My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2012-1925
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2012
>
Reso 2012-1925
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2012 3:22:50 PM
Creation date
7/11/2012 3:21:57 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2012-1925
Date (mm/dd/yyyy)
06/21/2012
Description
Awd Bid 11-10-02&Agmt w/Shiff Const Security Barrier @ Heritage Garage
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B. The manufactured framework shall be subjected to the Ameristar thermal stratification coating process (high - temperature, in -line, <br />multi- stage, and multi - layer) including, as a minimum, a six -stage pretreatment/wash and an electrostatic spray application of a <br />polyester finish. The topcoat shall be a "no -mar" TGIC polyester powder coat finish with a minimum thickness of 2 mils <br />(0.0508mm). The color shall be (specify Black. Bronze, White or Desert Sand). The stratification- coated framework shall be capable <br />of meeting the performance requirements for each quality characteristic shown in Table 2. <br />C. Material for fence pickets shall be 1" square x 0.062" thick extruded tubing. The cross - sectional shape of the rails shall conform to <br />the manufacturer's ForeltunnerTM design with outside cross - section dimensions of 1.75" square. The top wall and internal web of the <br />of the rail shall be 0.070" thick; the sidewalls shall be 0.070" thick for superior vertical load strength. Picket holes in the ForeRunner <br />rail shall be spaced 4.715" o.c., except for Invincible style 6' long, which shall be, spaced 4.98" o.c. Picket retaining rods shall be <br />0.125" diameter galvanized steel. Fence posts and gate posts shall meet the minimum size requirements of Table 1. High quality PVC <br />grommets shall be supplied to seal all picket -to -rail intersections. <br />D. All fasteners shall be stainless steel. Bracket to rail attachments shall be made using specially designed one -way tamperproof <br />security bolts with inverted "t- nuts ". Bracket to post connections shall be made using self - drilling hex -head screws. <br />E. Aluminum castings shall be used for all rings, post caps, finials, and miscellaneous adornments. <br />2.03 FABRICATION <br />A. Pickets, rails and posts shall be pre -cut to specified lengths. ForeRunner rails shall be pre - punched to accept pickets. <br />B. The rail inner slide shall be fully inserted into the rail outer channel to form the raceway for the internal retaining rod. Grommets <br />shall be inserted into the pre - punched holes in the rails, and pickets shall be inserted through the grommets so that pre - drilled picket <br />holes align with the internal raceway of the two -part ForeRunner rails. (Note: This can best be accomplished by using an alignment <br />template). Retaining rods shall be inserted into each ForeRunner rail so that they pass through the pre - drilled holes in each picket, thus <br />completing the panel assembly. <br />C. Completed panels shall be capable of supporting a 300 lb. load (applied at midspan) without permanent deformation. Panels shall <br />be biasable to a 25% change in grade. <br />D. Gates shall be fabricated using 1.75" sq. reinforced ForeRunner rail material, 1.75" sq. x .250" gate ends, and 1" sq. x .125" <br />pickets. All rail and upright intersections shall be joined by welding. All picket and rail intersections shall be joined by welding. <br />PART 3- EXECUTION <br />3.01 PREPARATION <br />All new installation shall be laid out by the contractor in accordance with the construction plans. <br />3.02 FENCE INSTALLATION <br />Fence post shall be spaced according to Table 3, plus or minus % ". For installations that must be raked to follow sloping grades, the post <br />spacing dimension must be measured along the grade. Fence panels shall be attached to posts with brackets supplied by the manufacturer. <br />Posts shall be set in concrete footers having a minimum depth of 36" (Note: In some cases, local restrictions of freezing weather <br />conditions may require a greater depth). The "Earthwork" and "Concrete" sections of this specification shall govern material <br />requirements for the concrete footer. Posts setting by other methods such as plated posts or grouted core - drilled footers are permissible <br />only if shown by engineering analysis to be sufficient in strength for the intended application. <br />3.03 FENCE INSTALLATION MAINTENANCE <br />When cutting/drilling rails or posts adhere to the following steps to seal the exposed surfaces; 1) Remove all metal shavings from cut <br />area. 2) Apply custom finish paint matching fence color. Failure to seal exposed surfaces per steps 1& 2 above will negate warranty. <br />Ameristar spray cans or paint pens shall be used to prime and finish exposed surfaces; it is recommended that paint pens be used to <br />prevent overspray. Use of non - Ameristar parts or components will negate the manufactures' warranty. <br />3.04 GATE INSTALLATION <br />Gate posts shall be spaced according to the manufacturers' gate drawings, dependent on standard out -to -out gate leaf dimensions and gate <br />hardware selected. Type and quantity of gate hinges shall be based on the application; weight, height, and number of gate cycles. The <br />manufacturers' gate drawings shall identify the necessary gate hardware required for the application. Gate hardware shall be provided by <br />the manufacture of the gate and shall be installed per manufacturer's recommendations. <br />3.05 CLEANING <br />The contractor shall clean the jobsite of excess materials; post -hole excavations shall be scattered uniformly away from posts. <br />Echelon 11 Specification Ameristar Fence Products <br />Rev. 11/08/2011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.