Laserfiche WebLink
partitioned or finished into separate rooms. LC3] <br /> 161.12 Subdivisions <br /> A. Minimum requirements. Subdivision proposals, including proposals for manufactured home <br /> parks and subdivisions, shall be reviewed to determine that: <br /> (1) Such proposals are consistent with the need to minimize flood damage and will be <br /> reasonably safe from flooding; <br /> (2) All public utilities and facilities such as sewer, gas, electric, communications, and water <br /> systems are located and constructed to minimize or eliminate flood damage; and <br /> (3) Adequate drainage is provided to reduce exposure to flood hazards; in Zones AH and AO, <br /> adequate drainage paths shall be provided to guide floodwaters around and away from <br /> proposed structures. <br /> B. Subdivision plats. Where any portion of proposed subdivisions, including manufactured home <br /> parks and subdivisions, lies within a flood hazard area, the following shall be required: <br /> (1) Delineation of flood hazard areas, floodway boundaries and flood zones, and design flood <br /> elevations, as appropriate, shall be shown on preliminary plats; <br /> (2) Where the subdivision has more than 50 lots or is larger than 5 acres and base flood <br /> elevations are not included on the FIRM, the base flood elevations determined in <br /> accordance with Section 161.5 B (1) of this ordinance; and <br /> (3) Compliance with the site improvement and utilities requirements of Section 161.13 of this <br /> ordinance. <br /> 161.13 Site Improvements, Utilities, and Limitations <br /> A. Minimum requirements. All proposed new development shall be reviewed to determine that: <br /> (1) Such proposals are consistent with the need to minimize flood damage and will be <br /> reasonably safe from flooding; <br /> (2) All public utilities and facilities such as sewer, gas, electric, communications, and water <br /> systems are located and constructed to minimize or eliminate flood damage; and <br /> (3) Adequate drainage is provided to reduce exposure to flood hazards; in Zones AH and AO, <br /> adequate drainage paths shall be provided to guide floodwaters around and away from <br /> proposed structures. <br /> B. Sanitary sewage facilities.All new and replacement sanitary sewage facilities,private sewage <br /> treatment plants (including all pumping stations and collector systems), and on-site waste disposal <br /> systems shall be designed in accordance with the standards for onsite sewage treatment and <br /> disposal systems in Chapter 64E-6, F.A.C. and ASCE 24 Chapter 7 to minimize or eliminate <br /> infiltration of floodwaters into the facilities and discharge from the facilities into flood waters, and <br /> impairment of the facilities and systems. <br /> FINAL Model FPM Ordinance: Zones A &V(April 3, 2017) 22 <br />