HomeMy WebLinkAboutExhibit E - Structural Bindert D+L= 605 Ibs UPLIFT= 1160 Ibs RESTROOM FACILITY ROOF LEVEL 52.01 SCALE: 1/4"=1'-0" ROOF NOTES- 1.- ROOF ASSEMBLY: D+L=1183 Ibs n UPLIFT=2465 Ibs\'I D+L =1631 Ibs UPL IFT =1820 Ibs p+L=935 Ibs UPL IFT =1040 Ibs D+L=163 Ibs p UPL IFT =1820 Ibs D+L=1183 Ibs /� UPLIFT=2465 Ibs PROVIDE PREFABRICATED WOOD TRUSSES SPACED AT 2'-0" c/c (U.O.N.) SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED Bl' A FLORIDA REGISTERED PROFESSIONAL ENGINEER. 2.- PLYWOOD SHEATHING- PROVIDE 5/8' PLYWOOD SHEATHING OVER ALL TRUSSES, NAILED WITH Sd SHANK NAILS (HOT DIPPED GALVANIZED) 's 4' OC ALL SUPPORTS. ALL STRUCTURAL LUMBER SHALL BE MINIMUM Not SOUTHERN PINE 3.- TRUSS LATERAL BRACING- PROVIDE PERMANENT LATERAL BRACING, SPACED AT 10'-0" c/c ALONG SPAN OF TRUSS_ EACH ROW OF LATERAL BRACING MUST BE CRSS -BRACED AT EACH ENP SEE DETAIL E/6-4.0 4.- FOR GENERAL STRUCTURAL NOTES, SEE SHEET 53.01 5.- FOR BEAM 4 TIE BEAM SCHEDULE, SEE SHEET 53.01 6.- ALL TRUSS TO TRUSS (WOOD TO WOOD) CONNECTIONS SHALL BE DESIGNED BY TRUSS MANUFACTURER / DESIGNER 7.- FINAL TRUSS SPACING SHALL BE FURNISHED BY THE TRUSS DESIGNER 8.- CONTRACTOR MUST COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS 2-#5, RESTROOM FACILITY (2INTERMEDIATE LEVEL 52.01 SCALE: 1/4"=1'-0" 3-#5. 3-#5. 2-05, RESTROOM FACILITY GROUND FLOOR PLAN 52.01 SCALE: 1/4"=1'-0" GROUND FOOR PLAN NOTES I: TOP OF SLAB ELEVATION AS SHOWN THUS „EL. 2.- TOP OF FOOTING ELEVATION = T.O. EXI5T'G FOOTINGS. TYPICAL UNLESS OTHERWISE NOTED THUS - 0 3: DENOTES EXISTING MASONRY BLOCK WALL TO BE REINFORCED AS INDICATED IN PLAN. 4.- FOR GENERAL STRUCTURAL NOTES, SEE SHEET 53.01 5.- FOR BEAM 4 TIE BEAM SCHEDULE, SEE SHEET 53.01 (O.- WF -30 DENOTES AN 30' WIDE x 12' DEEP CONCRETE FOOTING REINFORCED WITH 3-05 CONT. AND #5,912' TRANSVERSAL. WF -36 DENOTES AN 36' WIDE x 12' DEEP CONCRETE FOOTING REINFORCED WITH 4-05 CONT. AND 05612' TRANSVERSAL. DEMOLITION NOTE: REFER TO DETAIL A/5-4.01 PRIOR TO COMMENCING WITH DEMOLITION OF EXISTING STRUCTURE. RAI RODRIGUEZ ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C --- 100 99 0 z W o z 0 O 0 U z w o � Li —j _ U U � Q M 0 w Ir 0 W a_ IZ Is w La C)z z M cn w a a IQ REVISIONS: RESTROOM FACILITY FOUNDATION AND GROUND FLOOR ROOF PLAN SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 4930 S.W. 74TH Court Miami, Florida, 33155 DRAWN BY: PROJECT NO. DAIS 2154 Fax:(305)666-5259 " www.ddaeng.com 2022-42-B OF [:)+L= 605 s A O.N. UPLIFT= 116 lbs 1 c O B D+L =1183 lbs �• .� UPLIFT=2465 Ibs 4 R -I --+-- — — — — --+-- - II II II D +L =1251 Ibs UPLIFT= 1510 Ibs 11 + I 1 I 1 I I I I + T I PRE -FA IC D WOOD GI R TRUSS 1 D+L=720 Ibs T+1 I I I D+L=1l Ibs B I I A UPLIFT=810Ibs I I — I UPL I =1050 _ Ibs I I; I LU I I LIFT=1060 Ibs B [)+L=1251 Ibs W I I I I I I UPLIFT= 1510 Ibs_ + + j PRE -FAB CAT D WOOD GIR R_TRUSS j T I f l I I PL IFT =1850 Ibs 1 4- ' II II II '� D+L=1183 Ibs I I I I I I B UPLIFT=2465 lbs — - --+-- — — — — R -I --+-- �fp 1 D+L= 605 Ibs UPLIFT= 1160 Ibs RESTROOM FACILITY ROOF LEVEL 52.01 SCALE: 1/4"=1'-0" ROOF NOTES- 1.