Re: Consulting Engineering Services for Golden Shores Pump Station RehabilitationCover Letter and Executive SummaryRFQ No. 18-11-01
Dear Mr. Betancur:
A & P Consulting Transportation Engineers (APCTE) in association with our Team members is pleased to submit this Statement of Qualification / Technical Proposal to the City of Sunny Isles Beach for the Consulting Engineering Services for Golden Shores Pump Station Rehabilitation. Our Team recognizes the importance of the existing Storm Sewer Pump Station that serves the Golden Shores Neighborhood and the positive steps the City is taking to improve the performance of this structure. To accomplish this task, the City requires a technically proficient and committed partner with extensive experience delivering complex design of Storm Sewer Pumping Stations, including planning, design, permitting and post-design services. Such a partner must be familiar with the technical challenges of these types of projects; the APCTE Team is that partner. Our technical capabilities will ensure the development of a rehabilitation program that will guarantee the completion of this project in schedule and within the planned budget.
Our Team has already started the evaluation process, and as shown in this Technical Proposal, has already identified the most critical deficiencies of the Golden Shores Drainage System. A preliminary proposal on how to mitigate these deficiencies is already stated in this document for the City’s consideration. The Golden Shores Neighborhood drainage system is based on swales with catch basins located at several locations that collects runoff generated by roads and adjacent properties. The total drainage area estimated is approximately 70 Acres. It is observed that some of the existing inlets were recently replaced and upsized. These drainage structures are connected to a storm sewer transmission system, which ultimately discharges into the existing Stormwater Pumping Station. The existing Station is located at the northwest corner of this neighborhood and could be accessed through N. bay Road. The Pump Station has four (4) main structures: Trash Rack Structure, Wet Well, Control Structure and a Generator Room. There is also a level recording gauge installed at the trash rack structure. The stormwater is pumped to a drainage well located at the control structure. This well overflows into another existing drainage well that overflows into another drainage well, which is 200 feet from the station. The existing control structure has a weir that overflows into the Intracoastal Waterway.
Based on information provided by the City of Sunny Isles Beach, the existing drainage system provides the level of service required for this neighborhood and no flooding complaints have been reported. However, the entire drainage system, including the existing pumping station needs to be inspected, repaired and improved or retrofitted. Conditions of catch basins, drainage pipes, wells, pumps, electrical system, mechanical system and outfall structure will be accurately assessed, and relevant recommendations will be provided to the City. Our team will develop a complete rehabilitation plan to improve the conditions of the existing drainage system. At the pump stations site several deficiencies were observed including but not limited to:
SECTION C - COVER LETTER AND EXECUTIVE SUMMARY
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
2
• Existing driveway needs to be regraded based on FEMA Flood Elevation requirements• Existing drainage structures at the pump station site should be raised• Accessibility to the existing pump station equipment is from the top of the existing structures• Roof of the existing station is leaking• Existing Sluice Gate is leaking• There is no automatic control system to control the existing pump station • Scada system or similar needs to be added to the existing station• The existing back flow prevention (check valve) at the outfall pipe is not working
All of these deficiencies will be addressed, and several alternative solutions will be discussed with the City’s Project Manager through a Basis of Design Report (BODR) as APCTE has successfully done in the past for many projects. Cost and benefits of all alternatives will be documented in order to define the best rehabilitation solution for the Golden Shores Pump Station. Our Team has already developed four (4) preliminary rehabilitation alternatives that are described in Section D of this Technical Proposal:
• Alternative 1: Consists of refurbishing the entire building structure; installing two louver doors; replacement of metal roof and relocating generator outside the building. • Alternative 2: Consists of refurbishing the entire building structure; demolish electrical room; Installing one louver door; replacement of metal roof and relocating generator outside the building.• Alternative 3: Consists of refurbishing only the northwest portion of the building (Control structure); demolishing the above ground portion of the existing wet well structure and electrical/generator room and relocating generator outside the building. • Alternative 4: Consists of refurbishing only the northwest portion of the building (Control structure); demolishing the above ground portion of the existing wet well structure and electrical/generator room and relocating generator outside the building.
In order to successfully accomplish the proposed rehabilitation plan, we have assembled a Team based on proven records in delivering complex pump station projects. Our professionals will provide the City the expertise in all
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
3
required disciplines for this type of contract, including: Surveying, Geotechnical Investigation, Structural, Mechanical, Electrical, Civil and Hydraulic Engineering. Our Team is also capable of assisting the City in the procurement process and will provide Construction Administration and Inspection Services during the execution of this project. Our in-depth understanding of the City’s stormwater system and unmatched technical experience in the permitting process facilitates our streamlined approach to evaluate the entire drainage system serving the Golden Shores Neighborhood. We will assign our best engineers to develop technical solutions that meet the challenges of this project. The experience of the proposed task leaders of our team is summarized below:
Mr. Arnelio Alfonso, P.E., will serve as Project Manager. Mr. Alfonso has over 32 years of experience in stormwater management design and has successfully designed several complex stormwater pumping systems.
Mr. Antonio G. Acosta, P.E., C.G.C., will serve as Principal-in-Charge for the project. He will be responsible for the allocation of resources and ensuring that a quality product is delivered on time and within budget.
Ms. Angela Baron-Ruiz, P.E., will serve as Drainage Engineer for the rehabilitation of the drainage system and as a permit coordinator. Ms. Baron-Ruiz has also 10 years of experience in stormwater management system.
Mr. Eduardo Martinez, P.E., will serve as Electrical Engineer. Mr. Martinez has 39 years of experience as Electrical Engineer of several pump station projects as well as several projects for South/North/Central Miami Dade Waste Water Treatment Plants desgined at APCTE.
Mr. Osmany Alfonso, P.E., will oversee the Structural Design required for the pump station improvements. Mr. Alfonso has 22 years of experience in the structural engineering field and has been the Structural Engineer of Record for the design of several of the pump station projects designed at APCTE.
Mr. Lazaro Ferrero, P.E., will serve as Drainage Engineer for the stormwater pump station. Mr. Ferrero has also 32 years of experience in stormwater management system design and has been the Engineer of Record for the design of several of the drainage projects at APCTE.
Mr. Erik Sibila, P.E., M.S.C.E, C.G.C., will be in charge of the Construction Management of the project. Mr. Sibila has 14 years in the Construction Administration Field in major drainage and infrastructure projects, including several pump stations.
Our experience demonstrates that we meet the qualifications that are essential to overcome the challenges of the proposed improvements of the Golden Shores Pump Station Rehabilitation. Experience on projects like the rehabilitation
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
4
of several Pump Stations in Miami Dade County, the design and construction of the Miami Beach Convention Center Pump Station and the City of Miami Beach Crespi Blvd Pump Station illustrate APCTE’s Team proficiency to surpass expectations for these types of projects. These projects, just to name a few, are a testimony of our Team’s unmatched qualifications and dedication to deliver excellence.
EXPERIENCE IN SIMILAR PROJECTS
Project Client Design Cost Completed by
Rehabilitation of PS 351 MD WASD $187,000 2016
Stormwater Pump Station – C. Center City of Miami Beach $450,000 2018
Stormwater pump Station – Crespi Blvd City of Miami Beach $345,000 2015
Rehabilitation of PS 437 MD WASD $195,000 2016
Availability:APCTE has more than 85 local employees (26 Registered PE’s and 61 Graduate Engineers) dedicated exclusively to drainage, transportation and pipeline design projects. APCTE’s workforce and availability is high at this time since we are just finishing a big project which will be done prior to us obtaining the NTP for this project. We currently have 12 dedicated personnel in our Water Resources Department, 13 dedicated personnel in our Civil/Highway Department, 10 dedicated personnel in our Electrical, Lighting Department, 5 dedicated personnel in our Structural Department and 17 dedicated personnel in our Construction Engineering and Inspection Services Department. The amount of work currently available, and the manner in which APCTE effectively manages its time and resources, allows for every team member to be engaged with said projects and to assiduously dedicate themselves to new projects.
Why select the APCTE Team?
• Our experience as a team on the design of several stormwater pump stations. One of the pump stations completed by our firm was nominated by the CAACE as Project of the Year in 2013• Our in-depth knowledge of The City, DRER and SFWMD design requirements for Pump Stations.• Our knowledge of the scope of work of this contract, its challenges and its solutions.• Our ability to coordinate and expedite the permitting processes with the environmental and permitting agencies for stormwater pump station projects.• Our Team’s experience, awareness of key project issues, established working relationship with our sub-consultants.• Our commitment to provide the City of Sunny Isles Beach with construction documents that will, to the highest degree possible, avoid claims, supplemental agreements and construction delays.
We feel confident that we can successfully implement this project to meet the City’s expectations. It is our purpose to continue working in a partnership with your staff and deliver this project on schedule and within budget.
Sincerely,
Antonio G. Acosta, P.E., President APCTE
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
6
UNDERSTANDING OF SCOPE OF SERVICES
The City of Sunny Isles Beach sits along the Atlantic Ocean threatened by rising seas and major tropical storms. The sea level around the City has risen steadily in recent decades and flooding in the streets has become more frequent and severe. Most of the City sits just four to five feet above sea level, and on a foundation of porous limestone, making it especially susceptible to tidal flooding and surging oceans. In order to mitigate these nuisances, the City is taking positive and unprecedented steps to protect itself from sea level rise.
The Golden Shores Neighborhood is located on the northwest corner of the City of Sunny Isles Beach, bounded by the William Lehman Causeway on the north; 185th St on the south; Collins Ave on the east; and the Intracoastal Waterways on the west. This neighborhood is mainly residential and cover an area of approximately 70 acres. The existing drainage system is based on swales with catch basins located at several locations that collects runoff generated by roads and adjacent properties. It is observed that some of the existing inlets were recently replaced and upsized. These drainage structures are connected to a storm sewer transmission system, which ultimately discharges into the existing Stormwater Pumping Station. The existing Station is located at the northwest corner of this neighborhood and could be accessed thru N. Bay Road.
Existing Golden Shores Pump Station: The existing Pump Station has the following components:
Trash Rack Structure: This structure collects the stormwater from the Golden Shore drainage system and discharges into the station wet well. It has a steel trash rack that trap any floating debris carried carried by the water. Trash rack has visible corrosion issues.
Wet Well Structure: Wet well has two chambers; the bottom chamber includes all the influent and effluent pipes as well as pump intakes, while the top chamber includes pump motors, controls, electrical connections, etc. The two chambers are divided by a steel grate. Access to the wet well is from the top of the building thru a hatch. The top of the wet well is metallic and has leakage. There is an emergency by-pass sluice gate that discharges into the downstream structure; which is also leaking.
Pumps: The existing 2 pumps are axial pumps manufactured by Couch Pump Company. There are two sizes of pumps within the wet well. The larger pump is Model NW 320 x 20 with a nominal capacity of 12000 gpm. Pumps are installed in a steel casing that connects into the control structure via two check valves. According to the City’s staff, the existing pumps were recently refurbished.
Control Structure: This structure receives the storm water from the pumps and discharges by gravity in two drainage wells, one located at the bottom of the structure and the second located 200 feet from the pump station. The existing control structure has a weir that overflows into the Intracoastal Waterways via an outfall pipe. Back flows are prevented with a Tideflex valve.
Generator Room: This part of the building is also accessible from the top, thru a hatch. The existing generator is outdated and has a capacity of 252 KW. The City expressed its desire to move the generator outside the building. Most of the electrical control panels are inside the generator room. Issues of accessibility, safety and ventilation should be addressed.
Level Gauge: Located at the trash rack, records the water level upstream of the existing pump station.
SECTION D - PROJECT APPROACH AND UNDERSTANDING
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
7
Existing Drainage System Performance
Based on information provided by the City of Sunny Isles Beach, the existing drainage system provides the level of service required for this neighborhood and no flooding complains have been reported. However, the entire drainage system, including the existing pumping station needs to be inspected, repaired and improved or retrofitted. Conditions of catch basins, drainage pipes, wells, pumps, electrical system, mechanical system and outfall structure will be accurately assessed, and recommendation will be provided to the City.
List of Deficiencies Observed:
As a result of a field visit to the Pump Station site, our Team identified the following deficiencies: • Existing driveway needs to be regraded: Grade elevation of driveway need to be elevated to comply with FEMA Flood Elevation requirements and also to improve access from the north area of the station. • Existing drainage structures at the pump station site: There is an existing drainage manhole at the site that is part of the FDOT drainage system, this structure should be also elevated as requested by the City staff.• Trash Rack or Intake Structure: The existing trash rack is made of steel and has visible corrosion issues. A new trash rack made out Aluminum or Stainless Steel should be installed.• Accessibility to the existing pump station equipment: The existing structures have no access from driveways. Maintenance staff currenlty needs to access the building thru the access hatches at the top, which require safety equipment due to the height.• Roof of the existing station is leaking: Existing metal roof is in bad conditions and it is leaking. This roof needs to be replaced. • Existing Sluice Gate is leaking: There is an existing sluice gate that serves to by-pass the flow from the wet well to the weir structure when the pups are not working. This sluice gate is leaking and needs to be replaced as well.• Monitoring System: The existing pump station does not have an updated monitoring system according to the latest technologies. Station should be provided with a complete new automatized monitoring system that can send alert notices to smart phones and emails when there is a malfunction of the station. Monitoring System should be able to record and track the performance of the station. • Scada system or similar: The existing station should also be provided with a Scada system or a similar.• Drainage Wells: drainage capacity of existing drainage wells is reduced, therefore these wells need to be cleaned, evaluated and redeveloped if need.• Outfall Structure: The outfall structure is provided with a back flow prevention valve (TideFlex) that according to City staff is not working. Our Team will evaluate the conditions of this valve and propose a repair or replacement if needed.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
8
METHOD OF APPROACH TO THE PROJECT
Rehabilitation of Existing Pump Station
The goal of the APCTE Team is to provide a stormwater pump station that is both easily operated and maintained and consistent with the City’s quality standards. For this work, we have taken into consideration site and hydraulic constraints, and all key technical issues that apply to this particular pump station. Knowing that the hydraulic conditions define the flow and total dynamic head (TDH) conditions that will be required, if the decision is made to replace the pumps, then selecting the right pump will be critical. Noise levels will be measured to verify background noise during day and nighttime conditions. Acoustical features will be incorporated into the facility design to manage noise levels to the maximum extent possible. Another component of a successfully designed project is visually blending the infrastructure with the surrounding area. In a way this is more art than science, and involves the use of appropriate architectural and landscaping features to screen a facility from view and make it aesthetically pleasing. Equally important aspect is to consider maintenance and equipment removal. Our design approach to maintenance of equipment is to provide an adequate clearance between adjacent equipment, provide lifting capability for each piece of equipment that will need to be removed, establish a clear path to remove a given piece of equipment from the facility and provide easy access to frequent maintenance items such as lubrication points. Also, our team will recommend the City’s staff to establish a secure facility consistent with the City’s requirements. This can be accomplished by providing security cameras, fire detection and alarm systems.
Lastly, we will take into consideration the effects of Sea Level Rise. The City of Sunny Isles Beach is considered one of the most vulnerable areas to climate change and especially susceptible to impacts such as rising sea levels. To mitigate these effects, we will design the mechanical and electrical components of this pump station taking into consideration the potential of sea level rise to ensure that this facility will function properly for the estimated design life of the project.
The work to be performed includes site preparation, earthwork, storm drainage infrastructure cleaning and inspection, and refurbishing of the existing pump station. In addition to the construction related services, the project will require engineering design, permitting, surveying services, utility locations, landscape architecture, and potentially geotechnical services. The project needs to be substantially completed before the next rainy season. All required performance testing, training, installation certification, and acceptance by the City shall be performed prior to substantial completion. The storm water pump station design will follow federal, state and local laws to be in full compliance with the City’s RFQ, governmental ordinances and regulations.
To prevent flooding, the lowest elevation of the control panels will be evaluated and reset 2 feet above of the base flood elevation (BFE). These panels will include an emergency generator receptacle of sufficient amperage to allow operation of the pump station in the event of a power failure, and in addition it will include adequate space and connections to warrant the installation and integration of future SCADA equipment to be installed by others. Prior to installation, our team will coordinate the integration of the SCADA system with the City of Sunny Isles. The control panels will be screened, and the areas surrounding the control equipment will be beautified with a suitable landscape buffer. The control panels will have an enclosure that is being currently being designed by the City and it is expected to be complete during construction. We will coordinate the enclosure completion and installation with the City.
Our proposed design will include a new pump controller with local override capability. Normal pump station operation will be based on new transducer levels while float switches will be provided for back-up operation. We will propose a SCADA RTU enclosure, antenna and required devices to allow for remote monitoring and control of the pump station. RTU selection will be coordinated with the city to deliver real-time alarms via phone, text message, email, etc. Communication of the RTU with the SCADA computer system will be wireless via cellular radio unless the city has any copper or fiber optic network available in the area
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
9
Innovative Concepts / Rehabilitation Alternatives:
As a result of the analysis of all of current deficiencies, our Team has developed 4 different proposed alternatives. These alternatives are innovative concepts that will be discussed and evaluated with the City’s personnel to select what should be the best option for the proposed improvements of the Golden Shore Pump Station. Since this is just a preliminary analysis, more deficiencies can be added and these alternatives can be modified according to the City’s needs. Here are the proposed alternatives:
Alternative 1: Alternative 1 consists of refurbishing the entire building structure. This alternative will include the following improvements:
• Remove the metal roof on top of the existing wet well and the electrical/generator room and replace it with a new concrete slab and new access hatches.• Install a new stand-by generator with a sub-base fuel tank outside of the existing building at northwest side of the pump station. Sub-base tank will be sized as per City requirement for the number of hours required for continuous operation.• Convert the existing electrical/generator room into an electrical room only. • Replace the existing trash rack which is in poor condition due to corrosion.• Replace existing sluice gate.• Install two (2) new louver doors in front of the wet well and the electrical room to facilitate access for maintenance and operation to the both rooms.• The front exterior ladder will remain to maintain access to the roof as well as the handrail on the roof.• Raise the top elevation of the existing well structure northeast of the pump station site with a separate outfall.• Regrade the asphalt driveway area to a higher elevation, adjusting all existing top of structures.• Coordinate with FP&L to provide a dedicated electrical service.• Remove and replace the existing electrical equipment such as Main Disconnect Switch, Transfer Switch, Motor Pump Control Panel, etc.• Provide a new Motor Pump Control Panel with local override capability. Normal pump station operation will be based on new transducer levels while float switches will be provided for back-up operation.• Provide a SCADA RTU enclosure, antenna and required devices to allow for remote monitoring and control of the pump station. RTU selection and procurement will be coordinated with the City to deliver real-time alarms via phone, text message, email, etc. Communication of the RTU with the City SCADA computer system will be wireless via cellular radio unless the City has any copper or fiber optic network available in this area.
This option includes a minor demolition and maintaining the same electrical enclosures.(See rendering)
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
10
Alternative 2: Alternative 2 consists of refurbishing only the north portion of the building (Wet Well - Control structure) and demolishing the existing electrical/generator room. This alternative will include the following improvements:
• Remove the metal roof on top of the existing wet well and replace it with a new concrete slab and new access hatch.• Demolish existing Electrical/Generator room. • Install all new electrical equipment such as, Main Disconnect Switch, Transfer Switch and Motor Pump Control Panel on a free-standing structure at the south wall of the remaining building.• Install a new stand-by generator with a sub-base fuel tank outside of the existing building at northwest side of the pump station. Sub-base tank will be sized as per City requirement for the number of hours required for continuous operation. (Wet Well and Control structure).• Replace the existing trash rack which is in poor condition due to corrosion.• Replace existing sluice gate.• Install one (1) new louver door in front of the wet well. • The access hatch on top of the wet well and the front exterior ladder will remain to maintain access from the roof as well as the handrail on the roof.• Raise the top elevation of the existing well structure at the northeast of the pump station site with a separate outfall.• Regrade the asphalt driveway area to a higher elevation adjusting all existing top of structures.• Coordinate with FP&L to provide a dedicated electrical service.• Provide a new Motor Pump Control Panel with local override capability. Normal pump station operation will be based on new transducer levels while float switches will be provided for back-up operation.• Provide a SCADA RTU enclosure, antenna and required devices to allow for remote monitoring and control of the pump station. RTU selection and procurement will be coordinated with the City to deliver real-time alarms via phone, text message, email, etc. Communication of the RTU with the City SCADA computer system will be wireless via cellular radio unless the City has any copper or fiber optic network available in this area.
This option includes demolition and upgrade of all the electrical equipment to the lasted NEC version. (See rendering below).
