My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Gateway Park Technical Specs Volume 1 (3)
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(19-01-01) Gateway Park Center
>
Gateway Park Technical Specs Volume 1 (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2019 1:53:00 PM
Creation date
1/31/2019 1:35:01 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
724
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Gateway Park Center PERKINS+WILL <br /> 810495.000 <br /> 12/06/18 <br /> <br /> <br />VISUAL DISPLAY FABRICS <br /> 10 11 46 - 1 <br /> <br /> <br />SECTION 10 11 46 - VISUAL DISPLAY FABRICS <br />PART 1 - GENERAL <br />1.1 SUMMARY <br />A. Section includes tackable wall coverings. <br />1.2 ACTION SUBMITTALS <br />A. Product Data: For each type of tackable wall covering. Include data on physical <br />characteristics, durability, and flame-resistance characteristics. <br />B. Shop Drawings: Show location and extent. <br />C. Samples: For each type of tackable wall covering and trim. <br />1.3 CLOSEOUT SUBMITTALS <br />A. Maintenance Data: For tackable wall coverings to include in maintenance manuals. <br />1.4 FIELD CONDITIONS <br />A. Environmental Limitations: Do not deliver or install tackable wall coverings until <br />spaces are enclosed and weathertight, wet-work in spaces is complete and dry, <br />work above ceilings is complete, and temporary HVAC system is operating and <br />maintaining ambient temperature and humidity conditions at occupancy levels <br />during the remainder of the construction period. <br />PART 2 - PRODUCTS <br />2.1 PERFORMANCE REQUIREMENTS <br />A. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified <br />testing agency. Identify products with appropriate markings of applicable testing <br />agency. <br />1. Flame-Spread Index: 25 or less. <br />2. Smoke-Developed Index: 50 or less. <br />2.2 WC-1, TACKABLE WALL COVERINGS <br />A. Basis-of-Design Product: Subject to compliance with requirements, provide product <br />indicated on Drawings or comparable product acceptable to the Architect.
The URL can be used to link to this page
Your browser does not support the video tag.