- ROOF ASSEMBLY: D+L=1183 Ibs n UPLIFT=2465 Ibs\'I D+L =1631 Ibs UPL IFT =1820 Ibs p+L=935 Ibs UPL IFT =1040 Ibs D+L=163 Ibs p UPL IFT =1820 Ibs D+L=1183 Ibs /� UPLIFT=2465 Ibs PROVIDE PREFABRICATED WOOD TRUSSES SPACED AT 2'-0" c/c (U.O.N.) SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED Bl' A FLORIDA REGISTERED PROFESSIONAL ENGINEER. 2.- PLYWOOD SHEATHING- PROVIDE 5/8' PLYWOOD SHEATHING OVER ALL TRUSSES, NAILED WITH Sd SHANK NAILS (HOT DIPPED GALVANIZED) 's 4' OC ALL SUPPORTS. ALL STRUCTURAL LUMBER SHALL BE MINIMUM Not SOUTHERN PINE 3.- TRUSS LATERAL BRACING- PROVIDE PERMANENT LATERAL BRACING, SPACED AT 10'-0" c/c ALONG SPAN OF TRUSS_ EACH ROW OF LATERAL BRACING MUST BE CRSS -BRACED AT EACH ENP SEE DETAIL E/6-4.0 4.- FOR GENERAL STRUCTURAL NOTES, SEE SHEET 53.01 5.- FOR BEAM 4 TIE BEAM SCHEDULE, SEE SHEET 53.01 6.- ALL TRUSS TO TRUSS (WOOD TO WOOD) CONNECTIONS SHALL BE DESIGNED BY TRUSS MANUFACTURER / DESIGNER 7.- FINAL TRUSS SPACING SHALL BE FURNISHED BY THE TRUSS DESIGNER 8.- CONTRACTOR MUST COORDINATE ALL DIMENSIONS WITH ARCHITECTURAL DRAWINGS 2-#5, RESTROOM FACILITY (2INTERMEDIATE LEVEL 52.01 SCALE: 1/4"=1'-0" 3-#5. 3-#5. 2-05, RESTROOM FACILITY GROUND FLOOR PLAN 52.01 SCALE: 1/4"=1'-0" GROUND FOOR PLAN NOTES I: TOP OF SLAB ELEVATION AS SHOWN THUS „EL. 2.- TOP OF FOOTING ELEVATION = T.O. EXI5T'G FOOTINGS. TYPICAL UNLESS OTHERWISE NOTED THUS - 0 3: DENOTES EXISTING MASONRY BLOCK WALL TO BE REINFORCED AS INDICATED IN PLAN. 4.- FOR GENERAL STRUCTURAL NOTES, SEE SHEET 53.01 5.- FOR BEAM 4 TIE BEAM SCHEDULE, SEE SHEET 53.01 (O.- WF -30 DENOTES AN 30' WIDE x 12' DEEP CONCRETE FOOTING REINFORCED WITH 3-05 CONT. AND #5,912' TRANSVERSAL. WF -36 DENOTES AN 36' WIDE x 12' DEEP CONCRETE FOOTING REINFORCED WITH 4-05 CONT. AND 05612' TRANSVERSAL. DEMOLITION NOTE: REFER TO DETAIL A/5-4.01 PRIOR TO COMMENCING WITH DEMOLITION OF EXISTING STRUCTURE. RAI RODRIGUEZ ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C --- 100 99 0 z W o z 0 O 0 U z w o � Li —j _ U U � Q M 0 w Ir 0 W a_ IZ Is w La C)z z M cn w a a IQ REVISIONS: RESTROOM FACILITY FOUNDATION AND GROUND FLOOR ROOF PLAN SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 4930 S.W. 74TH Court Miami, Florida, 33155 DRAWN BY: PROJECT NO. DAIS 2154 06 ;&A V D.D.A. ENGINEERS P.A. CONSULTING ENGINEERS 4930 S.W. 74TH Court Miami, Florida, 33155 Phone: (305)666-07-11 Fax:(305)666-5259 " www.ddaeng.com 2022-42-B OF 5,2.0 SHEETS G$NMAI, SAUC`I'UItAI, NOTES 1_ GENERAL= THE STRUCTURAL SYSTEM FOR THE BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, 2020 EDITION. THE STRUCTURE WAS DESIGNED TO BE SELF-SUPPORTING AND STABLE FOLLOWING INSTALLATION OF ALL COMPONENTS AS INDICATED IN THE DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE SEQUENCE OF ERECTION PROCEDURES (INCLUDING IMPLEMENTATION OF TEMPORARY SHORING, BRACING, ETC_) AND TO ENSURE SAFETY THROUGHOUT THE PERIOD OF CONSTRUCTION. