Appendix C - AV Equipment Cut Sheets
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(19-01-01) Gateway Park Center
>
Appendix C - AV Equipment Cut Sheets
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 11:54:03 AM
Creation date
1/31/2019 11:45:46 AM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
282
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3 <br />DIP Switches <br />DIP Switch 6: RAW FEEDBACK—In the ON position, the <br />Programming Interface will report when a button has been <br />pushed or released on a GRAFIK Eye Control Unit or low-voltage <br />Accessory Control. This response varies depending on the type <br />of unit, as listed below: <br />GRAFIK Eye Control Units (GRX-3100/4100 and GRX-3500/ <br />4500 models) <br />Scene Selection Control (NTGRX-4S/4S-IR and EGRX-4S/ <br />4S-IR) <br />Architrave Door Jamb Control (GRX-4S-DW) <br />Infrared Ceiling Receiver (GRX-CIR) <br />A/V Interface Control (GRX-AV) <br />Infrared Wireless Remote Controls (GRX-IT & GRX-8IT) <br />The first parameter indicates the address of the Accessory <br />Control or Control Unit upon which the button was pushed or <br />released. A capital letter indicates a button was pushed, and a <br />lowercase letter indicates a button was released. The following is <br />a list of how addresses are indicated. <br />Unit: Addressed as: Indicated by: <br />Control Unit A1 A or a <br /> A2 B or b <br /> A3 C or c <br /> A4 D or d <br /> A5 E or e <br /> A6 F or f <br /> A7 G or g <br /> A8 H or h <br />Accessory Control 1 I or i <br /> 2 J or j <br /> 3 K or k <br /> 4 L or l <br /> 5 M or m <br /> 6 N or n <br /> 7 O or o <br /> 8 P or p <br /> 9 Q or q <br />10 R or r <br />11 S or s <br />12 T or t <br />13 U or u <br />14 V or v <br />15 W or w <br />16 X or x <br />The second parameter indicates the scene which was selected. If <br />the off button is pushed, it is indicated by a zero. A Master Raise is <br />indicated by an 18, and a Master Lower is indicated by a 19. <br />EXAMPLE of response: <br />D3<CR><LF> <br />The scene 3 button was pushed on GRAFIK Eye <br />Control Unit addressed as A4. <br />Two-Button Control (NTGRX-2B-SL) <br />The first parameter indicates the address as above. The second <br />parameter is a 1 to indicate that the Raise or top button has been <br />pushed and is a 0 to indicate that a Lower or bottom button has <br />been pushed. <br />The settings of the DIP switches affect the interface control between <br />GRAFIK Eye Control Units and your PC or auxiliary A/V equipment. <br />DIP switch options are described below: <br />DIP Switch 1: ZONE LOCK RETAIN <br />DIP Switch 2: SCENE LOCK RETAIN <br />DIP Switch 3: SEQUENCE RETAIN—In the event of a power <br />outage, the RS232 Interface will retain which GRAFIK Eye <br />Control Units were in ZONE LOCK, SCENE LOCK and <br />SEQUENCE (set using the GRX-RS232/GRX-PRG), respectively. <br />Upon returning power, Control Units that had been in Zone Lock, <br />Scene Lock, or Sequencing (set using the GRX-RS232/GRX- <br />PRG) will stay locked or sequencing if the DIP switches are in <br />the ON position. When these DIP switches are in the OFF <br />position, this information will not be restored upon power up. <br />These DIP switches do not affect Zone Lock, Scene Lock, or <br />Sequencing set by a GRX-AV in 4Q mode. <br />DIP Switch 4: SEQUENCE TYPE—Set the scene range that <br />GRAFIK Eye Control Units will sequence, using the SEQUENCE <br />command of the GRX-RS232/GRX-PRG. In the OFF position, <br />GRAFIK Eye Control Units will sequence scenes 1 through 4. In <br />the ON position, they will sequence scenes 5 through 16. <br />DIP Switch 5: FIXED ADDRESS (GRX-RS232 only)—If you <br />want to add a GRX-RS232 Interface to a MUX link that already <br />has a GRX-RS232 or GRX-PRG, the fixed address option must <br />be used by setting DIP Switch 5 ON. DIP Switches 1—4 are then <br />used to address the Interface. The Sequence Type (DIP switch 4) <br />that will run when using the SEQUENCE command of the GRX- <br />RS232/GRX-PRG is determined by the address of the GRX- <br />RS232/GRX-PRG. Even addresses (2, 4, . . . ) will sequence <br />scenes 1—4, and odd addresses (1, 3, . . . ) will sequence <br />scenes 5—16. Refer to the addressing table below. <br />* Reserved for GRX-PRG. <br />A fixed address GRX-RS232 unit can only do one of the <br />following 4Q functions at any time: Zone Lock (ZL), Scene Lock <br />(SL), and Sequencing (SQ). <br />Note:Use the fixed address option only if there is a GRX-PRG <br />or other GRX-RS232 already on the MUX link. <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />1 2 3 4 1 2 3 4 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15 <br />16* <br />Address Address
The URL can be used to link to this page
Your browser does not support the video tag.