My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Bid No. 16-12-02 - New HVAC Chiller Systems for Pelican Community Park
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(16-12-02) HVAC Chiller Systems for Pelican Community Park
>
Bid No. 16-12-02 - New HVAC Chiller Systems for Pelican Community Park
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2017 4:26:01 PM
Creation date
2/15/2017 4:21:40 PM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
New HVAC Chiller Systems for PCP
Bid No. (xx-xx-xx)
16-12-02
Project Type (Bid, RFP, RFQ)
Bid
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />SUMMARY <br /> <br />The following calculations were performed for the Multistack ASP-60X Chiller Modules <br />in accordance to the 2014 Florida Building Code. <br /> <br />The purpose of the calculations is to provide a rational analysis showing that the unit will <br />maintain its integrity during a wind event. The calculations show the required amount of <br />screws it will take to transfer the wind loads to the unit’s base frame. These calculations <br />do not address the required connection of the unit to the roof curb and the main building <br />structure (by others). <br /> <br />Because we are not concerned with the serviceability of the units after the wind event, <br />deflection and stress checks were not performed for its components. The main purpose is <br />to provide screw and attachment requirements so that the unit does not come apart and <br />will be connected together adequately. <br /> <br />The following design parameters were used: <br /> <br /> 5/16”-18 bolts (Grade 5 SAE J429) by Fastenal and ¼” fillet welds. <br /> Side Panel of the unit is 20 gage steel <br /> Fan Panel of the unit is 20 gage steel <br /> Top Panel of the unit is 20 gauge steel <br /> Fy = 36 ksi min for all unit steel used (Fu = 58 ksi min) <br /> 175 miles per hour winds – 3 sec gust (Risk Category II) <br /> Exposure Category C <br /> Mean Roof Height above grade equal to 30 ft or less <br /> <br />Note: <br />Connection of unit to the curb and main structure are not included in these pages and <br />are designed by others. <br /> <br />During regular maintenance all screws and panels will be checked for corrosion. Any <br />corroded screws are to be replaced with one that is equivalent in durability and strength. <br />Any corroded panels shall be repaired and/or replaced with one that is equivalent in <br />durability and strength. All screws that are removed in order to access inside of unit must <br />be refastened. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Pelican Community Park <br />City of Sunny Isles Beach, FL <br />Page 2 of 19
The URL can be used to link to this page
Your browser does not support the video tag.