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS IN CONJUNCTION WITH THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS TO COORDINATE LOCATION OF DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, REGLET5, BOLT SETTINGS, SLEEVES, DIMENSIONS, ETC. POTENTIAL CONFLICTS SHALL BE TRANSMITTED TO THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH THE WORK. CONTRACTOR TO PROVIDE ADEQUATE TIME FOR RESPONSE FROM ARCHITECT/ENGINEER, NO PENETRATION SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT A PREVIOUS WRITTEN APPROVAL OF THE ENGINEER OF RECORD. IF ANY ERRORS, OMISSIONS OR POTENTIAL CONFLICTS APPEAR IN THE DRAWINGS, SPECIFICATIONS, OR OTHER DOCUMENTS, THE CONTRACTOR MUST NOTIFY THE ARCHITECT AND ENGINEER, IN WRITING, OF THE SAME PRIOR TO PROCEEDING WITH THE WORK IN QUESTION. IN THE EVENT THAT THE CONTRACTOR FAILS TO GIVE NOTICE, OR PROVIDE SUFFICIENT TIME FOR A RESPONSE, CONTRACTOR 15 RESPONSIBLE FOR THE RESULTS OF SUCH ERRORS OR OMISSIONS, AND FOR ALL COSTS FOR RECTIFYING SAME AND FOR ANY DELAYS OR ANY OTHER COSTS INCURRED BY SAME, 2_ CONCRETE: ALL CONCRETE TO ATTAIN A MINIMUM ULTIMATE COMPRE551VE STRENGTH OF 5,000 R51 IN 28 DAYS, AGGREGATES TO BE CLEAN AND WELL GRADED, MAXIMUM 51ZE I' CONCRETE SLUMP= 3' MIN. TO 5' MAX. VERTICAL CONCRETE. DROP NOT TO EXCEED 8'. 3_ CONCRETE COVER -- TO BE AS FOLLOWS: BOTTOM TOP SIDES FOOTINGS 3' 2' 3" COLUMNS - - 15" BEAMS 1.5' 1.5" 1.5" SLABS 1' 1' 1" 4_ REINFORCING STEEL -- TO BE NE HIGH STRENGTH BILLET STEEL DEFORMED AS PER ASTM A-305, AND CONFORMING TO ASTM A-615, GRADE 60. LAP CONTINUOUS BARS 30-5AR DIAMETERS, UNLESS OTHERWISE NOTED IN PLANS. HOOK DISCONTINUOUS ENDS OF ALL TOP BARS. REINFORCING STEEL TO BE DETAILED AND FABRICATED IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE OF DETAILING REINFORCING CONCRETE STRUCTURES", AND THE ACI BUILDING CODE 318, LATEST EDITION. SUBMIT SHOP DRAWINGS FOR APPROVAL BY ENGINEER BEFORE FABRICATION. 5_ APPLICABLE CODE= - THE FLORIDA BUILDING CODE 2020 lith EDITION) AND ALL ITS REFERENCE[) STANDAIRDS - ASCE 1-16 ALL STRUCTURAL ELEMENTS, EXPOSED TO WIND, HAVE BEEN DESIGNED PER THE GUIDELINES OF THE ASCE 1-16 CODE_ WIND 5PEED =115 MPH. EXPOSURE = D RISK CATEGORY = l II ) Kd = 0.85 INTERNAL PRESSURE COEFFICIENT +/- 0.18 6_ SPECIALTY ENGINEERED SYSTEMS: ITEMS DESIGNATED ON DRAWINGS THAT REQUIRE DESIGN BY A SPECIALTY ENGINEER SHALL BE DESIGNED, DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE BASED ON LAYOUT AND CONFIGURATION AS SHOWN ON ARCHITECTURAL DRAWINGS. THE SPECIALTY ENGINEERED SYSTEM SHALL BE DESIGNED TO RE515T THE GRAVITY LOADS AND COMPONENT AND CLADDING WIND PRESSURES INDICATED ON THIS DRAWING. SHOP DRAWINGS AND CALCULATIONS SHALL BE SUBMITTED THAT ARE DATED, SIGNED AND SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF FLORIDA. SPECIALTY ENGINEERED ITEMS ON THIS PROJECT INCLUDE= a) WOOD TRUSSES. b) LOUVERS. c) PRECAST CONCRETE VENT I_ MASONRY= A. ALL CONCRETE BLOCK TO BE GRADE N-2, CONFORMING TO ASTM C-90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1,900 PSI, AND A PRISM STRENGTH OF 1,500 PSI (MINIMUM). MORTAR SHALL BE TYPE M, WITH A MINIMUM STRENGTH OF 2,500 P51 (USE PORTLAND TYPE CEMENT). TEST MASONRY UNITS AND MORTAR BY TESTING LAB AT A RATE OF EVERY 1,000 SQUARE FEET OF WALLS ERECTED. B_ MASONRY WALLS SHALL BE REINFORCED HORIZONTALLY WITH 8 GAUGE DEFORMED GALVANIZED STEEL, SPACED AT 16" C/C VERT. EXTEND HORIZONTAL REINFORCING 4' INTO ADJACENT COLUMNS. PROVIDE TRUSS TYPE FOR NON -REINFORCED MASONRY AND LADDER TYPE FOR REINFORCED MASONRY. C. FOR VERTICAL REINFORCEMENT, SEE SCHEDULE AND LAP 46 BAR DIAMETERS MINIMUM. PROVIDE FULL BED OF MORTAR FOR REINFORCED MASONRY. D. AT ALL INTERIOR NON-BEARING BLOCK WALLS, MUST PROVIDE A TIE- BEAM 8"x12" WITH FOUR #5 CONT. AND #3 TIES AT 48' C/C, E. PROVIDE CLEANOUTS WHEN GROUTING BLOCK CELLS, AND CLEAN OUT BLOCK CELLS OF ALL MORTAR DROPPINGS. MAXIMUM VERTICAL DROP FOR GROUTING 15 4'-0" F. AT THE END OF EACH DAY COVER ALL MASONRY WALLS. S STRUCTURAL STEEL -- SHALL CONFORM TO ASTM A441 OR A512 GRADE WITH A MINIMUM YIELD STRESS OF 50 KSI, DETAILED, FABRICATED AND ERECTED IN ACCORDANCE WITH "AI5C' SPECIFICATIONS, LATEST EDITION. STRUCTURAL TUBE SECTIONS SHALL CONFORM TO ASTM A500 GRADE B (fy = 4(o KSI). ALL TUBES TO BE CONCRETE FILLED. BOLTS SHALL CONFORM TO ASTM A325 OR ASTM A490, UNLESS OTHERWISE NOTED IN PLANS. SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATION. 9_ WELDING -- ALL WELDING TO BE DONE BY DADE COUNTY CERTIFIED WELDERS HOLDING CURRENT WELDING CERTIFICATES, AND MUST PRESENT SAME AT JOB 51TE AT ALL TIMES. ALL WELDING PER PLANS AND PER GUIDELINES OF THE AMERICAN WELDING SOCIETY 10_ SHOP DRAUIINGS= NO SHOP DRAWING SHALL BE SUBMITTED FOR ARCHITECT/ENGINEER'S REVIEW UNTIL AFTER THEY HAVE BEEN REVIEWED AND NOTED FOR CONSTRUCTION METHOD, DIMENSIONING, AND OTHER TRADE REQUIREMENTS BY THE CONTRACTOR, AND STAMPED WITH THE CONTRACTOR'S APPROVAL SEAL. ENGINEER ASSUMES NO RESPONSIBILITY FOR DIMENSIONS, QUANTITIES, ERRORS OR OMISSIONS, AS A RESULT OF CHECKING AND REVIEWING ANY SHOP DRAWINGS. ANY ERRORS OR OMISSIONS MUST BE MADE GOOD BY CONTRACTOR, IRRESPECTIVE OF RECEIPT, CHECKING OR REVIEW OF DRAWINGS BY ENGINEER, AND EVEN THOUGH WORK IS DONE IN ACCORDANCE WITH SUCH SHOP DRAWINGS. 11_ EPDXY 5ASED ANCHORS_ FOR ANCHORING REINFORCING STEEL OR RODS IN EXISTING CONCRETE USE: - NSE 2411 BY "HILTI" - POWER FAST BY "POWERS/RAWL" - ALLIED GOLD A-1000 BY "ALLIED FASTENER AND TOOL" - OR ANY OTHER AVAILABLE PRODUCT PROVEN EQUAL. DRILL HOLES 1/8" MIN, BIGGER THAN THE DIAMETER OF THE BAR OR THREADED ROD, THE DEPTH OF THE HOLES TO BE AS INDICATED IN PLANS BUT NEVER LESS THAN MINIMUM INDICATED BY MANUFACTURER ALL HOLES MUST BE THOROUGHLY CLEANED FROM DUST AND DRY BEFORE POURING THE EPDXY GEL. IN THE EVENT OF LOST OR MISPLACED DOWELS INSTALLATION, THE STRUCTURAL ENGINEER (OR REPRESENTATIVE) MUST INSPECT HOLES PRIOR TO BEGINNING OF EPDXY INJECTION AND BARS INSTALLATION. 