Gateway Park Center PERKINS+WILL <br /> 810495.000 <br /> 12/06/18 <br /> <br /> <br />HOLLOW METAL DOORS AND FRAMES <br /> 08 11 13 - 7 <br /> <br /> <br />2. Floor Anchors: Provide floor anchors for each jamb and mullion that extends <br />to floor, and secure with postinstalled expansion anchors. <br />a. Floor anchors may be set with power-actuated fasteners instead of <br />postinstalled expansion anchors if so indicated and approved on Shop <br />Drawings. <br />3. Metal-Stud Partitions: Solidly pack mineral -fiber insulation inside frames. <br />4. Masonry Walls: Coordinate installation of frames to allow for solidly filling <br />space between frames and masonry with grout. <br />5. In-Place Concrete or Masonry Construction: Secure frames in place with <br />postinstalled expansion anchors. Countersink anchors, and fill and make <br />smooth, flush, and invisible on exposed faces. <br />6. Installation Tolerances: Adjust hollow-metal door frames for squareness, <br />alignment, twist, and plumb to the following tolerances: <br />a. Squareness: Plus or minus 1/16 inch, measured at door rabbet on a line <br />90 degrees from jamb perpendicular to frame head. <br />b. Alignment: Plus or minus 1/16 inch, measured at jambs on a horizontal <br />line parallel to plane of wall. <br />c. Twist: Plus or minus 1/16 inch, measured at opposite face corners of <br />jambs on parallel lines, and perpendicular to plane of wall. <br />d. Plumbness: Plus or minus 1/16 inch, measured at jambs at floor. <br />C. Hollow-Metal Doors: Fit hollow-metal doors accurately in frames, within clearances <br />specified below. Shim as necessary. <br />1. Non-Fire-Rated Steel Doors: <br />a. Between Door and Frame Jambs and Head: 1/8 inch plus or minus 1/32 <br />inch. <br />b. Between Edges of Pairs of Doors: 1/8 inch to 1/4 inch plus or minus <br />1/32 inch. <br />c. At Bottom of Door: 5/8 inch plus or minus 1/32 inch. <br />d. Between Door Face and Stop: 1/16 inch to 1/8 inch plus or minus 1/32 <br />inch. <br />D. Glazing: Comply with installation requirements in Section 08 80 00 "Glazing" and <br />with hollow-metal manufacturer's written instructions. <br />1. Secure stops with countersunk flat- or oval-head machine screws spaced <br />uniformly not more than 9 inches o.c. and not more than 2 inches o.c. from <br />each corner. <br />3.4 ADJUSTING AND CLEANING <br />A. Final Adjustments: Check and readjust operating hardware items immediately <br />before final inspection. Leave work in complete and proper operating condition. <br />Remove and replace defective work, including hollow-metal work that is warped, <br />bowed, or otherwise unacceptable.
The URL can be used to link to this page
Your browser does not support the video tag.