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
11
Alternative 3: Alternative 3 consists of refurbishing only the northwest portion of the building (Control structure) and demolishing the above ground portion of the existing wet well structure and electrical/generator room. This alternative will include the following improvements:
• Demolish existing Electrical/Generator room and the above ground portion of Wet Well structure.• Install a new concrete slab on top of the wet well with an access hatch.• Install all new electrical equipment such as Main Disconnect Switch, Transfer Switch and Motor Pump Control Panel on a free-standing structure at the south wall of the remaining building.• Install a new stand by generator with a sub-base fuel tank outside of the existing building at northwest side of the pump station (Control structure). Sub-base tank will be sized as per City requirement for the number of hours required for continuous operation. • Replace the existing trash rack which is in poor condition due to corrosion.• Replace existing sluice gate.• Install a new exterior ladder at the west side of the control structure, to maintain access from the roof as well as the handrail on the roof.• Raise the top elevation of the existing well structure at the northeast of the pump station site with a separate outfall.• Regrade the asphalt driveway area to a higher elevation adjusting all existing top of structures.• Coordinate with FP&L to provide a dedicated electrical service.• Provide a new Motor Pump Control Panel with local override capability. Normal pump station operation will be based on new transducer levels while float switches will be provided for back-up operation.• Provide a SCADA RTU enclosure, antenna and required devices to allow for remote monitoring and control of the pump station. RTU selection and procurement will be coordinated with the City to deliver real-time alarms via phone, text message, email, etc. Communication of the RTU with the City SCADA computer system will be wireless via cellular radio unless the City has any copper or fiber optic network available in this area.
This option will have more demolition work, upgrade all the electrical equipment to the latest NEC version, and provide more accessibility to equipment. (See rendering below)
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
12
Alternative 4: Alternative 4 consists of refurbishing only the northwest portion of the building (Control structure) and demolishing the above ground portion of the existing wet well structure and electrical/generator room. This alternative will include the following improvements:
• Demolish existing Electrical/Generator room and the above ground portion of Wet Well structure.• Install a new concrete slab on top of the wet well with an access hatch.• Install all new electrical equipment such as Main Disconnect Switch, Transfer Switch and Motor Pump Control Panel on a free-standing structure at the south wall of the remaining building. • Install a new stand-by generator with a sub-base fuel tank outside of the existing building at northwest side of the pump station (Control structure). Sub-base tank will be sized as per City requirement for the number of hours required for continuous operation. • Replace the existing trash rack which is in poor condition due to corrosion.• Replace existing sluice gate.• Install a new exterior ladder at the west side of the control structure, to maintain access from the roof as well as the handrail on the roof.• Raise the top elevation of the existing well structure at the northeast of the pump station site with a separate outfall.• Regrade the asphalt driveway area to a higher elevation adjusting all existing top of structures.• Coordinate with FP&L to provide a dedicated electrical service.• Provide a new Motor Pump Control Panel with local override capability. Normal pump station operation will be based on new transducer levels while float switches will be provided for back-up operation.• Provide a SCADA RTU enclosure, antenna and required devices to allow for remote monitoring and control of the pump station. RTU selection and procurement will be coordinated with the City to deliver real-time alarms via phone, text message, email, etc. Communication of the RTU with the City SCADA computer system will be wireless via cellular radio unless the City has any copper or fiber optic network available in this area.
This option will have more demolition work, upgrade all the electrical equipment to the latest NEC version, and provide more accessibility to equipment. (See rendering below)
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
13
Selection of Best Alternative
In order to evaluate all proposed alternatives and their respective advantages and disadvantages in fair fashion, it is necessary to develop a scoring system that assigns a value to each of the many parameters. APCTE has developed a scoring matrix that will assist on the selection of the best alternative. Below is a preliminary version of that Matrix, which will be modified during the actual design phase of this project.
Rehabilitation of other elements of the Drainage System
Although the City of Sunny Isles Beach boasts an existing drainage system with the capacity required for the neighborhood it services, APCTE’s goal is to provide the most up-to-date and improved pump station that will cost-effectively endure for many more years to come. In order to do so, it is critical that the existing system be thoroughly analyzed and accurately assessed to evaluate their hydraulic and structural condition. The existing drainage wells and pipes should then be cleaned after which any necessary developments or rehabilitation can be undertaken for a complete and satisfactory new pump station.
The existing drainage system serving the Golden Shores Neighborhood is based on swales with catch basins located at several locations that collects runoff generated by roads and adjacent properties. It is observed that some of the existing inlets were recently replaced and upsized. These drainage structures are connected to a storm sewer transmission system, which ultimately discharges into the existing Stormwater Pumping Station.
Drainage Pipes
The existing system, mainly the pipes and drainage wells, must be inspected in order to acquire a sense of their current condition and what, if any, rehabilitation must be done. While there are certain structures and sections of the drainage that can be inspected visually, the most cost-effective and efficient method is to use a CCTV system that can record depth and physical location of any defects or obstructions that may be encountered.
The CCTV System consist of PIG (pipeline inspection gauge) with a camera and high-powered lights on a swiveling head connected to display equipment via long cable wound upon a winch that traverses the pipeline. Displaying in real-time what is encountered within the pipeline, it simultaneously records to an external source so that the footage can also be reviewed later.
This inspection will allow for the understanding of the condition of the existing drainage pipes and will provide the data for evaluation and desired improvements.
Hydraulic EvaluationThe existing drainage system will be evaluated using a computer Hydraulic Model ICPR in order to determine its capacity. The evaluation will be based on the Level of Service required for a residential neighborhood. Different design storms will be used according to the City standards.
CITY OF SUNNY ISLES BEACH FLOOD CRITERIA
LAND USE RAINFALL FREQUENCY FLOOD LIMIT
Residential and Commercial Areas 5-year To Crown of street, or to within 15 feet of a dwelling or other occupied building, whichever is lower
2-Lane roads in residential and commercial areas 5-year, except 10-year for a bridge or culvert in the canal system.To Crown of street
4-Lane roads in high density, high traffic areas 10-year To outer edge of traffic lanes
Private parking lots andSimilar paved areas 2 – year As per Section D-4 of Public Works Manual
These criteria are outlined in DRER’s Policy for Design of Drainage Structure.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
14
Cleaning and Video InspectionAfter an assessment of the existing system, it may be necessary to remove any accumulated sediment, trash, or other substances from various components of the storm drainage system. Some common pollutants found in storm drains include: trash and debris, sediments, oil and grease, antifreeze, paints, cleaners and solvents, pesticides, fertilizers, animal waste, and detergents. This cleaning is necessary to eliminate amount of pollutants, trash, and debris both in the storm drain system and in receiving waters. Clogged drains and storm drain inlets can cause the drains to overflow, leading to increased erosion. Cleaning increases dissolved oxygen, reduces levels of bacteria, and supports in-stream habitat.
One of the main methods of cleaning utilized in storm sewers is involves jet/vacuum vehicles which can be used to remove debris from stormwater catch basins and pipes. This equipment breaks up clogged/accumulated material with high-pressure water jets and vacuums the material from the sewer. Water used in storm drain cleaning must be collected and properly disposed of, typically at a sanitary wastewater treatment facility.
Pipe RehabilitationIf the drainage pipes are found to be in poor condition due to wear or structural damage, there are several methods that can be utilized depending on the condition or situation presented. The original assessment of the pipes should determine if there is any unwanted leakage, worn out joints, etc. A repair process can then be recommended. Below are some examples along with summaries of what the process entails.
1. Chemical Grouting: Ideally suited to stopping leakage and reducing soil loss, grouting consists of injecting a self-setting grout into structurally sound leaking joints or small wall cracks2. Sliplining: When existing capacity is sufficient, sliplining is a relatively cost-effective rehabilitation method in which a pipe is inserted into an existing line by either pulling or pushing continuous or short-length pipes.3. Cured-in-Place Pipe: A polyester flexible sock or sleeve impregnated with resin is inverted or winched into the pipe.4. Fold-and-Formed Pipe: This method uses deformation to reduce the pipe diameter of conventionally formed pipe. The new pipe is then pulled into the existing pipe in the manner of traditional sliplining. Once winched into place, the pipe is expanded back into its original shape, forming a close fit with the existing pipe.5. Pipe Bursting: Pipe bursting uses a pneumatic or hydraulic bursting mandrel to crush an existing pipeline while pulling a new pipe into place. The crushed pipe is forced into surrounding soils, acting as bedding material for the new pipe.
Drainage WellsBecause of the nature of drainage wells and their form of operation it is essential that the groundwater table be analyzed to determine if operation as is may be continued.
Cleaning of Drainage WellsThe well should have all retained water removed, so that it can be cleaned well physically. The well lining can be cleaned manually using a brush and chlorinated water, or by using jetting or surging techniques also applied for well development.
The reason drainage wells and its parts should be cleaned regularly is that when enough sediment flows into the dry well, it will begin to leach into the surrounding soil and affect the well’s capacity to filter and drain the water. When built-up sediment within a dry well is left too long, it will eventually degrade its performance and cause failure, even if the utility was sized and installed correctly. The drainage wells should be cleared of any debris or obstruction to ensure continued operation.
Redevelopment/RehabilitationWhen drainage wells are found to be in need of redevelopment to ensure proper operation, there are several methods that can be used to accomplish this.
• Over-pumping: This method entails pumping the well at a rate greater than in normal operation and generally develops the more permeable sections of the surrounding environment
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
15
• Surging: This very common method flushes water backwards and forwards, as to prevent any bridging behind the screen and moving fines through into the hole.• Jetting: This development method uses the injection of high-pressure air or water to break up any filter cake and agitate and flush the adjacent gravel pack or formation• Hydro-fracturing: This is a second level of development in which high-pressure pumps are used to inject fluid to overcome the overlying rock pressure and open up existing and new fractures that will enable water movement and filtration
Outfall Structure
The existing outfall structure includes a 24” pipe that discharges into the Intracoastal Waterways there is a back flow prevention valve (TideFlex) at the discharge point. Our Team will perform an assessment of this outfall and will propose recommendations to the City. As proof of our experience on this field; APCTE is currently in charge of the Outfall Assessment Program of FDOT-District Six and has evaluated close to 200 outfalls structures in Miami Dade County, most of them discharging into the Intracoastal Waterways.
Pipe conditions, environmental concerns, obstructions, presence of barnacle, back flows preventions, etc are among the parameters that should be evaluated in an outfall structure.
Outfall Rehabilitation:Based on preliminary observations of the existing outfall; the following recommendations will be considered as part of the rehabilitation of this system:
• Pipe Cleaning• Pipe Rehabilitation,• Barnacle Removal• Replacement of TideFlex Valve
IMPLEMENTATION OF THE REHABILITATION PROGRAM:
Basis of Design Report (BODR)
Our Team will develop the Basis of Design Report (BODR) as the first phase of this task. the BODR will include the analyses of the different alternatives of the rehabilitation of the existing pump station. every alternative will be associated to a cost of implementation. BODR will include activities such as: site review narrative, public involvement plan, field observations and conversations/interviews, site photographs, right-of-way designation / easement identification, identification of municipal jurisdictions and special requirements, identification of all permitting requirements, materials to be used for the improvements, environmental concerns, installation methods, etc. As a result, our team will develop the BODR, which will be submitted to the City for review and approval. The BODR will justify what should be the most cost effective solution for the rehabilitation of the Golden Shores Pumping Station.
Survey and Geotechnical Services
The APCTE Team will identify the additional survey and geotechnical services required after reviewing the survey and geotechnical data provided by the City if any. Our surveyor sub-consultant, Longitude Surveying will be tasked with reviewing and vetting the existing topographic survey data and providing any additional measurements necessary to complete the design. They will have the responsibility of reproducing or crating “As-Built” drawings of the existing station; which is one of the main tasks at the pre-design phase of this contract. They will also follow our construction crews
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
16
to prepare the “As-built” plans to be submitted to the City. Our geotechnical sub-consultant, Nadic Engineering Services will evaluate the existing geotechnical data and will make recommendations regardign the need for any additional data. At a minimum, the geotechnical investigation will identify soil types, soil characteristics and properties and provide geotechnical recommendations for engineering design, and ground water table elevation.
Design Phase
We will start the pump station design as soon as we receive the NTP from the City. The engineering drawings and specifications will be refined to include specific equipment, layouts, mechanical, electrical, structural, instrumentation and controls, and SCADA. The engineering documents and technical specifications will be presented to City’s staff for review and comments. Our team members will develop with the City an efficient procedure to carry out this review. We will be available for a design review with the City staff to go over the submittal and obtain comments from staff. The comments will be incorporated in the plans and at 60%, the plans are submitted to the permitting agencies for permit review and approval. Then, the pump station design will be advanced to the 90% level of completion. This level of completeness will include a more refined specific equipment, layouts, mechanical, electrical, structural, instrumentation and controls, and SCADA sufficient to allow the contractor to build the project. The 90% engineering documents and technical specifications will be presented to City staff for review and comments. After their review, their comments will be incorporated in the 90% plans. This task results in the preparation of complete design documents pending receipt of permitting documents. Once permit activities are completed, any changes to the drawings and specifications required for approval by the permitting agency will be incorporated into the engineering drawings and specifications. Thereafter, 100% signed and sealed construction plans will be finalized and submitted to the City electronically as well as hard copies to allow the commencement of construction.
Contract Documents
The APCTE Team will prepare a set of contract documents in compliance with the specifications established by the City of Sunny Isles Beach. In addition, all materials and workmanship shall meet the requirements of the latest editions of the following publications:
1. Miami-Dade County Public Works Manual “Design and Construction Standards;2. The Florida Department of Transportation “Standard Specifications for Road and Bridge Construction, and its supplements;3. The Florida Department of Transportation “Standard Plans for Roadway and Bridge Construction”;4. The Florida Department of Transportation “Structures Standards”;5. Miami-Dade Water and Sewer Department “Design and Construction Standard Specifications and Details”; and
Permitting
The APCTE Team has over 20 years of experience in procuring and obtaining Right-of-Ways (R/W) and permits within the Miami-Dade County and its Municipalities and regulatory agencies. We are intimately familiar with the permitting procedures, requirements and typical timeframes to obtain permits approval. Our approach for permit procurement is to provide early coordination with every applicable agency, including pre-permit review meetings and post-submission peer review meetings to facilitate permit approval, specifically within the City of Sunny Isles Beach.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
17
The following agencies have jurisdiction over the construction of the proposed stormwater pump station:
• City of Sunny Isles Beach• Miami-Dade County Department of Regulatory and Economic Resources (RER). • South Florida Water Management District. • Florida Department of Environmental Protection.• U.S. Army Corps of Engineers. • U.S. Environmental Protection Agency.
Our Team will assist the City in filling documents required to obtain all necessary approvals of Permitting Authorities having jurisdiction over the Project. To expedite the procurement of permits required for this project, which may have a significant impact in the critical path, we have prepared a permit matrix that includes all required permits and the corresponding jurisdictional agencies.
Procurement Phase
During the Procurement process, APCTE will assist the City in preparing the Bid Documents for the advertisement. Then reviewing the Bids and making recommendations to the City to select a contractor for the Pump Station Rehabilitation. Contractor’s Qualification, Historical Records, Similar Experience, Insurance, Bonding Capacity, etc will be carefully verified. Finally, the selection recommendation will be based on the lowest qualified bidder.
Construction Administration
During Construction, Our Team will provide Construction Administration and Inspection Services. The City will have our support to perform full construction management services for this project. Typical engineering services during construction to be provided under this contract include but are not limited to:
• Site Inspections• Documenting Project Activities with Photos and Daily Reports• Hosting Progress Meetings• Review of Shop Drawings • Respond to Requests for Information• Review Claims and Potential Change Orders• Review of Schedule of Values and Contractor Invoicing• Review Project Schedule• Review As-Builts• Review Contractor Quality Control Testing
The APCTE Team perfectly knows the construction management and related services needed. We are currently involved in several major programs performing the role of agency secondary staff and full construction management services. Furthermore, we have also provided engineering services during construction while serving as the Engineer of Record.
The APCTE Team will work with the City of Sunny Isles Beach to schedule the preconstruction meeting shortly after the project is awarded to the contractor. We will provide the contractor with the standard templates for all submittals (invoices, shop drawings, transmittals, schedules, 3-week look ahead, change orders, progress reports, among others); provide the contractor with the program construction protocols and procedures; define the project’s chain of command; review contract documents/specifications and plans
Request For Information (RFI): RFI’s are originated during the construction process when discrepancies arise between the construction documents and design drawings with the actual field conditions. Our team is committed to review and respond to any Request for Information in a timely matter. Through our significant expertise gathered in similar projects, we will provide the City with the right response to the contractors concerns effectively.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
18
Shop Drawings Review: Our team has a vast experience in processing and reviewing shop drawings, product data, and samples for all disciplines involved in this type of projects. We are committed to ensure that all requirements are addressed by the Contractor prior installation of any component. Our records of experience in reviewing shop drawings over the last decade reveals that the construction works are completed without any significant issues relating to the design/drawing which prevents significant exorbitant economic claims against architects, engineers, and contractors. We will ensure that all shop drawings are processed within five (5) days in accordance with the City’s standard procedures.
Weekly Construction Progress Meetings: We believe weekly construction progress meetings are the best mechanism to discuss and address all issues that arise during the project, and ensure smooth progression of the job. Our professionals are very much proactive in conducting the weekly construction meetings. We will discuss all aspects of the ongoing project including submittals, shop drawings, RFIs, change orders, as built and closeout documents. Meeting minutes will be prepared and distributed to all parties involved in the project to provide continuous tracking until construction is completed.
Review of Change Orders: Our team is uniquely prepared to assist the City with the review of Change Orders to protect the City’s best interest. We realize that these evaluations are among the most crucial components in the Construction Phase and we are committed to work closely with the City, to ensure that all concerns are addressed.
Site Inspections: Our team will conduct site visits as required by the City to guarantee that all aspects of the projects are performed as stated in the Contract Documents. Construction Observation Reports and project photos will be prepared for every Site Visit performed and distributed to the Department to document the progress of the Contractor and keep track of the project based on the approved Baseline Schedule. Site inspections will be coordinated with the City’s construction manager as required.
Project Closeout: When the project is nearing completion, our team will prepare a punch list documenting all the work that does not conform or satisfy the terms of the contract documents prior to perform the project closeout and commissioning. We will also ensure that the Contractor provides all the required warrantees on their project items, and that there are no outstanding claims with the City or internally with their sub-contractors. All project documentation including logs of quality control testing will be filed for the City’s records.
Agency Certification: The APCTE team will perform the following services for the City during the final certification phase of the contract:
• Attend Final Inspection of the project with applicable agencies and contractors• Prepare certification forms for all agencies and submit all pertinent documentation to any other governmental authorities• Others as required by the City of Sunny Isles Beach
PROJECT MANAGEMENT PLAN
Our Project Management Approach is to establish the project requirements; set the basis for controlling scope, schedule, and budget of the project tasks; and describe the principal responsibilities and authority of the project participants. Our Team understands the necessity of successfully completing project goals within the predetermined schedule and work program budget. Our experience working in pump station projects in the past, makes us comfortable enough to say that the communication lines required to establish good coordination with the City are already in place. Our Team will provide the City of Sunny Isles Beach with a qualified management and technical staff to develop a set of contract documents that will be functional, cost effective, biddable and maintainable. We will use “hands-on” Project Management approach to effectively satisfy the contract conditions. Our streamlined production oriented team with state of the art resources allows us to complete project assignments on a record time with a high level of technical and professional qualities.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
19
Upon receipt of the notice to proceed (NTP) the APCTE Team will schedule a meeting with the City Project Manager, to discuss the proposed scope of services and will go to the field to fine tune the different items included in the scope of services. This initial field review will include video recording/pictures of existing conditions to help in defining project issues and deficiencies. One week after the field meeting, the APCTE Project Manager, Mr. Arnelio Alfonso, P.E., will coordinate with the City’s Project Manager to finalize the scope. Described below is a set of management activities that the APCTE Team will deploy to manage this contract.
Project Kick-Off Meeting: We will begin with a kick-off meeting to identify the key participants, to discuss the project purpose and scheduling of the implementation conference will be the responsibility of our Project Manager, working in conjunction with the City of Sunny Isles Beach Project Manager.
Project Reporting: APCTE will distribute meeting minutes within 3 working days of the conclusion of any meeting. Action items resulting from the meeting will be identified, including a responsible individual for the action and a date when the action is to be completed. Action items will be entered into a tracking database and will be reviewed by the Project Manager on a weekly basis. Monthly status reports will be the primary method for officially communicating the status of the project. The preparation of these reports will be the responsibility of the Project Manager with support from the project staff. The report will include cost and schedule updates, variance analyses, recommended corrective actions, and updated forecast. The status report will also include an executive summary with narratives regarding the accomplishment for the month, projected activities for the following month, and identification of any issues that may have arisen along with suggested approaches and resolutions.
