CALTRAN Sunny Isles Day Care Center <br />BIGINHRING��G p <br />Summary of Findings and Recommendations: <br />• This analysis contemplated the most conservative scenario of trip generation forecast rates for the Day Care <br />Center as well as applying reduction of pass by trips only to the previous bank that used to occupy 3 times the <br />proposed store -front area. The trip generation Analysis for the proposed Day Care Center concluded the <br />proposed Day Care Center could generated at least two times less traffic than might typically generated by the <br />previous Drive -In Bank in the same store - front. <br />• A level of services analysis was performed considering a conservative assumption that 70% of the day care <br />traffic will be originated at Collins Avenue. The LOS analysis concluded that the intersection of Collins Avenue <br />at NE 174" Street is currently operating at acceptable LOS "B" and will continue operating al the same LOS with <br />very insignificant increase in the overall control delay that cannot be perceived by drivers after including the <br />conservative trips estimated for the Day care Center. <br />• A review of the parking analysis considered that if 4 to 6 parking spaces that are assigned to the daycare facility <br />to process kids within 5 minutes will suffice to serve the expected traffic demand during drop off and pick up <br />periods: it is- important to-mention-that for this- type offacility -arrival to the daycare will be -non- recurrent -and — <br />discontinuous. <br />In summary, the proposed Sunny Isles Day Care Facility would not have an adverse impact on the surrounding roadway <br />network and /or affect other traffic generators. <br />Engineer's Certification <br />I, Juan S. Calderon, certifythat I currently hold an active Professional Engineers License in the State of Florida and I am <br />competent through education and experience to provide engineering services in the civil and traffic engineering <br />disciplines contained in this report. I further certify that this report was prepared by me or under my responsible charge as <br />defined in Chapter 61 G15- 18.001 F.A.C. and that all statements, conclusions and recommendations made herein are <br />true and correct to the best of my knowledge and ability. <br />Juan S. Calderon, P.E. PTOE <br />State of Florida Board of Professional Engineers, <br />Professional Engineer License No. 58569 <br />After reviewing our analysis, should you have any questions or comments, please do not hesitate to contact me at (786) <br />449 -5093. <br />1400 NW 107th Ave, Suite 209, Miami, FL 33172 Tel: 786- 456 -7700 Fax: 786- 513 -0711 Page 5 <br />www.caltran,qroup.com <br />