TESTING SERVICES, INC. <br /> T5�DA TON.GEORGIA AV <br /> 30 •P.O BOX 2041 ° <br /> PHOTON,GEORGIA 30 •FAX01 V <br /> PHONE:(706)226-1400•FAX'(706)226-6118 <br /> I CLIENT: ACT Global Sports REPORT NUMBER: 519271 <br /> 197 Boling Industrial Way LAB TEST NUMBER: 2321-8064 <br /> Calhoun,GA 30701 I DATE: May 20,2011 <br /> ITest Material: <br /> Turf ID Infill Sub Base <br /> I Blend FB Ultra+MN Ultra) 3.5Ibs/ft2 SBR Ambient Rubber mixed Concrete <br /> Blend(F13 with 1.51bs/f12 Silica Sand <br /> 1 Test Scope: Friable foam blocks are attached to a weighted platform and pulled over the playing surface in <br /> a prescribed manner.The weight of foam abraded away determines the relative abrasiveness <br /> of the surface. <br /> 1 Test Method: ASTMF1015-03:Standard Test Method for Relative Abrasiveness of Synthetic Turf <br /> Playing Surfaces <br /> I Test Equipment: Abrasiveness Test Platform: 8"(20.3 cm)X 8"(20.3 cm)X 0.25'(0.635 cm) <br /> 0.635 an Diameter Holes Centered 0.635 crn from Edge <br /> X%;X 2'X 2°Foam Square Retainers <br /> Weight of Platform:931 grams <br /> I Test Weight: 20 lb(9.072 kg)Flat Head as Per ASTM F355A <br /> Pull Cable/Changing Pulley: Attached to Operator Foot Restraint Parallel to the Surface <br /> Test Foam: Isocyanurate Friable Foam Blocks <br /> T(5.08 an)X 2°(5.08 cm)X 1"(2.54 cm) <br /> IDensity: 1.95 Iblft'(0,0312 glom') <br /> Test Procedure: Four test foam blocks were pre-weighed and recorded in grams.The four blocks were then <br /> I placed into the square retainers of the test platform.The test platform was then placed on the <br /> playing surface and the test weight centrically positioned on top.The loaded platform was <br /> • then pulled 18"(45.72 am)between 8 and 12 seconds across,against,across in succession <br /> without lifting the test platform so as to outline a'square"on the surface.The test foam blocks <br /> I were then removed and re-weighed in grams.The abrasive index was calculated by <br /> determining the weight loss for each set of four blocks in grams.The weight loss was then <br /> divided by 6.0 and multiplied by 100. <br /> 1 Test Results: The test was conducted at TSi laboratory on May 10,2011;76°F 65%RH <br /> Before Weight of All(4)Foam Blocks After Weight of All(4)Blocks <br /> I9.4198 grams 7.7509 grams <br /> Abrasive Index 1 28±2 <br /> IApproved By: <br /> I Ede Miles Jr VP <br /> Testing Services Inc <br /> I <br /> I OUR LETTERS AND REPORTS APPLY ONLY TO THE SAMPLE TESTED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL <br /> OR SIMILAR PRODUCTS. THESE LETTERS AND REPORTS ARE FOR THE USE ONLY OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND THEIR <br /> COMMUNICATION TO ANY OTHERS OR THE USE OF THE NAME TESTING SERVICES,Inc.MUST RECEIVE OUR PRIOR WRITTEN APPROVAL. THE REPORTS AND <br /> LETTERS,AND OUR NAME.OUR SEALS,OR OUR INSIGNIA ARE NOT UNDER ANY CIRCUMSTANCES TO BE USED IN ADVERTISING TO THE GENERAL PUBLIC. <br /> y ProGrass RFP No. 12-10-03 an awl 91 <br />