Project Coordination: Our team understands the importance of coordination with all project stakeholders – including affected stake holder and permitting agencies, among others – and the need to plan ahead for upcoming projects along the routes. The APCTE team members will be proactive in meeting and contacting any affected stake holders. This task’s scope of work includes Municipality/Agency Coordination, a Governmental Affairs Program, Industry Forums, public project webpage updates, and Schedule of Implementation, among others. The identification of permitting requirements in advance is also a critical effort our team members are very familiar with. With over 30 years of experience of coordinating, issuing and verifying permits for similar projects, the APCTE team brings unique knowledge of permitting requirements, processes and procedures, specifically relative to drainage and pump stations.
Sub-Consultant Coordination: APCTE planning, design and construction management capabilities have been augmented with local sub-consultants for surveying and geotechnical services and a public involvement firm. Each firm will be given a specific scope, budget, and schedule. Our Project Manager will meet with each sub-consultant on a monthly basis to coordinate key technical issues, schedule requirements, and upcoming work. If the sub-consultant falls behind schedule, the firm will be required to add staffing until the progress meets the schedule.
Budget Monitoring and Control
The APCTE Team will develop and implement a Project Cost Breakdown Structure (PCBS) based on a logical organization of the work with flexibility to adjust to evolution of the project. The PCBS will include all tasks and any overall management tasks, but will be primarily directed towards deliverable products. The PCBS will form the basis for identifying schedule activities and monitoring cost. The PM will identify Task Leaders responsible for administering each PCBS. For example, PCBS for each project will include each discipline, and the Task Leader will be responsible for that PCBS. We will also develop standard cost control reports for every level of the PCBS, consistent with the schedule and will track original budget, earned value, approved changes, current budget, current expenditures, estimate to complete, pending changes, and anticipated changes. The cost reports will compare planned versus actual expenses and will identify variance at the cost account level. Explanation of the variances will be the responsibility of the PCBS managers. Regular monitoring will allow the Project Manager to identify negative cost trends, determine the root cause of the variances, and establish corrective actions to rectify the situation.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
20
The APCTE Team recognizes that 90% of a project’s cost overruns and delays occur during the construction phase. As such, we have implemented a management system that aims to:
• Avoid claims during the Bidding and Design phases by performing constructability at the pre-design phases, and preparing detailed bid documents that contain clear project scopes, quantities and cost estimates.• Manage claims during the construction phase by performing claim analysis to identify opportunities for change orders, and claim mitigation measures that may include redesign, deletion of construction scope, and postponement of the projects if necessary.
We have successfully implemented this budget control system in our Needs Assessment Program (NAP) for other agencies, and have successfully procured and constructed projects with minimal change orders.
PROJECT SCHEDULE
The APCTE Team will develop a logical and achievable design schedule for each task/project assigned to us. Our team will meticulously review this schedule based on our manpower availability and ensure that the schedule is within the team’s capability. The Project Design Schedule (PDS) will be reviewed on a bi-weekly basis, as a product of project team coordination meetings. Some of the events/activities that must occur very early in the design process to comply with the schedule are:
• Project Kick-off Meeting• Survey of Existing Structure• Geotechnical Investigations• Basis of Design Report• Design Phase• Permits• Value Engineering Workshop• Procurement• Construction Phase
Beside these tasks, our team will prepare a full schedule in Primavera P6 or Microsoft Project containing the detailed breakdown of all project’s main phases: pre-design, design, permitting, procurement and construction. The schedule will be reviewed on a bi-weekly basis and adjusted as the project progresses.
QUALITY CONTROL PLAN
“Quality Assurance and Control begins with the APCTE Team’s commitment to the City to provide qualified professionals that are experienced in all required disciplines”. An important characteristic of a strong, functioning organization is the establishment of well documented procedures and means to ensure compliance with those procedures. Project Manager, Arnelio Alfonso, PE, will rely on Carlos Gil-Mera, P.E., to review APCTE’s corporate procedures, and the City-specific quality measures being implemented on APCTE’s current projects. They will adjust the procedures as necessary for this project and conduct regular audits to assess the degree of compliance. Carlos is well versed in QA/QC procedures and will help to ensure that proper communication and acceptable practices are used to warrant quality of the planning, design, and construction services. Continuous QA/QC through internal review efforts will be woven into the design process. In-house coordination meetings with all Team members will be frequent and will allow for continual review of progress. Below is our QA/QC process in details:
Design Quality Assurance (QA) / Quality Control (QC): The Team will prepare all documents in accordance the QA plan to assure accountability, accuracy, completeness, legibility, application of design criteria and best engineering practices. The plan specifically addresses the importance of accurate construction cost estimates throughout the design-build process. This plan emphasizes the Team approach to successful project development with the goal of producing a top quality project, on time and within acceptable budget constraints, and to minimize construction conflicts and assure
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
21
constructability. Copies of all QA/QC forms are located at the end of this section.
Project Schedule Quality Assurance (QA) / Quality Control (QC): The Design Project Manager will receive input from the various company support sections to ascertain the true and accurate time period required for each activity as well as the order of precedence of said activities. With this information in hand, the Design Project Manager will create the Project Schedule. Any subsequent changes to the Project Schedule must consider activity durations and order of precedence requirements; all changes must be approved by the Project Manager. It is the responsibility of the Project Manager to guarantee the Team adheres to the Project Schedule throughout the entire project. The Team will coordinate with The City early and often to obtain the requisite permits on this project. The APCTE Team has the experience and resources to effectively complete this project on or before the estimated completion date as demonstrated in previous projects.
Plans Quality Control: As per The Quality Control Plan, plans, specifications, and estimates will be independently checked by professionals other than those preparing them. The independent professionals will check to assure accuracy, completeness, legibility, proper application of engineering criteria and compliance with all applicable Manuals and Standards. The independent review will be documented in the project file and will be accomplished and reflected prior to the phase review submittal to Quality Control Engineer. The Project Manager is responsible for ensuring adherence to the Quality Control Plan.
Phase Submittal and Review Procedures: The Quality Control Plan will guide production of all plans and specifications. Quality Control will be part of the all production processes; initially by the Design Team. The routine Quality Control reviews will be performed to allow company units to provide their own input regarding the project plans at every step of the process. The Project Manager will submit the plans and specifications at each phase of completion. The Project Manager must solicit the involvement of any outside individual or agency that has a legitimate stake in the project. The Project Manager needs to anticipate the necessary involvement of outside groups and local governments throughout the life of the project. All plans, specification and estimates submitted for phase review will be reviewed for completeness and conformance to current Manuals and Standards. The technical accuracy for the design is the sole responsibility of the Design Engineer. The Company Review Team is required to review each phase submittal and inform the Project Manager, in writing, as to any questions or concerns that might arise. The Project Manager will also be informed in writing if no questions or concerns arise during the phase review process. The Project Manager will then distribute the Phase Review Document to the Quality Control Manager, as well as all other reviewers involved in the process; the information exchange between the reviewers and the rest of the Team will ultimately benefit the Project.
Review Schedules, Completeness and Motivation: The Quality Control Plan is intended to be a dynamic document, subject to change with the goal of promoting a quality result. To that end, it is essential that all plans, specifications and estimates fully comply with the completeness requisite for each phase. All reviews must also be complete, comprehensive and consistent with the requirements of that phase. All reviews will adhere to the allotted time to ensure that adequate time is given to all parties and so that they remain personally invested and motivated in creating a quality product.Constructability Reviews: In addition to the types of reviews mentioned prior, the plans will be reviewed specifically for constructability. This particular review provides assurance that what is designed is feasible from the perspective of constructability. Items to consider are location, traffic control plans, making use of conventional construction techniques and equipment and materials. Constructability will be reviewed by DMSI staff; their substantial experience in both design and construction makes them perfectly suited for this task.
Quality Control Organization: The Team’s organizational chart, included in this proposal, describes the authority, accountability, and responsibility of each member. Our QA/QC Manager will be Mr. Carlos Gil-Mera, P.E., who will ensure that each staff member that works on this project performs his or her duties to the highest level.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
22
A&P Consulting Transportation Engineers Corp. (APCTE), was established on January 1995, with its Corporate office located at 10305 N.W. 41st Street, Suite 115, Doral, Florida 33178 and is a local multi-disciplinary consulting engineering firm with their headquarters in Miami-Dade County, 100% of our employees live and work in the Miami Dade / Broward County limits. During the last 15 years, APCTE has expanded and developed a highly specialized expertise in infrastructure pipeline and pump station rehabilitation projects. Our qualifications and vast experience in pump station design and upgrades makes us one of the best candidates to provide the engineering services required by the City in this contract. The APCTE Team has a thorough understanding of the key project issues which focuses the rehabilitation of the pump station. We realize that every pump station design is unique with its own set of challenges and requirements. The APCTE Team is prepared to work with the City to deliver the highest quality product while minimizing costs. APCTE has more than 85 local employees (26 Registered PE’s and 61 Graduate Engineers) dedicated exclusively to infrastructure and pipeline design / transportation projects. APCTE’s workforce and availability is high at this tie since we are just finishing a big project which will be done prior to us obtaining the NTP for this project. We currently have 12 dedicated personnel in our Water Resources Department, 13 dedicated personnel in our Civil/Highway Department, 13 dedicated personnel in our Traffic Engineering Department, 10 dedicated personnel in our Electrical, Lighting Department, 5 dedicated personnel in our Structural Department, 17 dedicated personnel in our Construction Engineering and Inspection Services Department, as well as 13 dedicated personnel in our Administrative Department. APCTE will serve as the prime designer for this contract, and has been recently involved in the design of several D/B projects for the City of Miami Beach such as Washington Avenue, Nautilus Neighborhood, Lummus Neighborhood, Biscayne Point Neighborhood, S.E. Flamingo Neighborhood, Prairie Avenue, amongst others. Shown below are APCTE’s current Technical Certifications with the Florida Department of Transportation and Miami-Dade County.
GROUP 3-HIGHWAY DESIGN-ROADWAY3.1 Minor Highway Design3.2 Major Highway Design3.3 Controlled Access Highway DesignGROUP 4-HIGHWAY DESIGN-BRIDGES4.1.1 Miscellaneous Structures4.1.2 Minor Bridge Design4.2.2 Major Bridge Design-SteelGROUP 5-BRIDGE INSPECTION5.4 Bridge Load RatingGROUP 6-TRAFFIC ENGINEERING AND OPERATIONS STUDIES6.1 Traffic Engineering Studies6.2 Traffic Signal Timming6.3.1 Intelligent Transportation Systems Analysis and Design 6.3.2 Intelligent Transportation Systems Implementation6.3.3 Intelligent Transportation Traffic Engineering Systems CommunicationsGROUP 7-TRAFFIC OPERATIONS DESIGN7.1 Signing, Pavement Marking and Channelization7.2 Lighting7.3 SignalizationGROUP 10-CONSTRUCTION ENGINEERING INSPECTION10.1 Roadway Construction Engineering Inspection10.3 Construction Materials Inspection10.4 Minor Bridge and Miscellaneous Structures CEIGROUP 13-PLANNING13.7 Systems Planning13.5 Subarea/Corridor Planning
13.6 Land Planning/Engineering
13.7 Transportation Statistics
SECTION E - QUALIFICATION INFORMATION & ASSIGNED PERSONNEL
FLORIDA DEPARTMENT OF TRANSPORTATION
1.01 Urban Area and Regional Transportation Planning2.01 Mass Transit Program (Systems) Management2.02 Mass Transit Systems - Mass Feasibility& Technical2.04 Mass Transit Controls, Communications& Information Systems2.05 Mass transit Systems-General Quality Engineering3.01 Site Development and Parking Lot Design 3.02 Highway Design3.02a Minor Highway Design3.03 Bridge Design 3.04 Traffic Engineering Studies 3.05 Traffic Counts
3.06 Traffic Calming
3.07 Traffic Signal Timing
3.08 Intelligent Transportation System Analysis, Design,
& Implementation
3.09 Signing, Pavement Marking, and Channelization
3.10 Lighting
3.11 Signalization
4.01 Aviation Systems-Engineering Design
5.01 Port and Waterway Systems-Engineering Design
6.01 Water Distribution and Sanitary Sewage Collection
& Transmission Systems
6.02 Major Water and Sewer Pumping Facilities
6.03 Water and Sanitary Sewage Treatment Plants
8.00 Telecommunication Systems
10.01 Stormwater Drainage Design Engineering Services
12.00 General Mechanical Engineering
13.00 General Electrical Engineering
16.00 General Civil Engineering
MIAMI - DADE COUNTY TECHINCAL CERTIFICATIONS
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
23
APCTE Team is licensed, certified and permitted to do work in the State of Florida. Please see attached licenses and certifications for all of the team members.
To ensure the successful implementation of this challenging contract, APCTE has a combined local pump station design experience of more than 100 stations. Our qualifications and vast experience in pump station and pipeline design make us the ideal candidate to provide the services required by the City of Sunny Isles Beach in this contract. Within the last ten (15) years APCTE has designed several sanitary lift stations for M-D WASD. One example is the Convention Center Drive Pump Station: includes the design of a 80,000 G.P.M. Stormwater Pump Station. Other similar pump stations which have been designed by our firm include the total reconstruction and relocation of the Regional Pump Station #101, located in front of the Miami International Airport, that was replaced with a new state of the art station furnished with Variable Frequency Drive (VFD) pumps and electric generator for alternate power supply in case of a power outage. Palmetto Bay (Perrine/Cutler Ridge), Miami Gardens, and the Port of Miami. All of our pump station projects also included the relocation and/or upgrades of the sewer collection systems serving the project area. In fact, APCTE has designed over 40,000 LF of sewer collection and transmission systems, including pipes ranging from 6” to 48”, and several different installation methods including Open Cut, Microtunneling, and Horizontal Directional Drilling (HDD). APCTE is one of the engineering firms with the most pipeline South Florida design experience.
Our team is complemented with the following qualified, experience, and well-respected firms who has worked in the past with APCTE in several infrastructure projects:
NADIC ENGINEERING NADIC has assembled a highly qualified and experienced geotechnical professional, technical and administrative staff to work together in order to satisfy the needs of our clients. Each project presents unique opportunities through its location, types of engineering required and economic importance to our clients. To better serve you, we combine our significant academic credentials and engineering expertise in geotechnical, civil, and water resources engineering with other in-house highly qualified professionals from related engineering and sciences. Since it’s founding (September 2001), NADIC has performed over 1,000 projects throughout Florida.
LONGITUDE SURVEYORS AND MAPPERSOne of South Florida’s premier Surveying & Mapping and Underground Utility Locating companies, Longitude’s professional team applies their experience and rigor to provide exceptional results. Whether it involves public infrastructure or private development, our Team provides our Clients, the best possible value and most practical solutions allowing them to achieve their goals. We find our greatest satisfaction in making our clients successful. Longitude was established in 2004, and work closely with municipalities, governing agencies, and private developers to ensure each project’s success. They have provided surveying services for a wide array of projects to include: pump stations, pipeline, roads, public works, school, and parks.
MEDIA RELATIONS GROUP, LLCMRG has extensive experience leading or supporting the public involvement efforts on numerous district-wide and city-wide design-build, design and roadway construction projects at different levels for the Florida Department of Transportation (FDOT) and many other municipalities. Over the past 10 years the firm has led the public involvement efforts for many complex and multi-faceted multi-million-dollar award winning contracts, including the recently completed FDOT District Six State Road (SR) 826/Palmetto Expressway Public Communications Consulting Services (SR 826/836 Interchange Reconstruction Design/Build/Finance) contract. While working on these high-profile contracts MRG has been able to quickly identify the specific demands, meet the needs of the client and the community while providing seamless communications within the project team. As part of their public outreach campaigns, MRG created all content for a project website, developed collateral materials such as construction weekly update reports, press kits, general project description cards, door hangers, newsletters, briefed local elected and appointed officials, conducted several charades, community advisory groups, public meetings and led numerous other community group presentations.
APCTE will commit that the personnel and/or principals named in the proposal shall remain assigned to the project throughout the period of the contract unless provided for otherwise in a negotiated contract. APCTE will not provide any diversion or substitution of personnel or principals without submission of a written request with the qualifications and experience of the proposed replacement to the city for their approval.
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
24
APCTE IS NOT A CERTIFIED MINORITY BUSINESS ENTERPRISE, BUT ALL OF OUR SUBS ARE CERTIFIED SMALL BUSINESS ENTERPRISES WITH MIAMI DADE COUNTY.
The implementation of the Pump Station Rehabilitation Project requires a Project Manager (PM) with proven sanitary sewer system design experience who will deliver this contract on schedule. The Project Manager of our Team will be Mr. Arnelio Alfonso, P.E., who has over 33 years of experience in design of sanitary sewer pump stations and pipelines and has been the Engineer of Record and Project Manager for several sanitary Lift Stations, most of them for the Miami-Dade Water and Sewer Department. As Project Manager, Mr. Alfonso will be responsible for the technical design elements of this project as well as the required coordination of the different disciplines to ensure the timely completion of the project within the proposed schedule. Mr Alfonso’s availability is high for this contract and he will be the single point of contact between APCTE, its sub-consultants, and the City of Sunny Isles Beach. Mr. Alfonso will be supported by top notch professionals who will be responsible for their areas of expertise. One of our design leaders is Mr. Lazaro Ferrero, P.E., a Senior Project Engineer who has over 33 years of experience performing work for Miami-Dade Water and Sewer Department. In addition, we have assembled a team tailored to meet each aspect of this contract. In assembling the staff, we not only looked at the special technical capabilities of the individuals, but also the current and projected workload and availability of each team member. For more information about the organization of our team and the experience of the key team members, see proposal organizational chart and attached resumes.
KNOWLEDGE AND PAST EXPERIENCE OF SIMILAR TYPE OF PROJECTSThe APCTE Team has extensive experience in the design of pumps stations and sanitary sewer conveyance systems. Detailed information about the scope of the most relevant projects completed by our team is included on Section F - Firm Reference and Similar Work Completed of this proposal. Shown below is a summary of the most relevant pump station design projects completed by APCTE as prime consultant and designed and managed by Mr. Alfonso, all of which have been let for construction.• Convention Center Drive Pump Station: includes the design of a 80,000 G.P.M. Stormwater Pump Station. As part of this drainage improvement project, a 96” trunk line was also constructed in this initial phase. The pipe was designed as a collector pipe to receive flows from Collins Avenue and the surrounding streets; this will completed in the near future in the final phase.• Design and rehabilitation of Pump Stations PS 437 and PS 351 for Miami Dade Water and Sewer Department• Crespi Avenue Pump Station: includes a 24,000 G.P.M. stormwater pump station• MIC Pump Station (WASD PS #101): includes 1,020 G.P.M. pumps, 1,580 lf of 12” DIP gravity sewer and 1,400 lf of 12” force main.• Perrine Basin A Pump Station (WASD PS #1142): rated for 793 G.P.M. pumps and includes 6,500 lf of gravity sewer and 3,900 lf of 12” force main.• Perrine Basin B Pump Station (WASD PS #1143): rated for 806 G.P.M. pumps and includes 7,300 lf gravity sewer and 2,500 lf of 12” force main.• Miami Gardens Drive (WASD PS #1320) – rated for 120 G.P.M. pumps and includes 1,400 lf of gravity sewer and 250 lf of force main.• Miami Gardens Drive (CNMB PS #31) – rated for 120 G.P.M. pumps and includes 2,100 lf of gravity sewer and 650 lf of 8” force main.•
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
25
PAST PERFORMANCE OF APCTE TEAM The APCTE Team has a strong reputation in providing its client with construction documents that have, to the highest degree possible, avoided claims, supplemental agreements, and construction delays. The performance by our firm for local agencies and MD WASD over the past 15 years has NOT resulted in a single “unsatisfactory” project performance rating. The APCTE Team is well respected for successfully delivering quality projects on time and within budget exceeding the satisfaction and expectation of Miami-Dade County. Table 1 includes the evaluation/grades that APCTE received from MD-WASD for the Perrine-Cutler Ridge Pump Stations Project. Our company received an average of 3.9 points out of a possible 4.0, which is an excellent score. On another WASD Project E07-WASD-08(A) Reclaimed Water System, APCTE received a perfect score of 4 out of 4. APCTE has provided design services to several Miami-Dade County Departments for a myriad of project within the last fifteen (15) years. During that period, and in connection with those projects, our Principals and Senior Project Managers had the opportunity to interface and interact with several Water and Sewer Department managers from the Administration, Engineering, Contracts, and Utilities Sections. In our dealings with Department representatives, our ultimate goal has always been to meet our client’s needs to the best of our ability. We believe to have succeeded in that commitment.