12_ DETAILS AND SECTIONS -- ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL, AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, UNLESS A DIFFERENT DETAIL, OR SECTION, IS SHOWN, 13_ DESIGN LOADS_ WOOD TRUSSES DEAD LOAD = 25 PSF LIVE LOAD = 20 PSF P1kEFAt WOOD IrkusSES & GI1kDE1kS CONNECIroks SCHEDULE O +I'IO OnS $�p Y LESS O I WIS NOIiD �ONN9&Ok 4LOVOL9 LOAD► VALUES albs) NAIL 5 �t QU LIPADA AL �" A LOAD Pa4ll IL TO '4 L LA I AL, L AD lute] NDI�ULAk TO 'gyp O META 20 W/TSS 1450 340 195 (8)-10c1 x 11/2" NAILS FL 114-13 BO DETAL 20 2400 2000 1505 (15)-10c1 x 11/2" NAILS FL 11413 C�] 3 6 12" RT5-1 + 10'-4" 0 x 12 2-#S WIND LOAD PRESSURES FOR ROOFING DESIGN (ASD) ZONE PRESSURE I -l2 PSF 2e -113 PSF C3) -131 PF 2r -107 PSF NET WIND LOAD PRESSURES FOR TRUSS DESIGN (ASD) (GROSS PRESSURES HAVE BEEN REDUCED BY 5 PSF TO OBTAIN NET PRESSURES) ZONE PRESSURE JACK TRUSSES ALL OTHER TRUSSES 1 -61 PSF - 44 1=5F 02e -108 PSF -92 PSF C3) -132 PSF -01 PSF 2r -102 PSF -66 PSF WIND LOAD PRESSURE FOR WINDOWS, DOORS AND LOUVERS. (ALLOWABLE) (POUNDS PER SQUARE FOOT) +TOP OF $.$I gLEV, ZONE 0 ZONE5 AREA ��. �' POSITIVE INEGATIVE POSITIVE NEGATIVE No. 10 ft2 to 25 ft2 +413 - 53 +413 - 65 NOTES: L- ZONE ( 15 DEFINED AS ANY DOOR OR WINDOW WITHIN a =3'-O' FROM A Y CORNER OF THE BUILDING, ALL OTHER LOCATIONS ARE DEFINED AS ZONE 4 2,-VALUE5 INDICATED CAN BE INTERPOLATED. NOTE. THE WIND PRESSURES INDICATED ON THE TABLES ARE TO BE USED WITH LOAD COMBINATIONS OF A5CE-1-10 L1/4 L1/4 OR I L2/4 L2/4 OR CANT. WHICHEVER IS GREATER WHICHEVER IS GREATER "C" B R —1 TOP BAR I STOP BA BOTTOM BAR LAP 24 BAR DIA. INTERMEDIATE REINFORCING STIRRUPS AS SCHEDULED STD. HOOKS I I/2" COVER ALL SIDES 1 THRUOUT LI I L2 tE TYPICALAM DIAGRAM � BOTTOM RAR NOTES -- L- - "C" BARS ARE TOP BARS AT NON -CONTINUOUS ENDS. 2 - "E" BARS ARE TOP BARS OVER RIGHT INTERIOR SUPPORTS. 3.- TOP BARS CALLED FOR AS CONTINUOUS, WHEN SPLICED, SHALL BE SPLICED IN THE 1" 11DDLE THIRD OF THE SPAN. 4.- REFER TO INTERMEDIATE BEAM REINFORCING FOR ADDITIONAL REINFORCING. 5.- PROVIDE AT ALL NON-BEARING BLOCK WALLS, A TIE -BEAM Vx12" (MIN-AJJITH 2-S TOP ANP BOTTOM CONT., #3 TIES, 4 AT 12 "c/c EACH END, RAL. AT 45"c/c TIE -BEAMS MUST BE DOWELED INTO WALLS AT EACH END, AT INTERSECTIONS, AT INTERMEDIATE POINTS. (o.- PROVIDE 2-#5 x5' -O" CORNER BARS (EXTEND 30" IN EACH DIRECTION FROM CORNER) AT ALL NON-BEARING BLOCK WALLS. EE lYl rl tEA M SH 0 2r 2� Ol EI�IIi EE- EACH END. a EG- EAGN CORNER MAAK +TOP OF $.