My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(12-10-01) Newport Fishing Pier and Restaurant Utilities
>
Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/30/2012 11:09:24 AM
Creation date
10/30/2012 10:30:48 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Newport Fishing Pier and Restaurant Utilities
Bid No. (xx-xx-xx)
12-10-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
217
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
points and property monuments, and shall make no <br /> b. locating all Underground Facilities shown changes or relocations without the prior written <br /> or indicated in the Contract Documents, approval of Owner. Contractor shall report to <br /> Engineer whenever any reference point or property <br /> c. coordination of the Work with the owners monument is lost or destroyed or requires relocation <br /> of such Underground Facilities, including because of necessary changes in grades or <br /> Owner, during construction, and locations, and shall be responsible for the accurate <br /> replacement or relocation of such reference points <br /> d. the safety and protection of all such or property monuments by professionally qualified <br /> Underground Facilities and repairing any personnel. <br /> damage thereto resulting from the Work. <br /> 4.06 Hazardous Environmental Condition at Site <br /> B. Not Shown or Indicated <br /> A. Reports and Drawings: Reference is <br /> 1. If an Underground Facility is uncovered or made to the Supplementary Conditions for the <br /> revealed at or contiguous to the Site which was not identification of those reports and drawings relating <br /> shown or indicated, or not shown or indicated with to a Hazardous Environmental Condition identified at <br /> reasonable accuracy in the Contract Documents, the Site, if any, that have been utilized by the <br /> Contractor shall, promptly after becoming aware Engineer in the preparation of the Contract <br /> thereof and before further disturbing conditions Documents. <br /> affected thereby or performing any Work in <br /> connection therewith (except in an emergency as B. Limited Reliance by Contractor on <br /> required by Paragraph 6.16.A), identify the owner of Technical Data Authorized: Contractor may rely <br /> such Underground Facility and give written notice to upon the general accuracy of the 'technical data° <br /> that owner and to Owner and Engineer. Engineer contained in such reports and drawings, but such <br /> will promptly review the Underground Facility and reports and drawings are not Contract Documents. <br /> determine the extent, if any, to which a change is Such "technical data° is identified in the <br /> required in the Contract Documents to reflect and Supplementary Conditions. Except for such reliance <br /> document the consequences of the existence or on such "technical data," Contractor may not rely <br /> location of the Underground Facility. During such upon or make any claim against Owner or Engineer, <br /> time, Contractor shall be responsible for the safety or any of their Related Entities with respect to: <br /> and protection of such Underground Facility. <br /> 1. the completeness of such reports and <br /> 2. If Engineer concludes that a change in the drawings for Contractor's purposes, including, but <br /> Contract Documents is required, a Work Change not limited to, any aspects of the means, methods, <br /> Directive or a Change Order will be issued to reflect techniques, sequences and procedures of <br /> and document such consequences. An equitable construction to be employed by Contractor and <br /> adjustment shall be made in the Contract Price or safety precautions and programs incident thereto; or <br /> Contract Times, or both, to the extent that they are <br /> attributable to the existence or location of any 2. other data, interpretations, opinions and <br /> Underground Facility that was not shown or information contained in such reports or shown or <br /> indicated or not shown or indicated with reasonable indicated in such drawings; or <br /> accuracy in the Contract Documents and that <br /> Contractor did not know of and could not reasonably 3. any Contractor interpretation of or <br /> have been expected to be aware of or to have conclusion drawn from any "technical data° or any <br /> anticipated. If Owner and Contractor are unable to such other data, interpretations, opinions or <br /> agree on entitlement to or on the amount or extent, if information. <br /> any, of any such adjustment in Contract Price or <br /> Contract Times, Owner or Contractor may make a C. Contractor shall not be responsible for <br /> Claim therefor as provided in Paragraph 10.05. any Hazardous Environmental Condition uncovered <br /> or revealed at the Site which was not shown or <br /> 4.05 Reference Points indicated in Drawings or Specifications or identified <br /> in the Contract Documents to be within the scope of <br /> A. Owner shall provide engineering surveys the Work. Contractor shall be responsible for a <br /> to establish reference points for construction which Hazardous Environmental Condition created with <br /> in Engineer's judgment are necessary to enable any materials brought to the Site by Contractor, <br /> Contractor to proceed with the Work. Contractor Subcontractors, Suppliers, or anyone else for whom <br /> shall be responsible for laying out the Work, shall Contractor is responsible. <br /> protect and preserve the established reference <br /> EJCDC C-700 Standard General Conditions of the Construction Contract. <br /> Copyright 132002 National Society of Professional Engineers for EJCDC. All rights resen'ed. <br /> 00700-13 <br /> 03/12 11-4179 <br />
The URL can be used to link to this page
Your browser does not support the video tag.