The proposed project within the Golden Shores community will include an evaluation and rebuilding of the storm drainage pump station, and system hydrologic and hydraulic analysis. This is the City’s only pump station which services the Golden Shores neighborhood and was inherited from the County at the time of incorporation. Since then the City performed one major overhaul that was completed in 2003. This project is planned to assess the performance of the pump station and rebuild the pump station to ensure its continued use. The analysis will be composed of all system drainage, lines, wells, generator, piping and outfalls, backflow prevention devices and check valves, catch basin and the stormwater pump station with a monitoring system.
The APCTE’s Team has extensive experience in all aspects of familiarity with the permitting process, especially in Dade County. Our permit capabilities cover different types of projects that extend from: Stormwater Management Master Plans, Water Distribution Systems, Sanitary Sewer, Force Main and Sanitary Lift Stations, Roadway, Infrastructure, Signalization, Signing and Pavement Marking.
As an example: Infrastructure and Water Resources projects call for several permits from a number of regulatory agencies. This will require in-depth and close coordination between the design team and various agencies, and will involve several activities, which include: agency coordination, permit sketches, permit applications and responding to the RFI letters sent by the agency’s reviewer. During all of these years, we have developed excellent relationships with permitting agencies such as:
• Miami-Dade County Public Works Department (MDCPWD)• Miami-Dade Transit Authority (MDTA)• Miami-Dade Water and Sewer Department (M-D WASD)• Florida Department of Transportation (FDOT)• South Florida Water Management District (SFWMD)• Florida Department of Environmental Protection (FDEP)• U.S. Army Corp of Engineers (USACOE)• Miami-Dade Department of Environmental Resources Management (DERM)
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
26
APCTE has demonstrated its capability of obtaining permits for challenging projects; one example is the Miami Intermodal Center. Below is an in-house checklist of permits that is used as a reference as part of standard procedure in our office:
Permit Type Governmental Agencies
Florida Department of Transportation District
Six (FDOT–VI)
South Florida Water Management District
(SFWMD)
Environmental Protection Agency (EPA)
Miami-Dade Department of Environmental
Resources Management (DERM)
South Florida Water Management District
(SFWMD)
Miami-Dade Department of Transportation
and Public Works
Florida DEP
Miami-Dade Water and Sewer Department
(WASD)
Miami-Dade Transit Authority
Miami-Dade DERM
Miami-Dade Department of Environmental
Resources Management (DERM) Wastewater
Section
Miami-Dade Department of Environmental
Resources Management (DERM) Wastewater
Miami-Dade Fire Department
Florida DEP
Roadway
(Right-of-Way)
Environmental Resources
Permit (ERP)
USEPA General
Construction NPDES Permit
Class II Permit
Right of Way Notice
General Permit
Roadway
(Right-of-Way)
Environmental and
Dewatering
Force Main Extension
Roadway
(Right-of-Way)
Water Main Extension
Utility Permit (FAC 14-46) for Work within FDOT
Right of Way
Stormwater Management Systems (more than
40 Acres)
Construction that disturbs 1 acre or more
Stormwater Management Systems
Work within SFWMD Right of Way
Construction Permit for County Roads
NPDES
Final Review of Force Main
Construction Permit for work within the
Busway Right of Way
Class V (Temporary Dewatering) Permit
Permit to Construct Extension of Public
Sanitary Sewer System
Water Main Extensions
Water Main Extensions
Water Main Extensions
90 days
90 days
90 days
30 days
90 days
30 days
30 days
21 days
90 days
60 days
21 days
15 days
21 days
15 days
Estimated Time to Obtain PermitType of Project / Improvement
Similar Project Experience
The project consists of furnishing all materials, labor, and equipment necessary to upgrade Sewage Pump Station
No. 0351, including, but not limited to, providing uninterrupted by-pass pumping capabilities for the existing pump
station flow during all construction times and until the proposed improvements for the pump station are completely
operational and accepted by the Owner; demolition of existing force mains; refurbishing the existing wet well top slab,
furnish and install new dual 7.5 HP submersible pumps and all associated piping, fittings, equipment, hardware, and
appurtenances for new discharge and emergency connection; furnish and install new control panel, meter can, main
disconnect, motor connection box, new electrical service, power and control conduits and wiring, and the required
concrete slabs and mounting structures; install the RTU enclosure (provided by the Department) and the SCADA
antenna; connection of new electrical service to the pump station. Complete installation of 2700 LF of 8” F.M. along
NW 39 Ave from 175th St to NW 181st St, including the connection to the existing manhole on NW 181st St as
indicated in plans.
A&P Engineers’ team, on behalf of the City of Miami Beach, recently finalized the construction of one of its biggest
stormwater pump stations. This pump has the capacity to move 80,000 gallons per minute (gpm) and is just one of 80
stormwater pump stations the City will construct within the next 8-10 years in order to combat the tidal events and
sea level rise. This design was intended to serve as the prototype for the other pump stations that t he City plans to
construct in the future. In the initial phase of the pump station, trash racks capture solids that are 1” or larger before
the flow reaches the Collins Canal. The remaining flow is split into trains, with a capacity of 40,000 gpm, and is directed
to a water treatment structure and then a wet-well equipped with 2 20,000 gpm axial pumps. The pump station has
been designed with overflow structures for redundancy and to prevent intrusions from tidal events. This project
also saw the construction of a higher seawall, with a minimum top elevation of 5.70’ NAVD, to ensure our design’s
resiliency against future conditions.
CLIENT NAME Miami-Dade Water & Sewer
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION April 2015 - December 2016
CONSULTANT CONTRACT AMOUNT 187,000.00
CLIENT NAME City of Miami Beach
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION May 2016 - May 2018
CONSULTANT CONTRACT AMOUNT 450,000.00
ROLANDO M. ROQUE
(786) 552-8129
roquer@miamidade.gov
LUIS SOTO, P.E.
(305) 673-7000 EXT: 6924
luissoto@miamibeachfl.gov
Rehabilitation of Pump Station 351, Miami, Florida
Stormwater Pump Station at Miami Beach Convention Center
CO
N
T
A
C
T
CO
N
T
A
C
T
KEY PERSONNEL
KEY PERSONNEL
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Similar Project Experience
The Pump Station 0437 is located at 19091 NW 62nd Avenue, Miami, Florida 33015. The project consists of furnishing
all materials, labor, and equipment necessary to upgrade Sewage Pump Station, providing uninterrupted by-pass
pumping capabilities for the existing pump station flow during all construction times and until the new pump station
is completely operational and accepted by the Owner; demolition of existing force mains; partial demolition of the
existing pump station, piping, valve, fittings, ventilation system (supply and exhaust fans), water seal system, etc;
furnish and install new dual 60 HP Yeomans Pumps, fittings, equipment, hardware, and appurtenances for the new
discharge and emergency connection; connection to existing 12-inch force main; furnish and install new control panel,
main disconnect, dry type transformer, power and control conduits and wiring, and the required mounting structures.
Furnish and install disconnect switch, new dry type transformer, electrical panel inside the existing generator room
and a replace the electrical service feeder to the proposed pump station.
The Nautilus Neighborhood includes all of the area from Surprise Lake to the south end of the 41st Street right-of-way,
and from Biscayne Bay east to the Indian Creek waterway, inclusive of the Orchard Park sub-neighbor- hood. The area
is generally comprised of single-family residential streets with some pockets of multi-family uses. Major institutional
uses include Mount Sinai Medical Center, Miami Heart Institute, Nautilus Middle School, and North Beach Elementary
School. Arthur Godfrey Road (41st Street), a State roadway, is a major commercial corridor to the southern border of
this neighborhood. Alton Road is a state minor arterial on the west side. The improvements to the stormwater system
were limited to the three priority drainage basins (92, 97 & 99) identified in the City of Miami Beach Stormwater
Management Master Plan for the Nautilus Neighborhood. Project included milling and resurfacing, new drainage,
including six (6) stormwater pump stations, injection and gravity wells, new water main system betterment, decorative
lighting, signing and pavement marking, landscape and irrigation upgrades, and intersection bump-outs.
CLIENT NAME Miami-Dade Water & Sewer
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION April 2015 - December 2016
CONSULTANT CONTRACT AMOUNT 187,000.00
CLIENT NAME City of Miami Beach
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION February 2007 / August 2008
CONSTRUCTION VALUE $35,000,000
ROLANDO M. ROQUE
(786) 552-8129
roquer@miamidade.gov
Luis Soto, P.E.
(305) 673-7000 Ext: 6924
luissoto@miamibeachfl.gov
Rehabilitation of Pump Station 437, Miami, Florida
Design-Build for Neighborhood No.7 Nautilus Infrastructure Improvements
CO
N
T
A
C
T
CO
N
T
A
C
T
KEY PERSONNEL
KEY PERSONNEL
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Similar Project Experience
This Design Build Project included the Installation of Water Main and
Storm Sewer System along Crespi Blvd between 85TH street and 79TH
Street. The project also includes the installations of over 2500 LF of Water
Main, over 2800 LF of Storm Sewer collection system, Installations of
pollution Control Structure, Installation of (1) Storm Sewer Pump Station,
construction of seawall and landscaping along a residential neighborhood.
This Design-Build Neighborhood Improvement Project included the
installation of over 4000 LF of drainage collection ranging from 18”
to 36” diameter and (1) Storm Water pump station in this residential
neighborhood.
CLIENT NAME City of Miami Beach
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION December 2014 / October 2015
CONSULTANT CONTRACT AMOUNT 345,000.00
CLIENT NAME City of Miami Beach
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION February 2005 / August 2006
CONSTRUCTION VALUE $12,500,000
LUIS SOTO, P.E.
(305) 673-7000 EXT: 6924
luissoto@miamibeachfl.gov
LUIS SOTO, P.E.
(305) 673-7000 EXT: 6924
luissoto@miamibeachfl.gov
Crespi Blvd Pump Station, City of Miami Beach, Florida
Praire Avenue Pump Station, City of Miami Beach, Florida
CO
N
T
A
C
T
CO
N
T
A
C
T
KEY PERSONNEL
KEY PERSONNEL
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
Similar Project Experience
This Design-Build Project included the installation of (2) Storm Water Pump
Stations at the street end of 14th & 10th street along Biscayne Bay. Projects
included the installation of wet well approximately 25’ in depth, drainage
defender box, grate box, valve vault, dissipator box and all miscellaneous
piping. Installation was performed in a tight corridor at the street end of 14th
& 10th Street along Biscayne Bay.
CLIENT NAME City of Miami Beach
LEAD DESIGNER A&P Consulting Transportation Engineers, Corp.
PROJECT DURATION August 2015 / October 2015
CONSTRUCTION VALUE $1,600,000.00
LUIS SOTO, P.E.
(305) 673-7000 EXT: 6924
luissoto@miamibeachfl.gov
Pump Station at 14th & 10th Street, City of Miami Beach, Florida
CO
N
T
A
C
T
KEY PERSONNEL
Arnelio Alfonso, P.E., Lazaro Ferrero, P.E., Angela Baron-Ruiz, P.E., Antonio G. Acosta, PE, C.G.C., Osmany Alfonso, P.E., Adrian Alfonso,E.I.,
Eduardo Martinez, P.E., Alex Guon, P.E.
STANDARD FORM 330
ARCHITECT - ENGINEER QUALIFICATIONS
PART I - CONTRACT-SPECIFIC QUALIFICATIONS
A. CONTRACT INFORMATION
1. TITLE AND LOCATION (City and State)
Consulting Engineering Services for Golden Shores Pump Station Rehabilitation (CCNA)
2. PUBLIC NOTICE DATE
November 5, 2018
3. SOLICITATION OR PROJECT NUMBER
RFQ NO: 18-11-01
B. ARCHITECT-ENGINEER POINT OF CONTACT
4. NAME AND TITLE
Antonio G. Acosta, P.E. - President
5. NAME OF FIRM
A&P Consulting Transportation Engineers, Corp
6. TELEPHONE NUMBER
(305) 592-7283
7. FAX NUMBER
(305) 593-1594
8. E-MAIL ADDRESS
agacosta@apcte.com
C. PROPOSED TEAM
(Complete this section for the prime contractor and all key subcontractors.)
(Check)
9. FIRM NAME 10. ADDRESS 11. ROLE IN THIS CONTRACT
PR
I
M
E
J -V
PA
RT
N
E
R
SU
B
C
O
N
-
TR
A
C
T
O
R
a.
A&P Consulting
Transportation Engineers,
Corp.
10305 NW 41st Street, Suite 115
Doral, Florida 33178
Roadway and Drainage Design,
Traffic and Transportation
Engineering, Planning, Civil Site
Design, Mechanical/Electrical
Design, Contract Administration,
CEI, and Project Management
CHECK IF BRANCH OFFICE
b.
Longitude Surveyors and
Mappers, LLC
7715 NW 48 Street, Suite 310
Doral, Florida 33186
Surveying and Mapping
CHECK IF BRANCH OFFICE
c.
Nadic Engineering Services,
Inc
601 N. Hart Blvd Orlando, FL
32828
Geotechnical
CHECK IF BRANCH OFFICE
d.
Media Relations Group 18001 Old Cutler Rd, Palmetto
Bay, FL 33157
Public Involvement
CHECK IF BRANCH OFFICE
e.
CHECK IF BRANCH OFFICE
f.
CHECK IF BRANCH OFFICE
D. ORGANIZATIONAL CHART OF PROPOSED TEAM (Attached)
PROJECT MANAGER
Arnelio Alfonso, P.E. (A&P)
CITY OF SUNNY ISLES BEACH
QA/QC
Carlos M. Gil-Mera, P.E., C.G.C. (A&P)
PRINCIPAL-IN-CHARGE
Antonio G. Acosta, P.E., C.G.C. (A&P)
PUMP STATION DESIGN GROUP
Arnelio Alfonso, P.E. (A&P)Julian Gomez, E.I. (A&P)Roberto Lazamares, P.E. (A&P)Tania Fernandez (A&P)
DRAINAGE DESING GROUP
Lazaro Ferrero, P.E. (A&P)Angela M. Baron-Ruiz, P.E. (A&P)Magali Alfonso (A&P)Vivian Martinez (A&P)
STRUCTURAL GROUP
Osmany Alfonso, P.E. (A&P)Adrian Alfonso, E.I. (A&P)Nairobis Perez Villalobos (A&P)Jose Rodriguez (A&P)
MECHANICAL/ELECTRICAL
Eduardo Martinez, P.E. (A&P)Alex Guon, P.E. (A&P)Leonardo Sempe (A&P)Ricardo Batista (A&P)
S U P P O R T S E R V I C E S
SURVEY
Eduardo M. Suarez, P.S.M. (LON)John Adler, P.S.M. (LON)Azahel Echevarria Gonzalez (LON)Daniel Ferrera (LON)
GEOTECHNICAL
Godwin Nnadi, Ph.D., P.E (NES)Brandon Johnson, E.I. (NES)Mustafa Syed, E.I. (NES)
ENVIRONMENTAL PERMIT
Angela M. Baron-Ruiz, P.E (A&P)Ariel Marquez, E.I. (A&P)
NAME PUMPSTATION DRAI-NAGEDESIGN
ENVIRON-MENTALPERMITS
YEARSOFEXPER.Arnelio Alfonso, P.E. (A&P)x 33Antonio G. Acosta, P.E., C.G.C. (A&P)x x 32Carlos M. Gil-Mera, P.E., C.G.C. (A&P)x x 32Julian Gomez, E.I. (A&P)x x x 1Roberto Lazamares, P.E. (A&P) x x 9Tania Fernandez (A&P)x x x 17Lazaro Ferrero, P.E. (A&P)x 33Angela M. Baron-Ruiz, P.E. (A&P)x x 10Magali Alfonso (A&P)x 31Vivian Martinez (A&P)x x 32Osmany Alfonso, P.E. (A&P)x x 23Adrian Alfonso, E.I. (A&P)x x 4Nairobis Perez Villalobos (A&P)x x 5Jose Rodriguez (A&P)x 42Eduardo Martinez, P.E. (A&P)x 39Alex Guon, P.E. (A&P)x 28Leonardo Sempe (A&P)x 39Ricardo Batista (A&P)x 3Nelson Perez, P.E, C.G.C (A&P)x x 42Erik Sibila, P.E., C.G.C. (A&P)x x 10Alexander Milz, P.E. (A&P)x x 6Phillip Garcia, P.E. (A&P)x x 7Eduardo M. Suarez, P.S.M. (LON)x 33John Adler, P.S.M. (LON)x 34Azahel Echevarria Gonzalez (LON)x 15Daniel Ferrera (LON)x 15Godwin Nnadi, Ph.D., P.E (NES)x x 38Brandon Johnson, E.I. (NES)x x 4Mustafa Syed, E.I. (NES)x 10Ariel Marquez, E.I. (A&P)x x 0
CONSTRUCTION MANAGEMENT
Nelson Perez, P.E, C.G.C (A&P) Erik Sibila, P.E., C.G.C. (A&P)Alexander Milz, P.E. (A&P)Phillip Garcia, P.E. (A&P)Jorge Abela (A&P)
CITY OF SUNNY ISLES BEACH | REQUEST FOR QUALIFICATIONS NO. 18-11-01
CONSULTING ENGINEERING SERVICES FOR GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
EXPERIENCEABREV.COMPANY(A&P)A&P Consulting Transportation Engineers, Corp.(LON)Longitude Surveyors, LLC(NES)Nadic Engineering Services, Inc.(MRG)Media Relations Group, LLC
Organizational Chart
A&P Consulting Transportation Engineers, Corp.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Antonio G. Acosta, P.E., C.G.C. 13. ROLE IN THIS CONTRACT Principal-in-Charge 14. YEARS EXPERIENCE
a. TOTAL 31 b. WITH CURRENT FIRM 17
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelors of Science – Civil Engineering
Florida International University, Miami, Florida
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No. 40845
• Fl. Certified General Contractor No. C.G.C.47411
• Florida Certified Air Conditioning Contractor No.
CAC057593
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Center (MIC), Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) 2010
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Roadways and Infrastructure Task Manager for the MIC Management Group. In charge of the development of Drainage and Utility Master Plan
for the 1.3 billion dollar projects. Also in charge of coordinating all the development of all the Roadway Plans, including Geotechnical, Survey,
Right of Way. Responsible for coordination with all different agencies having projects in the area like MDX, Miami Dade County Public Works,
City of Miami, Miami International Airport etc.
b.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from US-1 to SW 8th Street
Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2007
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the milling & resurfacing of a 2.5 mi segment of this urban corridor. Including upgrading ten signalized
intersections from span-wire to mast-arm, implementation of a traffic safety study, compliance with ADA requirements, signing & pavement
markings, decorative lighting, and the design of a new 12" water main as part of a JPA between FDOT and M-D WASD, which included the
installation of approximately 3,150 L.F. of 12" D.I.P, 210 L.F. of 16” D.I.P., 1430 L.F. of 8” D.I.P. with fire hydrants, connections, and stub-outs.
c.
(1) TITLE AND LOCATION (City and State) SR-997 / Krome Avenue US-1 to Avocado Drive / SW 296th Street,
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2006 CONSTRUCTION (If applicable) 2014
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
This portion of Krome Avenue is a north-south two-lane roadway that extends approximately 3.78 miles from US-1 to Avocado Drive, running
through the center of Florida City and the City of Homestead in southern Miami-Dade County. Mr. Acosta prepared Construction Documents
(plans and specifications) for the 3.78 mile segment of this urban corridor, including signing & pavement markings, upgrading seven signalized
intersections from span-wire to mast-arm, a new signalized intersection, 0.5 mi of lighting, implementation of four traffic safety studies,
implementation of Access Management and compliance with ADA requirements, Landscaping, & Irrigation within the City of Homestead, Fl.
d.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from SW 8th Street to NW
11th Street, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2008
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the milling & resurfacing of a 1.2 mi segment of this urban corridor. Including upgrading two signalized
intersections from span-wire to mast-arm, implementation of a traffic safety study, compliance with ADA requirements, signing & pavement
markings, and the design of a new 12" water main as part of a JPA between FDOT and M-D WASD, which included the installation of
approximately 4,306 L.F. of 12" D.I.P., 60 L.F. of 8" D.I.P., and 440 L.F. of 6" D.I.P. with fire hydrants, connections, & stub-outs.
e.
(1) TITLE AND LOCATION (City and State) S.W. 62nd Avenue from SW 24th Street to NW 7th Street, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) 2013
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the total reconstruction of a 2.0 mi segment of this urban corridor. Including upgrading one signalized
intersections from span-wire to mast-arm, implementation of a traffic safety study, compliance with ADA requirements, drainage design,
signing & pavement markings, and the design of a new street lighting system.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Arnelio Alfonso, P.E. 13. ROLE IN THIS CONTRACT Project Manager 14. YEARS EXPERIENCE
a. TOTAL 32 b. WITH CURRENT FIRM 17
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science in Civil Engineering, IPSJAE
Havana, Cuba, 1985
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No. 52566
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
• Hydrology Course 1988 University of Madrid,Spain
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Nautilus Neighborhood Streetscape Improvements Design-Built
Project, Miami Beach, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) 2010
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer of Record and Project Manager for this design/build project. Responsibilities included the design of water main distribution mains,
storm water injection wells system with pump stations, streetscape improvements, road milling and resurfacing, street lighting design, signing
and markings and signalization design.
b.
