My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications Vol. II
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(09-09-01) Streetscape Improvements 175th Ter & 183rd St
>
Specifications Vol. II
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2011 11:13:16 AM
Creation date
5/12/2011 11:12:16 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Median Closure
Bid No. (xx-xx-xx)
09-09-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />..., <br /> <br />. <br /> <br />..., <br /> <br />. <br /> <br />be requalified on an annual basis. If the liquid anti-strip agent has been modified then a <br />new sample shall be submitted to the Department and tested per 916-5.1. <br />916-5.3 Mix Design Verification: Inclusion of a liquid anti-strip agent on the QPL <br />does not guarantee that the anti-strip will be approved for use in an asphalt mixture. <br />Specifications may require subsequent moisture susceptibility testing per FM 1-T 283 for <br />the particular mix design. Results from this testing may indicate the need for a larger <br />dosage rate of anti-strip agent (up to 0.75 % maximum) or a different anti-strip agent to <br />meet the specification requirements. <br /> <br />II <br /> <br />. <br /> <br />.., <br /> <br />. <br /> <br />, <br />. <br /> <br />..., <br />. <br /> <br />923 WATER FOR CONCRETE-CHEMICAL REQUIREMENTS. <br />(REV 4-25-05) (FA 6-30-05) (1-06) <br /> <br />ARTICLE 923-3 (Page 803) is deleted and the following substituted: <br /> <br />.., <br />. <br /> <br />923-3 Chemical Requirements. <br />923-3.1 Testing: All chemical analysis or test shall be performed in accordance with <br />AASHTO T 26 or Standard Methods for the Examination of Water and Wastewater. <br />923-3.2 Reclaimed Water: Water from mixer washout and recycled wash water <br />shall be tested and approved before use and shall not exceed the following allowable <br />limits: <br /> <br />II <br /> <br />. <br /> <br />" <br />. <br /> <br />Chemical Test Maximum (%) <br />Equivalent Alkalis as (NazO + 0.658 KzO) 0.06 <br />Total Solids 5.00 <br />Total Chlorides as Sodium Chloride 0.05 <br />Sulfate as S04 0.30 <br /> <br />..., <br /> <br />. <br /> <br />.., <br />. <br /> <br />..., <br /> <br />923-3.3 All Other Sources: Water from all sources, other than public health <br />approved sources, shall be tested and approved before use and shall not exceed the <br />following allowable limits: <br /> <br />. <br /> <br />..., <br /> <br />Chemical Test Maximum (%) <br />Acidity or alkalinity calculated in terms of <br />calcium carbonate 0.05 <br />Total organic solids 0.05 <br />Total inorganic solids 0.08 <br />Total chlorides as sodium chloride 0.05 <br /> <br />. <br /> <br />..., <br /> <br />. <br /> <br />..., <br /> <br />. <br /> <br />,.., <br /> <br />. <br /> <br />,., <br />. <br /> <br />1"1 <br /> <br />. <br /> <br />,..., <br /> <br />09/09 <br /> <br />01000-174 <br /> <br />03-4122.F <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.