Laserfiche WebLink
AT&T NOTES:THE FOLLOWING REQUIREMENTS APPLY TO THE PLACEMENT OF CONDUIT WITHIN ROW BY ACONTRACTOR FOR UTILITY USE:1.48 HOURS PRIOR TO DIGGING, CALL 811 (SUNSHINE STATE ONE-CALL) TO OBTAIN THELOCATION(S) OF EXISTING UNDERGROUND UTILITIES BY THEIR UNDERGROUND UTILITIESLOCATOR.2.FOLLOW ALL FDOT MOT REQUIREMENTS WHEN EXCAVATING WITHIN FDOT ROW.3.CONDUITS FOR ATT USE SHOULD MEET THE FOLLOWING GUIDELINES:A.BE 4" GRAY PVC MINIMUM SCHEDULE 40 OR EQUIVALENT,B.HAVE TOTAL BENDS NOT TO EXCEED 180 DEGREES,C.BENDS TO BE LONG AND SWEEPING WITH A MINIMUM RADIUS OF 36",D.CONDUIT TO BE BURIED AT A MINIMUM DEPTH OF 24",E.CONDUIT TO BE SEPARATED FROM POWER/OTHER UTILITY CONDUITS BYA MINIMUM OF 3" OF CONCRETE OR 12" OF WELL-TAMPED CLEAN FILL,F.CONDUIT TO BE EQUIPPED WITH PULL STRINGS,G.&21'8,772%(%(6($/('3/8**('$7%27+(1'6:,7+(;3$1'$%/(255,*,'3/8*6H.CONDUIT JOINTS TO BE MADE WITH SLIP-ON SOLVENT-WELDED CONNECTIONS.KEITH and SCHNARS, P.A.18073.00CITY OF SUNNY ISLES BEACHCONDUIT PLACEMENTCITY OF SUNNY ISLES BEACHFLORIDAC - 153AT&T SUPPLEMENTARY INFORMATION