(1) TITLE AND LOCATION (City and State)
Washington Avenue Design-Built Project – Phase 2, 4 and 5, Miami
Beach, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2006 CONSTRUCTION (If applicable) 2006
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer of Record and Project Manager for this design/build project. Responsibilities included the design of water main distribution mains,
sanitary sewer pipe/manhole up sizing, storm water gravity wells system, new curb/gutter and sidewalk, road milling and resurfacing, street
lighting design, signing and markings and signalization design.
c.
(1) TITLE AND LOCATION (City and State) NW 14th Street Reconstruction, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2002 CONSTRUCTION (If applicable) 2004
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer of Record and Project Manager for the total reconstruction of NW 14th Street from NW 42nd Court to NW 34th Avenue. This project
included the preparation of Roadway Plans, Drainage improvements including a Pump Station, Signalization, Lighting, Signing & Pavement
Markings, and Intelligent Transportation System (I.T.S) Plans.
d.
(1) TITLE AND LOCATION (City and State) SR-804 / Boynton Beach Blvd., 3R Project and Minor Bridge Widening,
Palm Beach County, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2007
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer of Record for the Milling & Resurfacing of Boynton Beach Blvd. from Old Boynton Beach to US-1. This project included the preparation
of Roadway Plans for Milling & Resurfacing, Minor Bridge Plans, Signalization and Signing Marking Plans
e.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Center (MIC), Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2004 CONSTRUCTION (If applicable) 2006
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Responsible for the development of the Utility Master Plan for the MIC Program as well as the preparation of Utility Relocation Schedules,
Reimbursable Agreements with utility companies, Utility Clear Packages and Utility Design by FDOT Consultant Agreements (JPA’s) for all the
MIC Roadway Projects.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Lazaro. Ferrero, P.E. 13. ROLE IN THIS CONTRACT Stormwater / Permitting 14. YEARS EXPERIENCE
a. TOTAL 32 b. WITH CURRENT FIRM 14
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science - Civil Engineering, 1985.
Polytechnic University of Havana Cuba
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No. 58025
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Districtwide Traffic Safety Studies, FDOT District 4, Broward County
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Project Manager and Sr. Traffic Engineer on this contract which includes a wide range of traffic safety studies such as pedestrian safety
studies, fatal crash reviews and Road Safety Audits (RSAs). This contract includes 16 hours per week of in-house support services at the
Engineer Intern level at the District Four offices.
b.
(1) TITLE AND LOCATION (City and State) Districtwide Pedestrian and Bicycle Safety Studies, FDOT, District Six,
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Project Manager and Sr. Traffic Engineer on this contract. The focus of this contract is the investigation of citizen’s requests related to
pedestrian and bicycle safety and mobility. This contract includes a full time Engineer Intern at the District Six offices performing studies and
field investigation and also developing work orders for maintenance to implement signing and pavement marking improvements such as the
implementation of high emphasis crosswalks and “Turning Vehicle Yield To Pedestrians” signs.
c.
(1) TITLE AND LOCATION (City and State) SR 90/SW 8th Street from SW 142nd Avenue to SW 67th Avenue,
FDOT, District Six
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable)
N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The scope of this project includes the implementation of the first Adaptive Signal Control Technology project (ASCT) in Miami-Dade County at
29 signalized intersections along SR 90/SW 8th Street. Mr. Espino is responsible for the inventory and inspection of the existing signal cabinets,
controllers, conduits and pull boxes to determine the need for equipment upgrade as part of the project. He is also responsible for the travel
time data collection using Wifi devices as part of the before and after evaluation phase of the pilot project. Mr. Espino has performed
extensive coordination with the Miami-Dade County Traffic Control Center to ensure a smooth transition from existing signal operation to
operation under ASCT.
d.
(1) TITLE AND LOCATION (City and State) SR 5/US 1 from SW 19500 Block to I-95 Signal Re-timing and
Monitoring, FDOT, District Six
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
This project is part of the Districtwide Signal Retiming Contract with the D6 Traffic Operations Office. The tasks included daily monitoring of
traffic conditions from using CCTV cameras at the D6 Sunguide Transportation Management Center. Monitoring was with the objective of the
monitoring was to identify operational deficiencies and areas of recurrent congestion and to develop and implement signal timing changes to
improve these conditions. The monitoring also included using Regional Integrated Transportation Information System (RITIS) data to monitor
operational performance before and after the implementation of the signal timing changes.
e.
(1) TITLE AND LOCATION (City and State) Districtwide Traffic Operations and Safety Studies Contract (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2013 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
A task work order driven contract which included the investigation of fatal crashes and high crash locations district-wide. As part of this
contract Mr. Espino completed over 850 fatal crash reviews to determine roadway contributory causes. Mr. Espino also performed safety
studies districtwide and developed safety improvement projects at over fifty intersections and segments.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Angela Baron, P.E. 13. ROLE IN THIS CONTRACT Stormwater / Permitting 14. YEARS EXPERIENCE
a. TOTAL 10 b. WITH CURRENT FIRM 6
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelors of Science in Civil Engineering, Fall 2008
Florida International University, Miami, FL.
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No.76984
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Districtwide Traffic Safety Studies, FDOT, District Four
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Sr. Traffic Engineer on this contract which includes a wide range of traffic safety studies such as pedestrian safety studies, fatal
crash reviews and Road Safety Audits (RSAs). Mr. Castillo has recently completed the following safety studies: (1) RSA at SR
5/US 1 at Barber Street, City of Sebastian in Indian River County, (2) Monitor and assess implementation of pedestrian recall
phase at the intersection of SR A1A at SR 842/Las Olas Blvd. (3) SR 5/N. Federal Highway at NE 1st Street, Delray Beach,
perform signal warrant analysis and sight distance evaluation.
b.
(1) TITLE AND LOCATION (City and State) Advanced Transportation Management System (ATMS) - Phase 1
Design-Build Criteria Package, Districtwide Minor Design Contract, St.
Lucie County, FL, FDOT, District Four
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Project Manager and Engineer-of-Record for the development of a design-build criteria package for the design, construction, and
integration of St. Lucie County's ATMS Phase-1 project. St. Lucie County’s ATMS Phase-1 project consists of installing a fiber-
optic communications network for 56 signalized intersections, installing and integrating the ATMS software, and installing and
integrating 17 closed-circuit television (CCTV) cameras. These intelligent transportation systems (ITS) subsystems will be
connected to a transportation management center (TMC) at the FDOT’s Treasure Coast Operations Center, which will be designed
and built under ATMS Phase 1.
c.
(1) TITLE AND LOCATION (City and State) S.R. 5/U.S. 1 Adaptive Signal Control Technology (ASCT), Districtwide
Minor Design Contract Fort Pierce, FL, FDOT, District Four
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Project Manager and Engineer-of-Record for the preparation of Plans, Specifications and Estimates (PS&E) package for the
implementation of an ASCT Project on a S.R. 5/U.S. 1 segment (Section No. 94010000) at 12 intersections located within the City
of Fort Pierce, St. Lucie County, Florida. Tasks have included the coordination of workshops with vendors from two ASCT
technologies, performing an inventory of existing conditions of the signal controllers and video detection system. The project has a
production date of January 2017.
d.
(1) TITLE AND LOCATION (City and State) SR 90/SW 8th Street from SW 142nd Avenue to SW 67th Avenue,
Adaptive Signal Control Technology (ASCT), District Six
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The scope of this project includes the implementation of the first Adaptive Signal Control Technology project (ASCT) in Miami-
Dade County at 29 signalized intersections along SR 90/SW 8th Street. Mr. Castillo has provided a wide range of support as part of
this contract such as development of the RFP documents, bench testing of signal and ASCT hardware as part of the integration of
the Insync adaptive signal system with D170 traffic controllers. He is currently supporting the monitoring of signal operations during
project “burning” period before final project acceptance.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Tania Fernandez 13. ROLE IN THIS CONTRACT Project Engineer 14. YEARS EXPERIENCE
a. TOTAL 17 b. WITH CURRENT FIRM 11
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science in Civil Engineering, IPJAE Havana,
Cuba
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State)
In-House Consultant for Traffic Operations for the Florida Department
of Transportation
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Ms. Borges assists the Department with their workload. Her responsibilities include performing engineering reviews, analyzing
recommendations in traffic engineering reports, using Synchro to perform operational analysis, preparing necessary associated documents
(work orders, traffic regulations, sign designs, etc.), performing field assessments to identify operational and safety deficiencies, and obtaining
and analyzing crash data. In addition, she currently oversees and review several pedestrian and bicyclist studies. Her duties also include
representing the Department in meetings and presentations, and coordination with the public and other government agencies.
b.
(1) TITLE AND LOCATION (City and State) City of Miami River Greenway Streetscape Project, City of Miami,
Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) 2010
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The project begins on SW 1st Court and extends through SW 6th Street for a total of 0.379 miles until the S. Miami Ave. overpass. The scope
of work is to enhance the roadway and community through the reconstruction of SW 6th Street, milling and resurfacing of the surrounding
streets, new drainage structures, new sidewalks and curb and gutter, new driveways, improved hardscape, ADA compliant ramps and parking,
new pavement markings, updated signage, lush landscaping on proposed islands and swale, and decorative lighting.
c.
(1) TITLE AND LOCATION (City and State) Traffic Operations Analyst for the Florida Department of
Transportation
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable)
N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
duties included performing engineering reviews, analyzing and developing traffic engineering reports and associated documents (work orders,
traffic regulations, traffic studies, sign designs, etc.), and performing field assessments to identify operational and safety deficiencies. Ms.
Borges also participated in meetings and presentations, coordinated with Department staff and affected external agencies and customers, and
allocated the necessary resources to implement remedial action. Additionally, she developed and managed professional and contractual
service contracts that supported traffic operations, issued task work orders, reviewed contract deliverables and processed invoices,
coordinated Department personnel and other agencies associated with work under the contract.
d.
(1) TITLE AND LOCATION (City and State) SR 7/NW 7th Avenue at NW 14th Street, NW 17th Street, NW 23rd
Street, and NW 29th Street Signalization Upgrades
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) 03
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Safety intersection improvements project which consisted of the installation of protected/permissive left-turn traffic signal heads on the North
and South approaches at the above mentioned signalized intersections. Project also included parking prohibition regulation on the west side
of NW 7th Avenue and NW 29th Street, and the reconstruction of pedestrian ADA ramps and sidewalks.
e.
(1) TITLE AND LOCATION (City and State) ARRA Project Miami Lakeway North Resurfacing and Drainage
Improvements, Town of Miami Lakes, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) 2011
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
This was a FDOT ARRA Funded Project in North Shore for City of Miami Beach Public Works. The project consisted of roadway improvements
for Byron Avenue, including milling & resurfacing, new signing and pavement markings, and new safety improvements such as ADA ramps and
sidewalks.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Osmany Alfonso, P.E. 13. ROLE IN THIS CONTRACT Senior Structural Project Engineer 14. YEARS EXPERIENCE
a. TOTAL 22 b. WITH CURRENT FIRM 5
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science – Civil Engineering December
1995, Florida International University, Miami, Florida
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No. 61601
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Districtwide Pedestrian and Bicycle Support, FDOT, District 6
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Ms. Diaz provided services as a Senior Traffic Engineering Analyst and leads the performance of traffic engineering studies to investigate the
need for pedestrian and bicycle safety improvements districtwide..
b.
(1) TITLE AND LOCATION (City and State) Pedestrian Safety and Mobility Evaluation along SR 90/SW 8th
Street/SW 7th Street from SR 9/SW 27th Avenue to SR 5/Brickell
Avenue, Miami FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The scope of services for this study included extensive pedestrian counts and documentation of existing conditions including land uses, transit
ridership and pedestrian and bicycle crash data. The 3-mile study segment was divided into homogeneous sections based on land use and
pedestrian activity for analysis. The study also included plotting pedestrian and bicycle crashes to identify crash clusters and assessing the
need for mid-block pedestrian crossings using the guidelines contained in the Traffic Engineering Manual (TEM). The study recommendations
included overhead Rectangular Rapid Flashing Beacons (RRFBs) at several locations.
c.
(1) TITLE AND LOCATION (City and State) Districtwide Planning & Environmental Management Services, FDOT,
District Six
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2012 CONSTRUCTION (If applicable)
N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Task work order driven contract which includes traffic data collection, general planning, corridor/project planning, preliminary design and
engineering, project development and environmental, traffic operations analysis, interchange analysis reports, systems planning, travel
demand forecasting, and public involvement. Ms. Diaz served as the lead engineer for the pedestrian and bicycle safety study on SR
5/Biscayne Boulevard from NE 55th Terrace to NE 77th Street
d.
(1) TITLE AND LOCATION (City and State) Districtwide Traffic Operations/Safety Studies Contract, FDOT, District
Six
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As DPM, Ms. Diaz was responsible for reviewing all types of study tasks outlined in the Scope of Services for this contract, e.g., Qualitative
Assessment, Signal Warrant Analysis, Intersection Analysis, Left Turn Phase Warrant Analysis, and Speed Zone Studies. Through this contract,
Ms. Diaz performed skid hazard location investigations consistent with the objective of the Highway Safety Improvement Program. Ms. Diaz
investigated and reported possible slippery pavement sections in Miami Dade and Monroe Counties. Ms. Diaz was responsible for reviewing
the data stored in the FDOT Skid Hazard Reporting System, identifying highway sections with a friction number in questionable or review
categories, and updating the System documenting all activities, e.g., review of crash summaries, geometrics, surface condition, posted speed,
recent projects, etc., related to the highway sections investigated
e.
(1) TITLE AND LOCATION (City and State) Districtwide Pushbutton Minor Design Contract, FDOT, District Six (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2006 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As DPM for this work order driven contract, Ms. Diaz was responsible for reviewing roadway, signing/pavement markings, signal design plans,
and construction cost estimates for the implementation of traffic safety and operational improvements, e.g., school zone, audible pedestrian
signal, and traffic signal installation. Ms. Diaz was responsible for the administration of two Minor Design Pushbutton Contracts & overseeing
all activities related to the production of design plans at the 90% and 100% phase levels in conformance with FDOT Standards
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Adrian Alfonso, E.I. 13. ROLE IN THIS CONTRACT Structural Designer 14. YEARS EXPERIENCE
a. TOTAL 4 b. WITH CURRENT FIRM 4
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science in Mechanical Engineering, 2014
Florida, International University, Miami, Florida
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Engineer Intern No.1100019341
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) District Wide Signal Re-Timing Contract
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Responsible for evaluating state roadways during peak traffic periods, to develop signal timing recommendations to improve traffic
progression throughout the designated Miami-Dade County Traffic Signals and Signs (TS&S) Sections along the study segment.
Responsibilities included coordinating with Miami-Dade County TS&S Signal Zone Engineer
b.
(1) TITLE AND LOCATION (City and State) US 1 Signal Operations and Monitoring, Miami-Dade County, FL (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As part of the signal retiming efforts, Ms. Poe is currently monitoring US 1 from SW 16th Avenue to SW 19500 Block and providing
recommendations for signal timing fine tuning of cycle lengths, offsets, and phase splits. This effort includes constant
communication and coordination with the Miami-Dade County Signal Zone Engineer; as well as meeting with FDOT and other
County officials on a regular basis. This effort is being conducted to try and improve the coordination between signals especially
for corridor sections with bottleneck intersections, heavy peak period congestion, and heavy pedestrian activity.
c.
(1) TITLE AND LOCATION (City and State) SR 924/Gratigny Parkway Speed Evaluation, MDX, Miami-Dade County,
FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2014 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer responsible for evaluating the posted speed limits along SR 924 from the interchange with SR 826/Palmetto Expressway
to 1,300 feet west of NW 32 Avenue. The analysis included field reviews, prevailing speed characteristics (as obtained from MDX
ITS detectors), crash review, and a geometric design review of all elements that pertain to speed, to recommend the change or
maintenance of the existing posted speed limits along the corridor.
d.
(1) TITLE AND LOCATION (City and State) Safety Initiatives – Pilot Project Locations Assessment, MDX, Miami-
Dade County, FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2014 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Engineer responsible for researching, documenting, and evaluating pavement marking technologies as countermeasures/or safety
improvements to existing MDX roadway segments exhibiting unsafe or improvable operations (i.e. wrong-way drivers, excessive
speeds, roadway geometry, and construction/transition zones). The study included drafting a technical memorandum with potential
pilot project sites for varying pavement marking products, as well as drafting a presentation to the MDX Board of Directors
e.
(1) TITLE AND LOCATION (City and State) City of Stuart Intersection Operations Study, Martin County, FL (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2014 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Ms. Poe was responsible for analyzing and documenting the existing conditions for a network of 7 intersections in the City of Stuart, FL (Martin
County). The analysis included field reviews, level-of-service analysis through modeling, and a travel time and delay analysis; in order identify
needs and leverage results to help prioritize projects
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Eduardo Martinez, P.E. 13. ROLE IN THIS CONTRACT Senior Electrical, Lighting And Its
Engineer
14. YEARS EXPERIENCE
a. TOTAL 39 b. WITH CURRENT FIRM 13
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Bachelor of Science Civil Engineering, 1979 Polytechnic
University of Havana, Havana, Cuba
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Professional Engineer No. 52023
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Districtwide Traffic Operations Push Button Contract, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The purpose of this Contract is to implement and design improvements related to safety and operational, usually requested by public and
elected officials. These assignments are typically of quick turn-around (2 weeks to design) and fast response (2 weeks to construct) nature.
The following is partial list of pedestrian and bicycle studies completed in City of Coral Gables and other local municipalities as part of this
contract.
b.
(1) TITLE AND LOCATION (City and State) Districtwide Miscellaneous PE Design Consultant, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2017 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
This Contract includes a variety of design assignments, including RRR Project, Safety and Operational projects. The following is partial list of
design projects completed within the City of Coral Gables and other municipalities as part of this contract: SR-5 / US-1 / South Dixie Highway
at Grand Avenue; SR-5 / US-1 / South Dixie Highway from Santona Street to East of Granada Blvd; SR-5 / US-1 / South Dixie Highway from SR-
94 / Kendall Drive to SW 80th Street / Davis Road.
c.
(1) TITLE AND LOCATION (City and State) Miscellaneous Design Consultant, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The purpose of this Contract is to provide design services to the CIPT to address residents complaint related to safety, operational, and
drainage issues. The following is a list of the relevant projects: Flagami Traffic Calming Improvements; Coral Gate Community Improvements;
Miami River Greenway SW 1st Court to South Miami Avenue
d.
(1) TITLE AND LOCATION (City and State) Miami Performing Arts Center Streetscape Improvements, City of
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2006
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Designer of record to Prepare Construction Documents (plans and specifications) for the reconstruction of SR-5 / Biscayne Boulevard for NE
13th Street, NE 14th Street, NE 15th Street, NE 2nd Avenue and N. Bayshore Drive. Project included preparation of contract documents including
milling and resurfacing, upgrading existing sidewalks to artistic pavers, new decorative lighting, signing and pavement markings and landscape.
e.
(1) TITLE AND LOCATION (City and State) Neighborhood 10-B Flamingo Streetscape Improvements, City of
Miami Beach, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) 2015
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Senior Project Manager responsible for the Design-Build Project of 7th, 8th Street (from Meridian Avenue to Pennsylvania Avenue), Meridian
Ave, Euclid Ave, and Pennsylvania Ave (from 7th to 9th Street). Project includes reconstruction of roadway, sidewalk, ADA compliance, safety
improvements, signing, pavement markings, new drainage, water main upgrades, and lighting. Responsible for obtaining all local permits and
utility coordination.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Alex Guon, P.E. 13. ROLE IN THIS CONTRACT Senior Electrical, Lighting And Its
Engineer
14. YEARS EXPERIENCE
a. TOTAL 27 b. WITH CURRENT FIRM 13
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• University of Havana, Higher Polytechnic, Institute,
School of Engineering and Architecture Cuba, 1990
• Licensed Electrical Engineer, ISPJAE, University of
Havana, Cuba (1990).