$I gLEV, SIDE (IN.) W x H AMWOkIdING StkkupS ��. �' +I' �' 2e EF� No. SPA IN�G T5-1 + V-0" 0 x 12 2-'S 2 -*5 I C�] 3 6 12" RT5-1 + 10'-4" 0 x 12 2-#S 2 -*5 U 3 Q 12" R5-1 +10'-4" 8 x 12 2-#6 2-#(o Ll 3 e 5" NOTE: VALUES INDICATED ARE NET UPLIFT. /-,4\UPLIFT DIAGRAM SCALE: N.T.S. RAI RODRIGUEZ ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C ----- 1 0 0 9 9 0 LL- z W o z o o Q0 z w 0 r J L.L. J __j _ U Q w L.L. m 0 V) w 0 w 0 M L0 w a a Q m Q 0 Q REVISIONS: cn w J STRUCTURAL GENERAL NOTES SCHEDULES AND DETAILS SCALE INDICATED CHECKED BY: ISSUE DATE; MAR 02/04/22 DRAWN BY; FPROJECT NO. DMS 2154 n2 -r 2r Ol 2e L I NOTE: VALUES INDICATED ARE NET UPLIFT. /-,4\UPLIFT DIAGRAM SCALE: N.T.S. RAI RODRIGUEZ ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C ----- 1 0 0 9 9 0 LL- z W o z o o Q0 z w 0 r J L.L. J __j _ U Q w L.L. m 0 V) w 0 w 0 M L0 w a a Q m Q 0 Q REVISIONS: cn w J STRUCTURAL GENERAL NOTES SCHEDULES AND DETAILS SCALE INDICATED CHECKED BY: ISSUE DATE; MAR 02/04/22 DRAWN BY; FPROJECT NO. DMS 2154 ,/ D.D.A. ENGINEERS P.A. CONSULTING ENGINEERS 4930 S.W. 74TH Court Miami, Florida, 33155 1 Phone: (305)666-07-1-1 Fax:(305)666-5259 " www.ddaeng.com 2022-42-B OF 53.01 SHEETS I% C 2x4 CRC BRACING 2x4 COT HORIZON LATERAI BRACING 2x8 (P_T_) x 0'-S" WITH C2)114" DIA_ TAPCONS � EMB_ 11/4" ) AT 4" c/c_ (3) 12d NAILS AT BRACE TERMINATING AT WALL (2) 10d NAILS EACH MEMBER 2"x4" CONT_ LATERAL WOOD BRACING NAILED TO BOTTOM CHORD AT PANEL POINT AT MAXIMUM 10'-0" SPACING OR LESS IF REQUIRED BY TRUSS ENGINEER 48" (OVERLAP 6 SPLICES) PRE-ENGINEERED WOOD TRUSS BOTT_ CHORD 5/8" PLYWOOD OVER TRUSSES HORIZON ISSUE DATE: MAR 02/04/22 DRAWN BY: PROJECT NO. DAIS 2154 SSS rINUOUS _ ° ° S WO AT 2-1 (T' 2x4 BRfi e H OD 24"c. 0d 1 'P_) - (4) 12cl NAILS 4 BRACE TERMIN AT GIRDER TRI, GIRDER TRUSS 2x4 CONTINUOUS HORIZONTAL LATERAL BRACING 10 SP_ 2'-0" c/c = 20'-0" (MAX_) TYPICAL PERMANENT LATERAL BRACING FOR TRUSSES NOTES: HORIZONTAL BRACING OF TOP AND BOTTOM CHORD= 1_ PROVIDE ONE ROW OF HORIZONTAL BRACING AS SHOWN EVERY 10'-0" OF SPAN OF TRUSS_ 2_ BRACING MEMBERS TO BE CONTINUOUS 2x4 WOOD MEMBERS AT SPLICE LOCATIONS, LAP BRACING MEMBERS OVER AT LEAST TWO TRUSSES_ ROSS C ING D I AGONAL BRAC ING: 1_ PROVIDE CROSS BRACING, AS 6HOWN, AT EACH END OF EACH ROW OF PERMANENT HORIZONTAL BRACING, AND AT NO MORE THAN 20'-0" SPACING IN DIRECTION OF HORIZONTAL BRACING_ 2_ BRACING MEMBERS TO BE 2x4 WOOD MEMBERS_ DETAIL OF PERMANENT LATERAL BRACING FOR TRUSSES SCALE: N.T.S. Sd RING SHANK 5/0" CDX CONC_ PLYWOOD-/ --A BEAM, SEE �1M 2x8 FACIA_ SEE ARCH'L PLYWOOD Sd RING SHANK EDGE HOT -D IPPE D GALVANIZED 6 4"r-Ir- RING "c/cRING SHANK STANDARD NOOK TOP OF TB SEE PLANS VERIFY WITH ARCH. DRAWINGS BLOCK WALL //--2- l(od NAILS AT FACIA_ WOOD TRUSS, 7 TYP_ SEE PLA PLYWOOD ROOFING NAILING PLAN \DETAIL �_02SCALE: N.T.S. 2x8 STRUCTURAL SUB -FASCIA ALL CONN_ W1 (4)- l(od NAILS CORNER OF ROOF TRUSSES B D E T A I L 63.02 SCALE: N.T.S_ ROOF TB RE INF_ SEE BEAM SCHEDULE ADD #3 C ADD 2 05 BOTT_ EXTEND (o" INTO WALL EACH END_ I. WINDOW OR DOOR OPENING