Laserfiche WebLink
<br />E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT (Complete one Section E for each key person) <br />12. NAME 13. ROLE IN THIS <br />CONTRACT 14. YEARS EXPERIENCE <br />Antonio Diaz SUR SUE Technician 3 Senior <br /> a. TOTAL 22 b. WITH CURRENT FIRM 22 <br />15. FIRM NAME AND LOCATION (City and State) F.R. Aleman & Associates, Inc. (Miami, FL) <br />16. EDUCATION (DEGREE AND SPECIALIZATION) <br /> <br /> 17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE) Florida Intermediate Training-ATSSA (FL) <br />18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.) <br /> Certified Scuba Diver, WorkZone Traffic Control Intermediate Level, Confined Space Entry Training Program <br /> <br />19. RELEVANT PROJECTS <br />a. (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> FDOT D4, Continuing Services for Surveying, Mapping and SUE (Fort Lauderdale, FL) PROFESSIONAL <br />SERVICES CONSTRUCTION (If applicable) <br />2023 N/A <br /> (3) BRIEF DESCRIPTION (Brief scope size, cost, etc.) AND SPECIFIC ROLE  Check if project performed with current firm <br />FRA was awarded this contract as prime consultant. Under this contract, FRA provided miscellaneous surveying and SUE services throughout Broward, Palm Beach, <br />Martin, Indian River, and St. Lucie Counties. The underground component was significant, with more than 20 of the total 70 task work orders involving some type of <br />underground utility investigation. Mr. Diaz has performed as SUE Technician on almost every project for this contract. <br />b. (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> FDOT D6, Districtwide Utility Location (2 Consecutive Contracts) <br />(Miami, FL) <br />PROFESSIONAL <br />SERVICES CONSTRUCTION (If applicable) <br />2017 N/A <br /> (3) BRIEF DESCRIPTION (Brief scope size, cost, etc.) AND SPECIFIC ROLE  Check if project performed with current firm <br />FRA served as the Prime consultant for this contract. FRA provided all the necessary services to designate, locate by excavating, survey, and map the existing surface <br />and subsurface utilities to support the design of construction plans on projects selected by the Department. FRA provided exact horizontal and vertical locations of <br />the existing underground utilities by way of electromagnetic and other geophysical location techniques including vacuum excavation. FRA facilitated a quick response <br />to the Department when ordering subsurface exploration services. The client benefits by receiving SUE data which enables them to identify, address and remedy <br />potential utility conflicts during the project’s design phase. The project length is 1,500 miles. Mr. Diaz served as SUE Technician. <br />c (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> <br />FDOT D4, I-595 Corridor Roadway Improvements, Design-Build (Broward County, FL) <br />PROFESSIONAL <br />SERVICES CONSTRUCTION (If applicable) <br />2011 N/A <br /> (3) BRIEF DESCRIPTION (Brief scope size, cost, etc.) AND SPECIFIC ROLE  Check if project performed with current firm <br />This project was the winner of the People’s Choice Award in the 2015 America's Transportation Awards competition. This $1.2 billion project relieved traffic congestion <br />and created a multimodal transportation network along I-595 in South Florida. FRA provided SUE services to support the design and construction for 15.5 miles of the <br />interstate highway system. FRA’s designation of all requested underground utilities by means of electromagnetic and GPR. In addition, we provided utility locations <br />using the vacuum excavation method for 1,500 possible utility conflicts. Our in-house surveying group is providing the necessary survey support, so we may deliver a <br />stand-alone product certified by a Professional Land Surveyor. The schedule of this project was very demanding, FRA was required to complete all required SUE <br />work within the first six months of the design. We completed all work on-time! <br />d. (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> City of Miami Beach, Topographic Survey and SUE for 11th Street (Miami Beach, FL) <br />PROFESSIONAL <br />SERVICES CONSTRUCTION (If applicable) <br />2017 N/A <br /> (3) BRIEF DESCRIPTION (Brief scope size, cost, etc.) AND SPECIFIC ROLE ☐ Check if project performed with current firm <br />As a subconsultant to A & P Consulting Transportation Engineer, FRA provided miscellaneous survey and SUE services along 11th Street in Miami Beach. Services <br />included topographic survey, underground utility survey, and SUE related work. Mr. Diaz served as Lead SUE Technician project providing designation of the <br />underground utilities. <br />e. (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> FDOT District 1, Districtwide Subsurface Utility Designating, Locating & Utility Coordination Support PROFESSIONAL <br />SERVICES CONSTRUCTION (If applicable) <br />2017 N/A <br /> (3) BRIEF DESCRIPTION (Brief scope size, cost, etc.) AND SPECIFIC ROLE Check if project performed with current firm <br />FRA was selected as Prime consultant and is providing all necessary services to designate and locate existing surface and subsurface utilities to support the design <br />of complete right-of-way and construction plans on a districtwide basis on projects selected by the Department. FRA also provides survey support and Utility <br />Coordination services. Mr. Diaz served as Lead SUE Technician. <br />