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Professional Electrical Engineer - Florida
No.53247
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Center (MIC), Miami Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) 2010
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Roadways and Infrastructure Task Manager for the MIC Management Group. In charge of the development of Drainage and Utility Master Plan
for the 1.3 billion dollar projects. Also in charge of coordinating all the development of all the Roadway Plans, including Geotechnical, Survey,
Right of Way. Responsible for coordination with all different agencies having projects in the area like MDX, Miami Dade County Public Works,
City of Miami, Miami International Airport etc.
b.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from US-1 to SW 8th Street
Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2007
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the milling & resurfacing of a 2.5 mi segment of this urban corridor. Including upgrading ten signalized
intersections from span-wire to mast-arm, implementation of a traffic safety study, compliance with ADA requirements, signing & pavement
markings, decorative lighting, and the design of a new 12" water main as part of a JPA between FDOT and M-D WASD, which included the
installation of approximately 3,150 L.F. of 12" D.I.P, 210 L.F. of 16” D.I.P., 1430 L.F. of 8” D.I.P. with fire hydrants, connections, and stub-outs.
c.
(1) TITLE AND LOCATION (City and State) SR-997 / Krome Avenue US-1 to Avocado Drive / SW 296th Street,
Miami-Dade County, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2006 CONSTRUCTION (If applicable) 2014
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
This portion of Krome Avenue is a north-south two-lane roadway that extends approximately 3.78 miles from US-1 to Avocado Drive, running
through the center of Florida City and the City of Homestead in southern Miami-Dade County. Mr. Acosta prepared Construction Documents
(plans and specifications) for the 3.78 mile segment of this urban corridor, including signing & pavement markings, upgrading seven signalized
intersections from span-wire to mast-arm, a new signalized intersection, 0.5 mi of lighting, implementation of four traffic safety studies,
implementation of Access Management and compliance with ADA requirements, Landscaping, & Irrigation within the City of Homestead, Fl.
d.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from SW 8th Street to NW
11th Street, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2005 CONSTRUCTION (If applicable) 2008
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the milling & resurfacing of a 1.2 mi segment of this urban corridor. Including upgrading two signalized
intersections from span-wire to mast-arm, implementation of a traffic safety study, compliance with ADA requirements, signing & pavement
markings, and the design of a new 12" water main as part of a JPA between FDOT and M-D WASD, which included the installation of
approximately 4,306 L.F. of 12" D.I.P., 60 L.F. of 8" D.I.P., and 440 L.F. of 6" D.I.P. with fire hydrants, connections & stub-outs.
e.
(1) TITLE AND LOCATION (City and State) S.W. 62nd Avenue from SW 24th Street to NW 7th Street, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) 2013
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Prepare a Contract Plans Set for the total reconstruction of a 2.0 mi segment of this urban corridor. Including upgrading one signalized
intersections from span-wire to mast-arm, implementation of four traffic calming devices (traffic circles), compliance with ADA requirements,
new drainage system including pump station design, signing & pavement markings, design of a new decorative street lighting system, and
landscape design.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Erik Sibila, P.E., M.S.C.E., C.G.C. 13. ROLE IN THIS CONTRACT Senior Pm / Project Administrator 14. YEARS EXPERIENCE
a. TOTAL 14 b. WITH CURRENT FIRM 11
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Master of Science Civil Engineering, 2011 FL,
International University Miami, FL
• Bachelor of Science Civil Engineering, 2008
Architectural Engineering, 2008, Summa Cum Laude
University of Miami, Coral Gables, Florida
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• 2012, FL P.E. No.74663
• 2004, FL General Contractor CGC1508340
• 2013, FL Surveyor-in-Training
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Center (MIC); Water and Sewer Improvements &
Drainage Master Plan, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES February 2003 CONSTRUCTION (If applicable) December 2005
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Water Resources Project Manager, was responsible for preparing the Water and Sewer Improvement Program. This project included
coordination with MD-WASD and all utility companies present in the area in order to design a master water and sewer system which included
the design of a new regional lift station (PS 101), a gravity sewer system, 12" force main and 24" water main that will provide services to the
future Rental Car Center and a 30" steel casing installed by microtunneling under the CSX RR. As well as the Development a Stormwater
Management Master Plan for a total area of 742 Acres.
b.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from US-1 to SW 8th Street
Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES March 2005 CONSTRUCTION (If applicable) October 2007
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Water Resources Project Manager, Mr. Alfonso was responsible for design of a 12" Water Main Plans as part of a JPA between FDOT and
M-D WASD, which included the installation of approximately 3,150 L.F. of 12" D.I.P, 210 L.F. of 16” D.I.P., 1430 L.F. of 8” D.I.P. with fire
hydrants, connections, and stub-outs. Project also included the upgrade of the drainage system.
c.
(1) TITLE AND LOCATION (City and State) NW 37 Avenue/Transit Access Road; 24" Force Main, Miami, FLorida (2) YEAR COMPLETED
PROFESSIONAL SERVICES December 2004 CONSTRUCTION (If applicable) September 2005
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Project Manager, Mr. Alfonso was responsible for design of a 24" Force main along the Transit Access Road from NW 25 ST to NW 28 ST.
The project included 2000 LF of a 24" force main that serves the City of Miami Springs; the existing meter P-10 was relocated as part of this
project, as well as the design of the French Drain System.
d.
(1) TITLE AND LOCATION (City and State) NE 103 ST / SR 932; 16" Water Main, Miami, FL.
(2) YEAR COMPLETED
PROFESSIONAL SERVICES May 2004 CONSTRUCTION (If applicable) June 2006
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Project Manager, Mr. Alfonso was responsible for design of a 16" Water Main along NE 103 ST from NW 7 Avenue to NE 6 Avenue. The
project included 8000 LF of a 16" water main, the installation of 143 water service lines with the corresponding water meters and 18 new fire
hydrants
e.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from SW 8th Street to NW
11th Street, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES July 2005 CONSTRUCTION (If applicable) January 2008
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Water Resources Project Manager, Mr. Alfonso was responsible for design of a 12" Water Main Plans as part of a JPA between FDOT and
M-D WASD, which included the installation of approximately 4,306 L.F. of 12" D.I.P., 60 L.F. of 8" D.I.P., and 440 L.F. of 6" D.I.P. with fire
hydrants, connections, and stub-outs. Project also included the upgrade of the drainage system.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Phillip Garcia, E.I. 13. ROLE IN THIS CONTRACT Senior Inspector 14. YEARS EXPERIENCE
a. TOTAL 5 b. WITH CURRENT FIRM 5
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• University of Florida - Gainesville, Florida, Awarded
Bachelor of Science in Civil Engineering, December
2011.
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Florida Engineer Intern No.1100018392
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) NW 25 ST, 36" Force Main, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES May 2005 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As the Project Engineer, Mr. Ferrero assisted in the design of a 36" Force main along NW 25th Street from NW 89 Avenue to SR-826 (Palmetto
Expressway). The project included a crossing of a DERM Canal through a 54" steel casing
b.
(1) TITLE AND LOCATION (City and State) SR 953 / NW 42 Ave, 12" Water Main, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES March 2005 CONSTRUCTION (If applicable) May 2007
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Project Engineer, Mr. Ferrero assisted in the design of a 12" Water Main Plans as part of a JPA between FDOT and M-D WASD, which
included the installation of approximately 3,150 L.F. of 12" D.I.P, 210 L.F. of 16” D.I.P., 1430 L.F. of 8” D.I.P. with 12 fire hydrants, 500 LF of
service lines, and stub-outs. Project also included the upgrade of the drainage system
c.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Rental Car Center (RCC), Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES November 2008 CONSTRUCTION (If applicable) July 2010
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Project Engineer for the site civil plans, which included paving, grading and drainage, domestic and fire water mains and the sanitary system
design, following the MDWASD and FDOT drainage manual requirements. The total area of the project is 30 Acres
d.
(1) TITLE AND LOCATION (City and State) Miami Intermodal Center (MIC), FDOT District 6, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES February 2003 CONSTRUCTION (If applicable) December 2005
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Development a Stormwater Management Master Plan. This is multimodal transportation facility, which link Metrorail, Amtrak, Tri-Rail, High
Speed Train and Metrobus. The total area of the project is 742 Acres, which includes the SR 836/SR 112 Interconnector, MIC Core, Rental Car
Facilities, MIC/MIA Connector and Baggage Tunnel.
e.
(1) TITLE AND LOCATION (City and State) SR-953 / S.W. 42nd Avenue / Le Jeune Road, from SW 8th Street to NW
11th Street, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES July 2005 CONSTRUCTION (If applicable) January 2008
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
As Project Engineer, Mr. Ferrero assisted in the design of a 12" Water Main Plans as part of a JPA between FDOT and M-D WASD, which
included the installation of approximately 4,306 L.F. of 12" D.I.P., 60 L.F. of 8" D.I.P., and 440 L.F. of 6" D.I.P. with fire hydrants, connections,
and stub-outs. Project also included the upgrade of the drainage system.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Jorge Abela 13. ROLE IN THIS CONTRACT Inspector 14. YEARS EXPERIENCE
a. TOTAL 29 b. WITH CURRENT FIRM 8
15. FIRM NAME AND LOCATION (City and State) A&P Consulting Transportation Engineers, Corp., Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Undergraduate Civil Engineering Course Work (3 years)
Florida International University
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• TIN No. A140432631660
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.) Final Estimate Level I Advance MOT, ETQP Concrete Specifications
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) MIC-Earlington Heights Connector, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES May 2010 CONSTRUCTION (If applicable) On-Going
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Mr. Martinez is the Electrical Engineer of Record for this project. The project included the design for the required duct banks to provide 750
VDC connection between each traction power sub-stations and the contact rails for the positive feeders and running rails for the negative
feeders, design of the guideway grounding and lighting protection systems, which included three 13.2KV/750 VDC sub-stations with two
5MVA rectifier/transformer units feeding a 10 KADC switch gear. Our electrical department, as part of the design team, has been involved in
monthly coordination meetings with MDX Agency representatives, architects/engineers and system consultants. For this project our company
has already submitted the 90% set of construction plans
b.
(1) TITLE AND LOCATION (City and State) D/B SR-826 / SR-836 Interchange Electrical Design, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES On-Going CONSTRUCTION (If applicable) On-Going
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The project consisted of several levels of ramps providing proper connections between both expressways. This required a new lighting system
for SR-826, from S.W. 4th Street to N.W. 22nd Street, and for SR-836, from N.W. 92nd Avenue to East of N.W. 72nd Avenue. Due to the
construction of new on and off ramps, additional lighting was installed on impacted side streets including, but not limited to, Flagler Street and
87th Avenue. The new lighting system consisted of approximately one thousand lighting poles along both highways and more than one
hundred under bridge deck luminaires, mounting heights between fifteen and forty-five feet. The entire lighting system required seven
service points with an average of 200 amps each, and it was designed to comply with FDOT and MDX criteria. Special conditions and
considerations were given to design the section of SR-826 in the vicinity of Miami International Airport to comply with Federal Aviation
Authority regulations
c.
(1) TITLE AND LOCATION (City and State) South Dade Waste Water Treatment Plant (SDWWTP), Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES February 2007 CONSTRUCTION (If applicable) On-Going
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
The Miami-Dade South District Wastewater Treatment Plant (SDWWTP) is undergoing improvements. This project includes detailed electrical
design services to assist the Department with Consent Order compliance for a new 285 mgd HLD facility. APCT is responsible for the following
upgrades: Onsite Sodium Hypochlorite Generation Facility (OSHG), new filter system and transfer pump station. APCT also provided technical
information for the permitting process relevant to the electrical discipline of the OSHG Facility and new filter system and transfer pump
station. Mr. Guon participated in several design workshops and assisted in value engineering.
d.
(1) TITLE AND LOCATION (City and State) Miami Performing Arts Center Streetscape Improvements, City of
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES December 2005 CONSTRUCTION (If applicable) October 2006
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Designer of record to Prepare Construction Documents (plans and specifications) for the reconstruction of SR-5 / Biscayne Boulevard for NE
13th Street, NE 14th Street, NE 15th Street, NE 2nd Avenue and N. Bayshore Drive. Project included preparation of contract documents including
milling and resurfacing, upgrading existing sidewalks to artistic pavers, new decorative lighting, signing and pavement markings and landscape.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Eduardo M. Suarez, PSM 13. ROLE IN THIS CONTRACT Principal in Charge 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) Longitude Surveyors LLC
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Associate in Science in Engineering Studies, Miami-
Dade College, Miami, Florida 1993
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• Professional Surveyor and Mapper, State of
Florida LS6313
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State)
Pump Station 0435, Aventura, FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2015 CONSTRUCTION (If applicable) 2015
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
LS performed a Topographic Survey to include the following information: LS set control points, easement lines, points of
intersections and bearings basis. LS provided horizontal and vertical location of visible fixed objects within project limits including
electrical cabinet, meters, telemetry antenna, pump station control cabinet, transformer, hose bib cabinet location and perimeter
fence with entrance gate. Longitude included bottom elevations for cabinets/panels, height and top elevation for transformer
concrete pad. LS located trees with 3-inch diameter trunks or larger, fire hydrants, valves, water meters, gas, street lighting, power
and telecommunication poles and/or cabinets. LS collected rim, top and invert elevations of all existing sanitary sewers’ manholes,
pump wet and dry wells, sanitary sewer lines, drainage culverts, manholes and catch basins and grate elevations, diameter of the
wet/dry well and valve vault dimensions. Located project site perimeter, driveway and station service/staging area, and corners
including finished grade low and high points with elevations.
b.
(1) TITLE AND LOCATION (City and State) Pump Station 1056, 19749 Bel Aire Drive, Cutler Bay, FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) 2016
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
LS performed a Map Boundary and Topographic Survey to include the following information: determined dimensions, elevations
and measurements of existing pump station features and piping. LS determined the site layout, and obtained site specific
information. Longitude collected the following information: such as right of way lines, subdivision lines, lot lines, base lines and
easement line. Performed six (6) Subsurface Utility Exploration vacuum excavations to determine location, depth, size and material
of underground utilities that are in potential conflict.
c.
(1) TITLE AND LOCATION (City and State) Pump Station 0114, 680 NW 97th Avenue, Miami, FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2015 CONSTRUCTION (If applicable) 2015
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
LS performed a Topographic Survey to include the following information: horizontal and vertical location of visible fixed
improvements within project limits including: electrical cabinet, meters, telemetry antenna, pump station control cabinet,
transformer, hose bib cabinet location and perimeter fence with entrance gate. LS collected bottom elevations for cabinets/panels,
height/top elevation for transformer concrete pad. LS located trees with 3-inch diameter trunks or larger, location of
hedges/flowering beds, fire hydrants, valves, water meters, gas, street lighting, power and telecommunication poles and/or
cabinets within twenty feet of the station site boundary. LS collected spot elevations at approximately 100-foot intervals. Immediate
pavement markings & signage on the adjacent street fronting the pump station site. LS collected rim, top and invert elevations of all
existing sanitary sewers’ manholes, pump wet/dry wells, sanitary sewer lines, drainage culverts, manholes and catch basins, grate
elevations, diameter of the wet/dry well and valve vault dimensions.
d.
(1) TITLE AND LOCATION (City and State) Pump Station 0860, Miami, FL
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2015
CONSTRUCTION (If applicable) 2016
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
LS performed Subsurface Utility Engineering to include the following information: designated twenty-four (24) areas where there
were conflicting lines using an Electromagnetic Locator and Ground Penetrating Radar (GPR). LS provided elevations at surface
and measure down will be made to the top of pipe. LS determined the size, type of material, & provided the dimensions of the
encasement and provided field work sheets for each pot hole.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Godwin Nnadi, Ph.D., P.E. 13. ROLE IN THIS CONTRACT - 14. YEARS EXPERIENCE
a. TOTAL 38 b. WITH CURRENT FIRM -
15. FIRM NAME AND LOCATION (City and State) Nadic Engineering Services, inc.
16. EDUCATION (DEGREE AND SPECIALIZATION)
• Ph.D. Civil Engineering (1990) Queens University,
Kingston, Canada
• M.S. Civil Engineering (1980); Purdue University,
Lafayette, Indiana
• B.S Mining/Geological Eng., (1979); University of
Nevada, Reno
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• PE No.50637, Florida 1996
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Design-Build Services For The Installation Of 4.5 Miles Of New 54-Inch
Diameter Forcemain And The Rehabilitation Of 2.5 Miles Of Existing
54-Inch Diameter Forcemain, Miami-Dade County, Fl.
(2) YEAR COMPLETED
PROFESSIONAL SERVICES - CONSTRUCTION (If applicable) -
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
MDWASD identified plans to rehabilitate the existing 54-inch diameter South District Force Main from southern Miami-Dade
County, City of Homestead, and Florida City to SDWWTP, and install a redundant 54-inch bypass FM to allow for the sustainable
conveyance of wastewater flows from the South District service areas to SDWWTP.
NADIC conducted a series of 20-foot deep SPT borings along the existing 54-inch FM alignment and 35-foot deep SPT borings
and rock corings along the proposed Bypass/Redundancy FM alignment. Dr. Nnadi provided both Geotechnical Data Report and
Geotechnical Design Memorandum.
b.
(1) TITLE AND LOCATION (City and State) Design Build 48-Inch Diameter Pccp Force Main Along Nw 2nd Ave,
Nw 11th St, N. Miami Ave., & Ne 36th St., Miami-Dade County.
(2) YEAR COMPLETED
PROFESSIONAL SERVICES - CONSTRUCTION (If applicable) -
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
MDWASD awarded the design, installation and commission of the 13,000 LF of 48-inch diameter prestressed concrete cylinder
pipe (PCCP) force main (FM), 5600 LF of 12-inch diameter WM and 1000 LF of 24-inch stormwater drainage pipe to David Mancini
& Sons, Inc. Dr Nnadi is the geotechnical engineer of record. NADIC conducted geotechnical investigation; performed Phase II
environmental assessment and is performing the construction materials testing. Installation methods consist of open-cut and jack &
bore methods.
c.
(1) TITLE AND LOCATION (City and State)
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
d.
(1) TITLE AND LOCATION (City and State)
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME Mustafa Syed 13. ROLE IN THIS CONTRACT - 14. YEARS EXPERIENCE
a. TOTAL 11 b. WITH CURRENT FIRM -
15. FIRM NAME AND LOCATION (City and State) Nadic Engineering Services, inc.
16. EDUCATION (DEGREE AND SPECIALIZATION)
• B.S Civil Engineering, 2006, Osmania University, India
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
ACI Concrete Field Testing- Grade 1
FDOT Concrete Field Technician Level 1
FDOT Earthwork Construction Inspector–Level 1
FDOT Asphalt Paving Level 1 & 2
FDOT Asphalt Plant Level 1
Nuclear Gauge Safety & U.S.D.O.T Hazmat
Intermediate MOT
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) PSIP Design Services For Pump Stations, Miami-Dade County (2) YEAR COMPLETED
PROFESSIONAL SERVICES - CONSTRUCTION (If applicable) -
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Miami-Dade Water and Sewer Department (MDWASD) MDWASD has established a Pump Station Improvement Program (PSIP)
for upgrading the Wastewater Collection and Transmission System (WCTS) that includes pump stations and force mains pursuant
to which each pump station has to be certified as capable of meeting a Nominal Average Pump Operating Time (NAPOT) of less
than or equal to 10 hours per day. Mr. Syed conducted the required geotechnical evaluations and recommendations.
b.
(1) TITLE AND LOCATION (City and State) 30-Inch D.I.P Force Main In Sw 3 Avenue From Sw 15 Road To Sw 11
Street
(2) YEAR COMPLETED
PROFESSIONAL SERVICES - CONSTRUCTION (If applicable) -
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
NADIC was retained by MDWASD to conduct geotechnical engineering investigation for installation of 30-inch Ductile Iron Pipe
(D.I.P.) Force Main Installation along SW 3rd Avenue in Miami. Mr. Syed assisted as the project engineer on geotechnical
engineering investigation.
c.
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
d.
(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME x 13. ROLE IN THIS CONTRACT x 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) PlusUrbia Design, Inc., Miami, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• x
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• x
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
x
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Little Havana Revitalization, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Exclusive local planning studio for partnership with the National Trust for Historic Preservation that will preserve the authenticity of
Little Havana while providing policy recommendations for proper growth and development of a residential neighborhood in walking
distance of Downtown Miami. Revitalization plan includes design for healthy living, complete streets and multimodal transportation.
b.
(1) TITLE AND LOCATION (City and State) Wynwood Neighborhood Revitalization District, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Crafted a national model for urban zoning codes to support creative industries, mixed-use, transit-supportive development, proper
urban scale and green space. Created policies for preservation, affordable housing, centralized parking and complete streets.
c.
(1) TITLE AND LOCATION (City and State) Hialeah Transit Oriented Development Districts, Hialeah, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Master plan and land-use policy for Transit Oriented Development (TOD) around the city’s Market District and Transfer rail
stations. Supports compact, mixed-use development around advantageous rail connectivity. Creates affordable housing with rail
connectivity to job centers throughout the County and region..
d.
