rC] and not greater than <br />II 1400F [60oC]. Prevent mud, wet cement, epoxy, and like materials from coming into <br />. contact with and affixing to the geosynthetic material. Rolled geosynthetic may be laid flat <br />or stood on end for storage. Cover the geosynthetic and protect from sunlight prior to <br />...., placement in the wall system. <br />. Carefully inspect all reinforcement, steel and geosynthetics to ensure they <br />are the proper size and free from defects that may impair their strength and durability. <br />II 548-2.4 Attachment Devices: Use soil reinforcement attachment devices as <br />. required by the wall system chosen. <br />548-2.5 Joint Materials and Filter Fabrics: <br />" 548-2.5.1 Horizontal Joint Filler: Use elastomeric or polymeric pads/fillers in <br />. all horizontal joints between precast components as recommended by the wall <br />manufacturer. Ensure that the pads are of sufficient size and hardness to limit vertical <br />II stresses on the pad and concrete surface and to prevent concrete to concrete contact at <br />. the joints. <br />548-2.5.2 Joint Covers: Cover joints and other wall openings with geotextile <br />.., fabric meeting the requirements of Section 985 and Type D-5 of the Design Standards, <br />. Index No. 199. Apply an adhesive approved by the Engineer to the back of the precast <br />component for attachment of the fabric material. <br />1"'"'1 548-2.5.3 Alignment Pins: Ensure that pins used to align the precast <br />. components during construction are of the size, shape and material required for the wall <br />system chosen. <br /> <br />r1 <br /> <br />. <br /> <br />r, <br /> <br />09/09 <br /> <br />01000-122 <br /> <br />03-4122.F <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.