I. A" TYPICAL CONC. HEADER DETAIL ABOVE WINDOW / DOOR OPENING RAI RODRIGUF� ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C ----- 1 0 0 9 9 ry 0 Li z W o z 0 O o U z w o rro J Li J _ U Q w Li m 0 0 w 0 W U) 0 0 M LO LSI Ei a a Q a a Q REVISIONS: cn J U) z cn = w 0 � o_ U STRUCTURAL GENERAL NOTES SCHEDULES AND DETAILS SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 DRAWN BY: PROJECT NO. DAIS 2154 �RUS 'c �lA I L S a •" 2x4 BRfi 10 SP_ 2'-0" c/c = 20'-0" (MAX_) TYPICAL PERMANENT LATERAL BRACING FOR TRUSSES NOTES: HORIZONTAL BRACING OF TOP AND BOTTOM CHORD= 1_ PROVIDE ONE ROW OF HORIZONTAL BRACING AS SHOWN EVERY 10'-0" OF SPAN OF TRUSS_ 2_ BRACING MEMBERS TO BE CONTINUOUS 2x4 WOOD MEMBERS AT SPLICE LOCATIONS, LAP BRACING MEMBERS OVER AT LEAST TWO TRUSSES_ ROSS C ING D I AGONAL BRAC ING: 1_ PROVIDE CROSS BRACING, AS 6HOWN, AT EACH END OF EACH ROW OF PERMANENT HORIZONTAL BRACING, AND AT NO MORE THAN 20'-0" SPACING IN DIRECTION OF HORIZONTAL BRACING_ 2_ BRACING MEMBERS TO BE 2x4 WOOD MEMBERS_ DETAIL OF PERMANENT LATERAL BRACING FOR TRUSSES SCALE: N.T.S. Sd RING SHANK 5/0" CDX CONC_ PLYWOOD-/ --A BEAM, SEE �1M 2x8 FACIA_ SEE ARCH'L PLYWOOD Sd RING SHANK EDGE HOT -D IPPE D GALVANIZED 6 4"r-Ir- RING "c/cRING SHANK STANDARD NOOK TOP OF TB SEE PLANS VERIFY WITH ARCH. DRAWINGS BLOCK WALL //--2- l(od NAILS AT FACIA_ WOOD TRUSS, 7 TYP_ SEE PLA PLYWOOD ROOFING NAILING PLAN \DETAIL �_02SCALE: N.T.S. 2x8 STRUCTURAL SUB -FASCIA ALL CONN_ W1 (4)- l(od NAILS CORNER OF ROOF TRUSSES B D E T A I L 63.02 SCALE: N.T.S_ ROOF TB RE INF_ SEE BEAM SCHEDULE ADD #3 C ADD 2 05 BOTT_ EXTEND (o" INTO WALL EACH END_ I. WINDOW OR DOOR OPENING I. A" TYPICAL CONC. HEADER DETAIL ABOVE WINDOW / DOOR OPENING RAI RODRIGUF� ARCHITECTS INCORPORATED 2121 PONCE DE LEON BLVD, STE, 1010 CORAL GABLES, FL. 33134 TEL: (305) 448-3373 FAX: (305) 448-3374 A A C ----- 1 0 0 9 9 ry 0 Li z W o z 0 O o U z w o rro J Li J _ U Q w Li m 0 0 w 0 W U) 0 0 M LO LSI Ei a a Q a a Q REVISIONS: cn J U) z cn = w 0 � o_ U STRUCTURAL GENERAL NOTES SCHEDULES AND DETAILS SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 DRAWN BY: PROJECT NO. DAIS 2154 D.D.A. ENGINEERS P.A. A DETAIL � CONSULTING ENGINEERS 4930 S.W. 74TH Court Miami, Florida, 33155 63.02 SCALE= N.T.S. Phone: (305)666-071-1 JFax:(305)666-5259 " www.ddaeng.com 2022-42-B OF 53.02 SHEETS PRE -FAB WOOD TRUSSES 624'r -Ir- SEE PLAN. STEEL TRUSS STRAP AS SCHEDULED RAI RODRIGU Ez ARCHITECTS l INCORPORATED 2121 DE 1-0, 1010 LU CORALC GABLES, B FL. VD533134 TEL: 305 448-3373 �' FAX: (305) 448-3374 w T_O_ WALL S"x12" (MIN.) GONG, X CAP W/205 CONT, A A C ----- 1 0 0 9 9 '-0" EL. +�I I o T.O. SLAB DURING DEMOLITION DO NOT CUT TIEBAR ENCOUNTERED IN ANY EXISTING TIE COLUMN OR REINFORCED MASONRY CELL. CHIP AROUND EXISTING REBAR EXPOSED LENGTH FOR FOR SPLIICINCx ER CONC. PAYERS TO Z W MATCH EXIST. � O EL_ 0'-011 x� L" EL. 0'-0" EL_ -1'-4" T.O. SLAB .....