(1) TITLE AND LOCATION (City and State) Hialeah Complete Streets Plan, Hialeah, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
A Complete Streets plan was created to ensure that rail transit in two TODs is connected to wide sidewalks, safe street crossings,
bike lanes and public transit. Guidelines can be applied citywide to ensure dense, mixed-use districts will be served by multimodal
mobility..
e.
(1) TITLE AND LOCATION (City and State) Calle 8 Revitalization, Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
PlusUrbia, with strong ties to Miami’s Southwest 8th Street, or Calle Ocho, initiated this proposal to restore the corridor as a
walkable, pedestrian-oriented main street for Little Havana. The firm has created images of a 21st century Calle Ocho with
multimodal transportation alternatives such as dedicated bike and transit lanes, comfortable wide sidewalks and additional safe
crosswalks in a vibrant urban setting.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME x 13. ROLE IN THIS CONTRACT x 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) x
16. EDUCATION (DEGREE AND SPECIALIZATION)
• x
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• x
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
APA National Economic Development Plan Award, Dade Heritage Trust Annual Preservation Award Little Havana National Treasure,
Miami-Dade MPO Transportation Aesthetics Review Committee, Dade Heritage Trust Board Member
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Little Havana Revitalization, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Exclusive local planning studio for partnership with the National Trust for Historic Preservation that will preserve the authenticity of
Little Havana while providing policy recommendations for proper growth and development of a residential neighborhood in walking
distance of Downtown Miami. Revitalization plan includes design for healthy living, complete streets and multimodal transportation.
b.
(1) TITLE AND LOCATION (City and State) Village of El Portal Form-Based Code, El Portal, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Creation of new municipal zoning ordinance and companion Comprehensive Plan amendments. Recommendations focus on mixed-
use Town Center and corridor legislation that will generate new economic sources and provide a destination for the Village in close
proximity to a planned future transit station.
c.
(1) TITLE AND LOCATION (City and State) North Ponce Mixed-Use Overlay District, Coral Gables, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Authored Comprehensive Plan and Zoning Code Text and Map Amendments for the North Ponce de Leon Boulevard trolley corridor.
Regulations included Transfer of Development Rights program updates, adjustments to maximum density and FAR, and building
massing and step back provisions to protect residential neighborhood from large-scale mixed-use projects along Ponce de Leon
Boulevard.
d.
(1) TITLE AND LOCATION (City and State) U.S. 1/Red/Sunset Corridor Visioning Workshop, Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES
CONSTRUCTION (If applicable)
N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Organized and directed a two-day session featuring broad stakeholder input on the future character of development along the US1
corridor, including management of traffic generated by US1 and ways of protecting residential areas from intensive commercial
development. Key topics included strategies to improve pedestrian character, quality and connectivity of public space, streets and
planning to make the Underline an integral part of the city. Transit-Oriented Development -- to reduce traffic and make car-free
mobility an option for area residents and University of Miami students, faculty and staff -- was explored.
e.
(1) TITLE AND LOCATION (City and State) Downtown Overlay, Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Drafted form-based zoning regulations to enhance the pedestrian character of Downtown Coral Gables and to encourage beautiful,
economically sustainable, and controlled development. The overlay will provide incentives for small and medium-scale
development, to encourage sustainable, controlled growth, small business development, an active residential population, and
beautiful streets and public spaces. The Overlay was developed through community input and close collaboration with the
Business Improvement District of Coral Gables.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME x 13. ROLE IN THIS CONTRACT x 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) X
16. EDUCATION (DEGREE AND SPECIALIZATION)
• x
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• x
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
APA National Economic Development Plan Award, Dade Heritage Trust Annual Preservation Award Little Havana National Treasure,
APA Florida 2016 Award of Excellence Wynwood Neighborhood Revitalization, 10th Annual KINPAN Award-China, Miami Herald,
Miami FL Character of Little Havana, Op-Ed, FitCity Miami 3/American Institute of Architects, Florida APA Annual Conference
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Little Havana Revitalization, Miami, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES
CONSTRUCTION (If applicable)
N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Exclusive local planning studio for partnership with the National Trust for Historic Preservation that will preserve the authenticity of
Little Havana while providing policy recommendations for proper growth and development of a residential neighborhood in walking
distance of Downtown Miami. Revitalization plan includes design for healthy living, complete streets and multimodal transportation.
b.
(1) TITLE AND LOCATION (City and State) Hialeah Complete Streets Plan, Hialeah, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
A Complete Streets plan was created to ensure that rail transit in two TODs is connected to wide sidewalks, safe street crossings,
bike lanes and public transit. Guidelines can be applied citywide to ensure dense, mixed-use districts will be served by multimodal
mobility.
c.
(1) TITLE AND LOCATION (City and State) Hialeah Transit Oriented Development Districts, Hialeah, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2016 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Master plan and land-use policy for Transit Oriented Development (TOD) around the city’s Market District and Transfer rail
stations. Supports compact, mixed-use development around advantageous rail connectivity. Creates affordable housing with rail
connectivity to job centers throughout the County and region.
d.
(1) TITLE AND LOCATION (City and State) Lujiao Antler Town, Chongging, China
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Chongqing Antler Town is designed to set new benchmarks in senior living and sustainability, while harmoniously integrating the
surrounding landscape and built form. Located in the vicinity of Chongqing’s City Center, the site is served by several metro
trains and buses that connect it to the rest of the region. The advantage of mass transit is fully integrated into the design..
e.
(1) TITLE AND LOCATION (City and State) Village of El Portal Form-Based Code, El Portal, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Creation of new municipal zoning ordinance. Recommendations focus on a mixed-use Town Center and corridor legislation that
will generate new economic sources and provide a destination for the Village. PlusUrbia translated the vision created by the Village
during its 2013 Charrette into a visual, user friendly and easy to review document known as a form-based code.
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME x 13. ROLE IN THIS CONTRACT x 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) Longitude Surveyors LLC, Doral, Florida
16. EDUCATION (DEGREE AND SPECIALIZATION)
• x
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• x
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Ponce de Leon Median Installation and Roadway Improvements
(Phase II), Ponce de Leon Blvd from Alcazar Ave to Sidonia Ave., City
of Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Performed surveying and mapping services; Curb and Gutter Median Stakeout, West Side Curb and Gutter Stakeout, East Side
Curb and Gutter Stakeout, Mast Arm Stakeout for the Salamanca Intx, and Final As-Built Survey.
b.
(1) TITLE AND LOCATION (City and State) City of Miramar Improvements, Miramar, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Perform and Prepare a Topographic Survey along various streets in the City of Miramar over 75,000 +/- linear feet was surveyed.
Project Manager
c.
(1) TITLE AND LOCATION (City and State) E07-WASD-07A Design of Distribution of Pipeline for Reclaimed Water
System from Central District Wastewater Treatment Plant to Key
Biscayne (5 miles) including the Bear Cut Channel Survey, Miami.
Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Survey-Topographic Survey, Showed all improvements from Right-of-Way to Right-of-Way, Establishing Horizontal and Vertical
Control for future construction, Cross Sections (spot elevations), All utility information provided, Tree Descriptions.
d.
(1) TITLE AND LOCATION (City and State) City of Miami Glenroyal Corridor Drainage Improvements, City of
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Topographic Survey, established Vertical and Horizontal control for future construction, all utility information provided, cross
sections (spot elevations, tree information, all improvements shown from Right-of-Way to Right-of-Way.
e.
(1) TITLE AND LOCATION (City and State) FDOT District VI, Collins Ave. (State Road A-1-A) from Lincoln Road to
26 Street, City of Miami Beach, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
1.25 miles of Topographic Survey / Show all improvements from Right-of-Way to Right-of-Way / Establishing Horizontal and
Vertical Control for future construction / Cross sections (spot elevations).
STANDARD FORM 330
E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
(Complete one Section E for each key person.)
12. NAME x 13. ROLE IN THIS CONTRACT x 14. YEARS EXPERIENCE
a. TOTAL x b. WITH CURRENT FIRM x
15. FIRM NAME AND LOCATION (City and State) x
16. EDUCATION (DEGREE AND SPECIALIZATION)
• x
17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE)
• x
18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
19. RELEVANT PROJECTS
a.
(1) TITLE AND LOCATION (City and State) Ponce de Leon Median Installation and Roadway Improvements
(Phase II), Ponce de Leon Blvd from Alcazar Ave to Sidonia Ave., City
of Coral Gables, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2011 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Performed surveying and mapping services; Curb and Gutter Median Stakeout, West Side Curb and Gutter Stakeout, East Side
Curb and Gutter Stakeout, Mast Arm Stakeout for the Salamanca Intx, and Final As-Built Survey.
b.
(1) TITLE AND LOCATION (City and State) City of Miramar Improvements, Miramar, Florida (2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Perform and Prepare a Topographic Survey along various streets in the City of Miramar over 75,000 +/- linear feet was surveyed.
Project Manager
c.
(1) TITLE AND LOCATION (City and State) E07-WASD-07A Design of Distribution of Pipeline for Reclaimed Water
System from Central District Wastewater Treatment Plant to Key
Biscayne (5 miles) including the Bear Cut Channel Survey, Miami.
Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Survey-Topographic Survey, Showed all improvements from Right-of-Way to Right-of-Way, Establishing Horizontal and Vertical
Control for future construction, Cross Sections (spot elevations), All utility information provided, Tree Descriptions.
d.
(1) TITLE AND LOCATION (City and State) City of Miami Glenroyal Corridor Drainage Improvements, City of
Miami, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2009 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
Topographic Survey, established Vertical and Horizontal control for future construction, all utility information provided, cross
sections (spot elevations, tree information, all improvements shown from Right-of-Way to Right-of-Way.
e.
(1) TITLE AND LOCATION (City and State) FDOT District VI, Collins Ave. (State Road A-1-A) from Lincoln Road to
26 Street, City of Miami Beach, Florida
(2) YEAR COMPLETED
PROFESSIONAL SERVICES 2010 CONSTRUCTION (If applicable) N/A
(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm
1.25 miles of Topographic Survey / Show all improvements from Right-of-Way to Right-of-Way / Establishing Horizontal and
Vertical Control for future construction / Cross sections (spot elevations).
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
1
21. TITLE AND LOCATION (City and State)
Rehabilitation of Pump Station 351, Miami, Florida
22. YEAR COMPLETED
PROFESSIONAL SERVICES
December 2016
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
Miami-Dade Water & Sewer
b. POINT OF CONTACT NAME
Rolando M. Roque, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(786) 552-8129
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
The project consists of furnishing all materials, labor, and equipment necessary
to upgrade Sewage Pump Station No. 0351, including, but not limited to,
providing uninterrupted by-pass pumping capabilities for the existing pump
station flow during all construction times and until the proposed improvements
for the pump station are completely operational and accepted by the Owner;
demolition of existing force mains; demolition of the existing pump station
including, but not limited to the following: refurbishing the existing wet well top
slab, surrounding fence, instrumentation and control panels, pumps, piping,
valves, fittings, hardware, appurtenances, conduits, and all other items deemed
necessary to be removed for the successful installation of the new pump station
equipment; site preparation of project area as necessary; furnish and install new
gravity and force mains along with associated connections; furnish and install
new dual 7.5 HP submersible pumps and all associated piping, fittings,
equipment, hardware, and appurtenances for new discharge and emergency
connection; connection to existing 8-inch force main; furnish and install new
control panel, meter can, main disconnect, motor connection box, new electrical
service, power and control conduits and wiring, and the required concrete slabs
and mounting structures; install the RTU enclosure (provided by the
Department) and the SCADA antenna; connection of new electrical service to
the pump station; site restoration; installing new chain link fence and gate; start
up and testing of pump station; and other appurtenant and miscellaneous items
and work for a complete, satisfactory and functional installation. Complete installation of 2700 LF of 8” F.M. along NW
39 Ave from 175th St to NW 181st St, including the connection to the existing manhole on NW 181st St as indicated in
plans.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
2
21. TITLE AND LOCATION (City and State)
Stormwater Pump Station at Miami Beach Convention Center
22. YEAR COMPLETED
PROFESSIONAL SERVICES
On-going
CONSTRUCTION (If applicable) -
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER City of Miami Beach b. POINT OF CONTACT NAME
Luis Soto, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER (305) 673-7000 Ext: 6924
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
A&P Engineers team, on behalf of the City of Miami Beach,
recently finalized the construction of one of its biggest
stormwater pump stations. This pump has the capacity to
move 80,000 gallons per minute (gpm) and is just one of 80
stormwater pump stations the City will construct within the
next 8-10 years in order to combat the tidal events and sea
level rise.
As part of this drainage improvement project, a 96” trunk
line was also constructed in this initial phase. The pipe was
designed as a collector pipe to receive flows from Collins
Avenue and the surrounding streets; this will completed in
the near future in the final phase.
This design was intended to serve as the prototype for the
other pump stations that the City plans to construct in the
future. In the initial phase of the pump station, trash racks
capture solids that are 1” or larger before the flow reaches
the Collins Canal. The remaining flow is split into trains, with
a capacity of 40,000 gpm, and is directed to a water
treatment structure and then a wet-well equipped with 2
20,000 gpm axial pumps. The pump station has been
designed with overflow structures for redundancy and to
prevent intrusions from tidal events. This project also saw the construction of a higher seawall, with a minimum top
elevation of 5.70’ NAVD, to ensure our design’s resiliency against future conditions.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
3
21. TITLE AND LOCATION (City and State) Rehabilitation of Pump Station 437, Miami, Florida
22. YEAR COMPLETED
PROFESSIONAL SERVICES December, 2016
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
Miami-Dade Water & Sewer
b. POINT OF CONTACT NAME
Rolando M. Roque, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(786) 552-8129
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
The Pump Station 0437 is located at 19091 NW 62nd Avenue, Miami,
Florida 33015; in Section 01, Township 52, Range 40, Miami-Dade County,
Florida. The project consists of furnishing all materials, labor, and
equipment necessary to upgrade Sewage Pump Station No. 0437,
including, but not limited to, providing uninterrupted by-pass pumping
capabilities for the existing pump station flow during all construction
times and until the new pump station is completely operational and
accepted by the Owner; demolition of existing force mains; partial
demolition of the existing pump station including, but not limited to the
following: the existing instrumentation and control panels, pumps, piping,
valves, fittings, hardware, appurtenances, conduits, and all other items
inside dry well deemed necessary to be removed for the successful
installation of the new pumps, piping, valve, fittings, ventilation system
(supply and exhaust fans), water seal system, etc as indicated in plans;
site preparation and clearing and grubbing of project area as necessary;
furnish and install new force mains along with associated connections;
furnish and install new dual 60 HP Yeomans Pumps or approved equal and
all associated piping, fittings, equipment, hardware, and appurtenances
for the new discharge and emergency connection; connection to existing
12-inch force main; furnish and install new control panel, main
disconnect, dry type transformer, power and control conduits and wiring,
and the required mounting structures. Furnish and install disconnect
switch, new dry type transformer, electrical panel inside the existing
generator room and a replace the electrical service feeder to the
proposed pump station; site restoration; start up and testing of pump station; and other appurtenant and miscellaneous
items and work for a complete, satisfactory and functional installation. Existing generator and fuel tank with all their
appurtenant will remain.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
4
21. TITLE AND LOCATION (City and State)
Design-Build for Neighbornhood No.7 Nautilus Infrastructure
Improvements
22. YEAR COMPLETED
PROFESSIONAL SERVICES 2008
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER City of Miami Beach b. POINT OF CONTACT NAME
Luis Soto, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER (305) 673-7000 Ext: 6924
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
The Nautilus Neighborhood includes all of the area
from Surprise Lake to the south end of the 41st Street
right-of-way, and from Biscayne Bay east to the Indian
Creek waterway, inclusive of the Orchard Park sub-
neighbor- hood. The area is generally comprised of
single-family residential streets with some pockets of
multi-family uses. Major institutional uses include
Mount Sinai Medical Center, Miami Heart Institute,
Nautilus Middle School, and North Beach Elementary
School.
Arthur Godfrey Road (41st Street), a State roadway, is
a major commercial corridor to the southern border of
this neighborhood. Alton Road is a state minor arterial
on the west side. The improvements to the stormwater system were limited to the three priority drainage basins (92, 97
& 99) identified in the City of Miami Beach Stormwater Management Master Plan for the Nautilus Neighborhood.
Project included milling and resurfacing, new drainage, including six (6) stormwater pump stations, injection and gravity
wells, new water main system betterment, decorative lighting, signing and pavement marking, landscape and irrigation
upgrades, and intersection bump-outs.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
5
21. TITLE AND LOCATION (City and State)
Crespi Blvd Pump Station, City of Miami Beach, Florida
22. YEAR COMPLETED
PROFESSIONAL SERVICES
October, 2015
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER City of Miami Beach b. POINT OF CONTACT NAME
Luis Soto, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 673-7000 Ext: 6924
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
This Design Build Project included the Installation of Water Main and
Storm Sewer System along Crespi Blvd between 85TH street and 79TH
Street. The project also includes the installations of over 2500 LF of
Water Main, over 2800 LF of Storm Sewer collection system,
Installations of pollution Control Structure, Installation of (1) Storm
Sewer Pump Station, construction of seawall and landscaping along a
residential neighborhood.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
6
21. TITLE AND LOCATION (City and State)
Praire Avenue Pump Station, City of Miami Beach, Florida
22. YEAR COMPLETED
PROFESSIONAL SERVICES
2006
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
City of Miami Beach
b. POINT OF CONTACT NAME
Luis Soto, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 673-7000 Ext: 6924
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
This Design-Build Neighborhood Improvement Project
included the installation of over 4000 LF of drainage
collection ranging from 18” to 36” diameter and (1) Storm
Water pump station in this residential neighborhood.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
7
21. TITLE AND LOCATION (City and State)
Pump Station at 14th & 10th Street, City of Miami Beach, Florida
22. YEAR COMPLETED
PROFESSIONAL SERVICES
2015
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
City of Miami Beach
b. POINT OF CONTACT NAME
Luis Soto, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 673-7000 Ext: 6924
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
This Design-Build Project included the installation of (2) Storm
Water Pump Stations at the street end of 14th & 10th street along
Biscayne Bay. Projects included the installation of wet well
approximately 25’ in depth, drainage defender box, grate box, valve
vault, dissipator box and all miscellaneous piping. Installation was
performed in a tight corridor at the street end of 14th & 10th Street
along Biscayne Bay.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
8
21. TITLE AND LOCATION (City and State)
Mt. Sinai Pump Station, Miami Beach, FL
22. YEAR COMPLETED
PROFESSIONAL SERVICES
2016
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
Pro Service Group, Llc
b. POINT OF CONTACT NAME
Julio Amoedo
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 989-8044
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
LS prepared and performed a Topographic Survey. Longitude established right-of-way lines, subdivision lines, section
lines, lot lines, base lines and easement lines as required by the project. LS established line data from the right-of-way
maps and MDWASD and utility easement records. Set points of curvature and points of tangency in the field. All
improvements were shown from Right of Way to Right of Way. Longitude established location of trees, rim, top and
invert elevations of all existing sanitary sewers’ manholes, pump wet and dry wells, sanitary sewer lines, drainage
culverts, manholes and catch basins and grate elevations, diameter of the wet/dry well and valve vault dimensions.
Location of project site perimeter, driveway and station service/staging area corners (including finished grade low and
high points) with elevations.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
Longitude Surveyors, LLC
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Surveying and Mapping
b. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
9
21. TITLE AND LOCATION (City and State)
Pump Station 0860, Miami, FL
22. YEAR COMPLETED
PROFESSIONAL SERVICES
2016
CONSTRUCTION (If applicable)
2016
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
MDWASD
b. POINT OF CONTACT NAME
Arnelio Alfonso
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 592-7283
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
LS performed Subsurface Utility Engineering to include the following information: designated twenty-four (24) areas
where there were conflicting lines using an Electromagnetic Locator and Ground Penetrating Radar (GPR). LS provided
elevations at surface and measure down will be made to the top of pipe. LS determined the size, type of material, &
provided thedimensions of the encasement and provided field work sheets for each pot hole.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng.
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b. (1) FIRM NAME
Longitude Surveyors, LLC
(2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Surveying and Mapping
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
f. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S
QUALIFICATIONS FOR THIS CONTRACT
(Present as many projects as requested by the agency, or 10 projects, if not specified.
Complete one Section F for each project.)
