My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2012-1884
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2012
>
Reso 2012-1884
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2012 3:57:26 PM
Creation date
4/11/2012 11:40:44 AM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2012-1884
Date (mm/dd/yyyy)
03/28/2012
Description
1st Addendum to Agmt w/Craig A. Smith 174th St. Drainage Project
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Dependant on the findings, we will make a recommendation or recommendations to <br />proceed with a solution to the flooding problem being experienced in the identified area. <br />For example, if we determIne that the existing drainage inlets are interconnected with <br />piping and a positive outfall which are not working due to silt and debris clogging the <br />pipes, we will recommend maintenance to clear the pipes and relieve the flooding. If we <br />determine that a piping system does not exist and the area relies on an exfiltration <br />trench system which is clogged due to age and lack of maintenance, we may <br />recommend cleaning/rehabilitation of the system or installation of a new system. The <br />cost to identify possible solutions, make a recommendation and provide a <br />conceptual/preliminary design solution will be $2,500.00. <br /> <br />Total Cost for Phase 1 <br /> <br />$9.000.00 <br /> <br />Phase 2 <br />In an effort to provide you with some estimated costs associated with the solution to this <br />flooding problem, CAS is providing below some possible solutions and estimated <br />engineering and permitting costs associated with them. <br /> <br />Option 1 - Cleaning/rehabilitation of existing storm drain system (1900LF). <br />Engineering fee for coordination and direction to contractor-$2,500.00 <br /> <br />Option 2 - Cleaning/rehabilitation of existing exfiltration system. <br />Engineering fee for coordination and direction to contractor-$500.00 <br /> <br />Option 3 - Installation of exfiltration trench (200 LF) <br />Engineering fee to design and permit (incl. $1,000 for exfiltration test)- $4,000.00 <br /> <br />Option 4 - Connection to existing FDOT drainage system. <br />Engineering fee to design and permit - $8,000.00 <br /> <br />Option 5 - Construction of Storm Drainage Pipe System with outfall. <br />Engineering fee to design and permit - $25,000.00. <br /> <br />Phase 3 <br />In an effort to provide you with some estimated costs associated with the solution to this <br />flooding problem, CAS is providing below some possible solutions and estimated <br />bidding and construction costs associated with them. <br /> <br />Page 2 of 3 <br /> <br />." <br />C?, \'\",; <br />t....J ,~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.