� T_0.FTG- /,4\ DEMOLITION =TCS_ /a\DEMOLITION DETAIL SCALE: 1/2"=1'-0" ROOFING SYSTEM OVER PLYWOOD SHEATHING OVER PRE -FAB WOOD TRUSSES 12 GONG, BLOCK WALL RE IF_ W/1-06632 "c/c_ GONG_ FOOTING WF -36, SEE PLAN. r4\S E C T I ON 5C,4LE-- 1/2"=1'-0" 12 1 PRE -FAB WOOD TRUSSES X24"c/c SEE PLAN. EL. +1'-6" T -O. WALL CONC. PAVERS TO MATCH EXIST S"x16" (MIN.) GONG_ CAP W/3#5 CONT - 0 CONC, BBLOCK WALL REIT. W/1-#5648 c/c EACH WALL. GONG, FOOTING WF -30, SEE PLAN, SECT 1 O N SC,4LE-- 1/2"=1'-0" ROOFING SYSTEM OVER PLYWOOD SHEATHING OVER PRE -FAB WOOD TRUSSES PRE -FAB WOOD TRUSSES s24"c/c SEE PLAN. SECT 1 O N 5C,4LE= 1/2"=1'-0" 191 EXISTING BLOCK WALL TO REMAIN_ SECT 1 O N 5C,4LE-- 1/2"=1'-O" STEEL TRUSS STRAP AS SCHEDULED EL_ +10'-4° T.O. BEAM EL_ +8'-0" T.O. TIE. BEAM EL_ 0'-0" T.O. SLAB 0 z 0 a 0 z w i U LIL 0 (10w 0 w (100 Of il- 0 M LO w N M Q REVISIONS: U) W U U Q Z U Q W M W z 0 1 0 Q o o Q0 o � J li Q 2 � U Q 0J w L in I w LV) z = w Q w M zZD ILLJ z cn J J 0� L.IL- 0 o � z � C)z U (n SPC H � J 1�NnS RESTROOM FACILITY SECTIONS SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 DRAWN BY: PROJECT NO. DMS 2154 �. D.D.A. ENGINEERS P.A. CONSULTING ENGINEERS 4930 S.W. 74TH Court Miami, Florida, 33H5¢I Phone: (305)666-0711 Fax:(305)666-5259 www.ddaeng.com 2022-42-B OF 54,01 SHEETS STEEL TRUSS STRAP CONCRETE TIE BEAM, AS SCHEDULED SEE PLAN_ EL_ +10'-4" CONCRETE ROOF ..... ...... TO- BEAM CONCRETE BEAM, SEE PLAN. LAN_ BEAM, SEE PLAN - :/Jj 3'-0" 3'-011 1L/ NEW GONG. BLOCK NEW BLOCK WALL. EL +S'-0" WALL. CONCRETE TIE TO- CONCRETE TIE CONCRETE TIE BEAM, SEE PLAN. CONCRETE ROOF BEAM, SEE PLAN. BEAM, SEE PLAN. EXISTING BLOCK EXISTING BLOCK BEAM, SEE PLAN. WALL TO REMAIN_ WALL TO REMAIN_ 1-#5 DROP INTOCONCRETE TIE 1-#5 DROP INTO EXISTING BLOCK BEAM, SEE PLAN_ EXISTING BLOCK CELL AND FILL CELL AND FILL WITH GROUT, SEE WITH GROUT, SEE PLAN.PLAN_ 1-#5 DROP INTO EXISTING BLOCK CELL AND FILL ING BLOCK WITH GROUT, SEE PLAN. WALL ING BLOCK - UEJALL EXISTING BLOCK WALL_ EXISTING GONG EXISTING CONC_ SIO LABTREMAIN. SLAB TO REMAIN_ FOOTING TO REMAIN_%01 EL 0'-0° FTNNC_ i OOII � TO- SLAB FT G NC_— OOINTO G TO REMAIN. �������;i%i%moi%�;�;ii�i��i%�;�;i%���� �;�;i%�;i%ii��i%moi%�;i%moi%�;%�i��. REMAIN. SECT 1 O N 5C,4LE= 1/2"=1'-0" 191 EXISTING BLOCK WALL TO REMAIN_ SECT 1 O N 5C,4LE-- 1/2"=1'-O" STEEL TRUSS STRAP AS SCHEDULED EL_ +10'-4° T.O. BEAM EL_ +8'-0" T.O. TIE. BEAM EL_ 0'-0" T.O. SLAB 0 z 0 a 0 z w i U LIL 0 (10w 0 w (100 Of il- 0 M LO w N M Q REVISIONS: U) W U U Q Z U Q W M W z 0 1 0 Q o o Q0 o � J li Q 2 � U Q 0J w L in I w LV) z = w Q w M zZD ILLJ z cn J J 0� L.IL- 0 o � z � C)z U (n SPC H � J 1�NnS RESTROOM FACILITY SECTIONS SCALE INDICATED CHECKED BY: ISSUE DATE: MAR 02/04/22 DRAWN BY: PROJECT NO. DMS 2154 �. D.D.A. ENGINEERS P.A. CONSULTING ENGINEERS 4930 S.W. 74TH Court Miami, Florida, 33H5¢I Phone: (305)666-0711 Fax:(305)666-5259 www.ddaeng.com 2022-42-B OF 54,01 SHEETS