20. EXAMPLE PROJECT KEY
NUMBER
10
21. TITLE AND LOCATION (City and State)
PSIP Design Services for Pump Stations
22. YEAR COMPLETED
PROFESSIONAL SERVICES
-
CONSTRUCTION (If applicable)
-
23. PROJECT OWNER'S INFORMATION
a. PROJECT OWNER
MDWASD
b. POINT OF CONTACT NAME
Arnelio Alfonso, P.E.
c. POINT OF CONTACT TELEPHONE NUMBER
(305) 592-7283
24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost)
MDWASD has established a Pump Station Improvement Program (PSIP) for upgrading the Wastewater Collection and
Transmission System (WCTS) that includes pump stations and force mains pursuant to which each pump station has to
be certified as capable of meeting a Nominal Average Pump Operating Time (NAPOT) of less than or equal to 10 hours
per day. NADIC is retained by APCTE to conduct the required geotechnical services.
25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT
a. (1) FIRM NAME
A&P Consulting Transportation Eng. (2) FIRM LOCATION (City and State)
Doral, Florida
(3) ROLE
Prime / Civil Engineering
b.
(1) FIRM NAME
Nadic Engineering Services, Inc.
(Nadic)
(2) FIRM LOCATION (City and State)
601 N. Hart Blv Orlando, FL 32828
(3) ROLE
Geotechnical
c. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
d. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
e. (1) FIRM NAME
(2) FIRM LOCATION (City and State)
(3) ROLE
STANDARD FORM 330
G. KEY PERSONNEL PARTICIPATION IN EXAMPLE PROJECTS
26. NAMES OF KEY
PERSONNEL
(From Section E,
Block 12)
27. ROLE IN THIS
CONTRACT
(From Section E,
Block 13)
28. EXAMPLE PROJECTS LISTED IN SECTION F
(Fill in "Example Projects Key" section below before completing
table. Place "X" under project key number for
participation in same or similar role.)
1 2 3 4 5 6 7 8 9 10
Arnelio Alfonso, P.E. Project Manager
Antonio G. Acosta, P.E.,
C.G.C. Principal in Charge
Lazaro Ferrero, P.E. Stormwater / Permitting
Angela Baron, P.E. Stormwater / Permitting
Tania Fernandez Project Engineer
Osmany Alfonso, P.E. Senior Structural Project
Engineer
Adrian Alfonso, E.I. Structural Designer
Eduardo Martinez, P.E. Senior Electrical Lighting and
ITS Engineer
Alex Guon, P.E. Senior Electrical Lighting and
ITS Engineer
Erik Sibila, P.E., M.S.C.E.,
C.G.C.
Senior PM / Project
Administrator
Phillip Garcia, E.I. Senior Inspector
Jorge Abela Inspector
Eduardo M. Suarez, PSM Principal in Charge
Godwin Nnadi, Ph.D., PE.
Mustafa Syed
29. EXAMPLE PROJECTS KEY
NO. TITLE OF EXAMPLE PROJECT (FROM SECTION F) NO. TITLE OF EXAMPLE PROJECT (FROM SECTION F)
1 Rehabilitation of Pump Station 351,
Miami, Florida 6 Praire Avenue Pump Station, City of
Miami Beach, Florida
2 Stormwater Pump Station at Miami
Beach Convention Center 7 Pump Station at 14th & 10th Street,
City of Miami Beach, Florida
3 Rehabilitation of Pump Station 437,
Miami, Florida 8 Mt. Sinai Pump Station, Miami Beach, Florida
4 Design-Build for Neighbornhood No.7
Nautilus Infrastructure Improvements 9 Pump Station 0860, Miami, FL
5 Crespi Blvd Pump Station, City of Miami
Beach, Florida 10 PSIP Design Services for Pump Stations
H. ADDITIONAL INFORMATION (continued)
STANDARD FORM 330
30. PROVIDE ANY ADDITIONAL INFORMATION REQUESTED BY THE AGENCY. ATTACH ADDITIONAL SHEETS AS NEEDED.
A&P was incorporated in the State of Florida in January 1995 as an “S” Corporation FEID # 65-0770583); it started as a
three-employee company to provide plans production services to the Florida Department of Transportation (FDOT) eight
offices. Currently we are multi-disciplinary, consulting engineering firm with our headquarters located in the City of
Doral. A&P specializes in roadway design, traffic and transportation engineering, water resources and wastewater
disposal, civil site planning and design, electrical and mechanical engineering design for commercial and industrial
projects, structural design, ITS design, construction management, and construction engineering and inspection (CEI)
services. Today we have ninety-five (98) employees of which sixty-four (64) are graduate civil engineers. Thirty (30) of
our engineers are registered in the State of Florida. The primary markets that our firm serves are governmental agencies
in South Florida (Palm Beach, Broward, Miami and Monroe Counties). Our staff has a combined one-hundred (100) years
of experience working as employees of FDOT. Three of our engineers started working in FDOT in the Professional
Engineers Training Program, then worked as Project Engineers, Project managers, and later on transitioned to the
consultant world. Currently we have open contracts with District IV and VI offices of FDOT, Miami-Dade Water and
Sewer Department, Miami-Dade Department of Transportation and Public Works, Miami-Dade Expressway Authority,
and as sub-consultants with several other prominent engineering firms. We have also been recently selected by the City
of Doral, City of Miami Beach, and the City of Miami to provide services to their Capital Improvements Program.
The Traffic Engineering Department at A&P Engineers is committed to improve and ensure the safety of our roads and
pedestrian paths. Our senior staff brings over 25 years of experience to ensure the success of your next transportation
safety project. We collaborate with government agencies to develop municipal, county, district, and state-wide projects
and programs. Our department has been involved in over ten district-wide contracts and has conducted more than 80
studies and evaluations.
A&P prides itself in serving a wide variety of clients and attending their individual needs. Our firm is unparalleled in
client satisfaction, providing our clients with focused and innovative solutions that yield cost effective results. Since its
establishment A&P has competed a myriad of projects ranging in scale and complexity. The broad spectrum of award-
winning projects in our portfolio provides the diverse foundation necessary to overcome any challenge that may arise. It
is this diversity, innately found in our firm, which enables A&P to guarantee effective project execution for large-scale
federal projects while simultaneously delivering to our private and municipal clients the delicacy that is indispensable to
their particular needs.
I. AUTHORIZED REPRESENTATIVE
The foregoing is a statement of facts.
31. SIGNATURE
32. DATE December 10th , 2018
33. NAME AND TITLE
Antonio G. Acosta, P.E. - President
STANDARD FORM 330
ARCHITECT ENGINEER QUALIFICATIONS 1. SOLICITATION NUMBER (If any) RFQ-18-11-01
PART II - GENERAL QUALIFICATIONS
(If a firm has branch offices, complete for each specific branch office seeking work.)
2a. FIRM (OR BRANCH OFFICE) NAME A&P Consulting Transportation Engineers, Corp 3. YEAR ESTABLISHED 1995 4. DUNS NUMBER 00-933-5857
2b. STREET 10305 NW 41 Street, Suite 115 5. OWNERSHIP
a. TYPE Corporation 2c. CITY Doral 2d. STATE Florida 2e. ZIP CODE 33178 b. SMALL BUSINESS STATUS
6a. POINT OF CONTACT NAME AND TITLE Antonio G. Acosta, P.E. - President 7. NAME OF FIRM (If block 2a is a branch office)
6b. TELEPHONE NUMBER (305) 592-7283 6c. E-MAIL ADDRESS agacosta@apcte.com
8a. FORMER FIRM NAME(S) (If any) 8b. YR. ESTABLISHED 8c. DUNS
NUMBER
9. EMPLOYEES BY DISCIPLINE 10. PROFILE OF FIRM'S EXPERIENCE AND
ANNUAL AVERAGE REVENUE FOR LAST 5 YEARS
a. Function
Code b. Discipline
c. No. of Employees a. Profile
Code b. Experience
c. Revenue
Index
Number
(see below) (1) FIRM (2) BRANCH
02 Administrative 10 10 D04 Design-Build Preparation 7
08 CADD Technician 8 8 H07 Highways; Streets; Airfield 6
12 Civil Engineer 16 16 W02 Water Resources; Hydrology 5
15 Construction Inspector 25 25 T02 Traffic & Transportation Eng. 5
16 Construction Manager 5 5 C15 Construction Management 6
18 Cost Engineer / Estimator 1 1 C18 Cost Estimating / Engineering 2
21 Electrical Engineer 7 7 E02 Electrical Studies / Design 5
42 Mechanical Engineer 1 1
53 Scheduler 1 1
60 Transportation Engineer 10 10
62 Water Resources Engineer 14 14
Other Employees
Total 98 98
11. ANNUAL AVERAGE PROFESSIONAL
SERVICES REVENUES OF FIRM
FOR LAST 3 YEARS
(Insert revenue index number shown at right)
PROFESSIONAL SERVICES REVENUE INDEX NUMBER
1. Less than $100,000. 6. $2 million to less than $5 million
2. $100,00 to less than $250,000 7. $5 million to less than $10 million
3. $250,000 to less than $500,000 8. $10 million to less than $25 million
4. $500,000 to less than $1 million 9. $25 million to less than $50 million
5. $1 million to less than $2 million 10. $50 million or greater
a. Federal Work
b. Non-Federal Work 8
c. Total Work 8
12. AUTHORIZED REPRESENTATIVE
The foregoing is a statement of facts.
a. SIGNATURE
b. DATE December 10th , 2018
c. NAME AND TITLE Antonio G. Acosta, P.E. - President
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
27
APCTE has no variations nor execptions of the services which will not are not included in the firm’s proposal to the required services as outlined in the Scope of Services.
SECTION H - VARIATIONS | EXECPTIONS
A&P CONSULTING TRANSPORTATION ENGINEERS, CORP.
GOLDEN SHORES PUMP STATION REHABILITATION (CCNA)
RFQ 18-11-01
28
Neither the entity submitting this sworn statement, nor any of its officers, directors, executives, partners, shareholders,
employees, members, or agents who are active in the management of the entity, nor any affiliate of the entity has had
an incident within the last five (5) years where (a) a civil, criminal, administrative, other similar proceeding was filed or
is pending, if such proceeding arises from or is a dispute concerning the Proposer’s rights, remedies or duties under a
contract for the same or similar type services to be provided under this RFP.
SECTION I - LITIGATION STATEMENT
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 25
REQUIRED FORMS
PRIME FIRM
SUB-CONSULTANTS
Respondent intends to use the following sub-consultant on this project (if none, write “None”):
Role Name of Individual Assigned
to Project:
Role/Description of
Work:
Experience:
Name and address
of sub-consultant:
Name and address
of sub-consultant:
Role Name of Individual Assigned
to Project
Number of
Years’
Experience
Education,
Degree
Address of office:
Principle-in-
Charge:
Project
Manager
Asst.
Project
Manager
Other Key
Member
Other Key
Member
Other Key
Member
Antonio G. Acosta, P.E. 32 B.S. Civil Eng. 10305 NW 41 St. #115, Doral, Fl.
Arnelio Alfonso, P.E.32 B.S. Civil Eng. 10305 NW 41 St. #115, Doral, Fl.
Lazaro Ferrero, P.E.32 B.S. Civil Eng. 10305 NW 41 St. #115, Doral, Fl.
Angela Baron, P.E.10 B.S. Civil Eng. 10305 NW 41 St. #115, Doral, Fl.
Eduardo Martinez, P.E.39 B.S. Elect. Eng. 10305 NW 41 St. #115, Doral, Fl.
Osmany Alfonso, P.E.22 B.S. Civil Eng. 10305 NW 41 St. #115, Doral, Fl.
Longitude Surveyors, LLC
7715 NW 48 Street,
Suite 310
Doral, FL 33166
Surveying and SUE Established in 2004 to
provide surveying and
mapping services
Nadic Engineering Services, Inc.
601 N. Hart Blvd.
Orlando, Florida 32818
Geotechnical Established in 2001 as a
full service consulting
geotechnical, water
resources, & construction
material testing
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 26
Name and address
of sub-consultant:
Name and address
of sub-consultant:
Name and address
of sub-consultant:
Name and address
of sub-consultant:
Please use additional pages if needed.
REFERENCES
Name Entity Providing
Reference
Phone # Email Address
Luis Soto, P.E.City of Miami Beach 305-673-7000 Ext: 6924 luissoto@miamibeachfl.gov
Rolando M. Roque, P.E. M-D Water and Sewer Dept. 786-552-8129 roquer@miamidade.gov
Elsa Riverol, P.E.FDOT District 6 305-470-5105 elsa.riverol@dot.state.fl.us
Orlando Misas City of Miami 305-416-1038 omisas@miamigov.com
Gil Portela, P.E.MDX GEC A - HNTB 305-551-8100 gportela@hntb.com
Media Relations Group, LLC
18001 Old Cutler Road
Suite 459
Palmetto Bay, FL 33157
Public Information
Specialist/Business
Development Manager
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 27
PROJECT VERIFICATION FORM
Respondent must have completed the design and permitting of at least two (2) pump station projects in
the past ten (10) years. The completed projects meeting this minimum qualification may have been
performed by the individual, firm, or project manager assigned to the Work.
1)Name of Client Entity: ______________________________________________
Address: __________________________________________________________
City/State/Zip: ______________________________________________________
Contact: __________________________________________________________
Title: _____________________________________________________________
Email Address:____________________________________________________
Telephone: ________________________________________________________
Scope of Work: _____________________________________________________
Contract Start/End Dates: _____________________________________________
Consultant Contract Amount: $_________________________________________
2)Name of Client Entity: ______________________________________________
Address: __________________________________________________________
City/State/Zip: ______________________________________________________
Contact: __________________________________________________________
Title: _____________________________________________________________
Email Address:____________________________________________________
Telephone: ________________________________________________________
Scope of Work: _____________________________________________________
Contract Start/End Dates: _____________________________________________
Consultant Contract Amount: $_________________________________________
3)Name of Client Entity: ______________________________________________
Address: __________________________________________________________
City/State/Zip: ______________________________________________________
Contact: __________________________________________________________
Title: _____________________________________________________________
____________________
END OF SECTION
City of Miami Beach
City of Miami Beach
Miami-Dade Water & Sewer Deparetment
Public Works Department, 1700 Convention Center Drive
Public Works Department, 1700 Convention Center Drive
3071 SW 38th Avenue
Miami Beach, Florida 33139
Miami Beach, Florida 33139
Luis Soto, P.E.
Luis Soto, P.E.
Assistant City Engineer
Assistant City Engineer
luissoto@miamibeachfl.gov
luissoto@miamibeachfl.gov
305-673-7000 Ext: 6924
May 2016 to May 2018
Design of a 80.000 GPM Stormwater Pump Station
450,000.00
Miami, Florida 33146
Rolando M. Roque, P.E.
Pump Station Compliance Section Chief
roquer@miamidade.gov
786-552-8129
Design of the rehabilitation of Pump Station PS 437 and PS 351
April 2015 to Dec. 2016
187.000.00
Email Address:__ _______________________________
Telephone: __________305-673-7000 Ext: 6924______________________________________________
Scope of Work: __________________Design of a 24.000 GPM Stormwater Pump Station__________________________________
Contract Start/End Dates: __________Dec 2014 to Oct 2015___________________________________
Consultant Contract Amount: $_______345,000.00__________________________________
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 28
DELIVER TO:
City of Sunny Isles Beach
City Clerk
18070 Collins Avenue, 4th Floor
Sunny Isles Beach, FL 33160
REQUEST FOR
QUALIFICATIONS
SECTION 6
RESPONDENT SUBMITTAL
FORMS
OPENING: 2:30 P.M.
Wednesday, November 28, 2018
NOTE: City of Sunny Isles Beach is exempt from all taxes (Federal, State, and Local). Tax Exemption
Certificate furnished upon request.
Issued by: Purchasing Agent
Genesis Cuevas
Date issued:
11/5/2018
This Qualification Submittal
Consists of all required forms,
including SF330, Questionnaires,
Acknowledgements and Affidavits
Submissions are subject to the Terms and Conditions of this Request for Qualifications and the
accompanying Submittal. Such other contract provisions, specifications, drawings or other data as are
attached or incorporated by reference in the Submittal, will be received at the office of the City Clerk at the
address shown above until the above stated time and date, and at that time, publicly opened for furnishing
services described in the accompanying Submittal Requirement.
RFQ No. 18-11-01
CONSULTING ENGINEERING SERVICES FOR GOLDEN SHORES PUMP STATION
REHABILITATION (CCNA)
Firm Name
________________________________________ Commodity Code(s):
RETURN ONE ORIGINAL AND FOUR COPIES OF QUALIFICATION SUBMITTAL PAGES AND
AFFIDAVITS
FAILURE TO SIGN PAGE 31 OF SECTION 6 QUALIFICATION SUBMITTAL WILL RENDER YOUR
SUBMISSION NON-RESPONSIVE
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 29
RESPONDENT SUBMITTAL FORM:
ACKNOWLEDGEMENT OF ADDENDA
INSTRUCTIONS: COMPLETE PART I OR PART II, WHICHEVER APPLIES
PART I:
LIST BELOW ARE THE DATES OF ISSUE FOR EACH ADDENDUM RECEIVED IN CONNECTION
WITH THIS RFQ
Addendum #1, Dated
Addendum #2, Dated
Addendum #3, Dated
Addendum #4, Dated
Addendum #5, Dated
Addendum #6, Dated
Addendum #7, Dated
Addendum #8, Dated
PART II:
NO ADDENDUM WAS RECEIVED IN CONNECTION WITH THIS RFQ
FIRM NAME:
AUTHORIZED SIGNATURE:DATE:
TITLE OF OFFICER:
Antonio G. Acosta, P.E.
President
12/10/18
November 16, 2018
November 26, 2018
December 5, 2018
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 30
RESPONDENT SUBMITTAL FORM CONSULTING ENGINEERING SERVICES FOR GOLDEN
SHORES PUMP STATION REHABILITATION (CCNA)
The undersigned Firm proposes and agrees, if this submission is accepted, to enter into an agreement with
the City of Sunny Isles Beach to perform and furnish all Services as specified or indicated in the Contract
Documents.
The Firm accepts all of the terms and conditions of this Request for Qualifications. This RFQ will remain
subject to acceptance for 90 days after the day of RFQ opening. The Firms agrees to sign and submit the
Agreement and other documents as required by the Bidding Requirements within ten days after the date
of the City’s Notice of Award.
In submitting this response, the Firm represents, as more fully set forth in the Agreement, that:
The Firm has familiarized himself/herself with the nature and extent of the
Contract Documents, Work, site, locality, and all local conditions and Law and
Regulations that in any manner may affect cost, progress, performance, or
furnishing of the Work.
The Firm has studied carefully all reports and drawings of subsurface conditions
and drawings of physical conditions.
The Firm has given the City written notice of all conflicts, errors, discrepancies that
it has discovered in the Contract Documents and the written resolution thereof by
City is acceptable to the Firm.
This solicitation is genuine and not made in the interest of or on behalf of any
undisclosed person, firm or corporation and is not submitted in conformity with
any agreement or rules of any group, association, organization, or corporation;
the Firm has not directly or indirectly induced or solicited any other Firms to submit
a false or sham Bid; the Firm has not solicited or induced any person, firm or
corporation to refrain from Bidding; and Firm has not sought by collusion to obtain
for itself any advantage over any other Firms or over the City.
The City and the successful Firm will establish completion times for the services described in this Request
for Qualifications and the successful Firm agrees that the services will be completed within the time frames
agreed upon and stipulated in the individual Notice to Proceed.
City of Sunny Isles Beach |Request for Qualifications No. 18-11-01 31
Firm Name:
_____________________________________________________________________________
Street Address:
_____________________________________________________________________________
Mailing Address (if different):
_____________________________________________________________________________
Telephone No. _______________________________Fax No. _________________________
Email Address: _______________________________FEIN No. __/__-__/__/__/__/__/__/__
*By signing this document the Responder agrees to all Terms & Conditions of RFQ
Signature:
__________________________________________________________________
(Signature of authorized agent)
Print Name: ______________ ___________
Title: _________________________________________
Date:
THE EXECUTION OF THIS FORM CONSTITUTES THE UNEQUIVOCAL OFFER OF FIRM TO BE
BOUND BY THE TERMS OF ITS SUBMISSION. FAILURE TO SIGN THIS SOLICITATION WHERE
INDICATED ABOVE BY AN AUTHORIZED REPRESENTATIVE SHALL RENDER THE SUBMISSION
NON-RESPONSIVE. THE CITY MAY, HOWEVER, IN ITS SOLE DISCRETION, ACCEPT ANY
SUBMISSION THAT INCLUDES AN EXECUTED DOCUMENT, WHICH UNEQUIVOCALLY BINDS
THE FIRM TO THE TERMS OF ITS OFFER.
A&P Consulting Transportation Engineers, Corp.
10305 N.W. 41 Street, Suite 115, Doral, Florida 33178
305-592-7283 305-593-1594
info@apcte.com 6 5 0 7 7 0 5 8 3
Antonio G. Acosta, P.E.
President